Okhwa Hwang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Okhwa Hwang has a total of 54 co-authors. Here are the top co-authors by number of shared publications:
- Junsu Park
Animal Environment Division, National Institute of Animal Science, 1500 Kongjwipatjwi-ro, Iseo-myeon, Wanju-gun 55365, Republic of Korea
7 shared publications - Siyoung Seo
National Institute of Animal Science, Wanju, Korea
5 shared publications - Min-Woong Jung
Senior Researcher, Animal Environment Division, National Institute of Animal Science, RDA, 1500 Kongjwipatjwi-ro, Iseo-myeon, Wanju-gun, Jeollabuk-do, 55365, Republic of Korea
4 shared publications - Saem-Ee Woo
Animal Environment Division National Institute of Animal Science
4 shared publications - Soyean Park
Animal Environment Division, Department of Animal Biotechnology and Environment, National Institute of Animal Science (NIAS), Rural Development Administration (RDA), Wanju-gun, Jeonju 55365, Republic of Korea
4 shared publications - Gwanggon Jo
Monitoring and Analysis Division, Geum River Basin Environment Office, Ministry of Environment (ME), Daejeon-si 34142, Republic of Korea
3 shared publications
Latest Publications
- Open Access
- 1 May 2026
- Published by Korean Society of Environmental Engineering in Journal of Korean Society of Environmental Engineers
- Vol. 48 (5) , 104-117
Evaluation of Ammonia Emission Reduction Performance and Scrubbing Water Replacement timing of a Wet Scrubber under Different Exhaust Fan Operating Rate in a Swine Barn
The performance of a wet scrubber is influenced by ammonia loading associated with changes in swine barn ventilation rate and the timing of scrubbing water replacement; however, studies evaluating these factors under field-operating conditions remain limited. In this study, a water-based wet scrubber installed in a mechanically ventilated enclosed swine barn was evaluated under four ventilation fan operation rates, 30%, 50%, 70%, and 100%, simulating seasonal ventilation conditions. The basic performance, ammonia emission reduction efficiency, and changes in scrubbing water characteristics were assessed. Ammonia concentrations at the inlet and outlet air of the wet scrubber were continuously measured over 14 days for each condition, and ammonia emissions were calculated based on measured ventilation rates. As a result, the L/G ratio ranged from 0.72 to 2.23L/m³, which was within the recommended range reported in previous studies. The ammonia emission reduction efficiencies at exhaust fan operating rates of 30%, 50%, 70%, and 100% were 40.75%, 52.09%, 57.90%, and 60.58%, respectively. And the concentrations of ammonium nitrogen and electrical conductivity (EC) in the scrubbing water increased over the operation period, with the highest values observed under the 100% fan operation condition. Electrical conductivity showed potential as a practical indicator of scrubbing water condition, and its saturation indicates a reduced capacity for ammonia absorption. Based on the EC saturation observed on day 11 under the 100% fan operation condition, the replacement timing of scrubbing water for other fan operation rates was estimated. The results indicated that saturation would respectively occur after an additional 35, 37, and 9 days at exhaust fan operating rates of 30%, 50%, and 70% beyond the 14-day experimental period for the respective conditions. This study quantified the ammonia emission reduction performance of a wet scrubber under varying ventilation conditions based on ammonia emission rates and proposed a method for estimating scrubbing water replacement timing using EC saturation levels. These findings provided practical implications for decision-making in scrubbing water management to maintain wet scrubber performance under field conditions.
- 1 May 2026
- Published by Korean Society of Environmental Engineering in Journal of Korean Society of Environmental Engineers
- Vol. 48 (5) , 104-117
Open AccessEvaluation of Ammonia Emission Reduction Performance and Scrubbing Water Replacement timing of a Wet Scrubber under Different Exhaust Fan Operating Rate in a Swine Barn
The performance of a wet scrubber is influenced by ammonia loading associated with changes in swine barn ventilation rate and the timing of scrubbing water replacement; however, studies evaluating these factors under field-operating conditions remain limited. In this study, a water-based wet scrubber installed in a mechanically ventilated enclosed swine barn was evaluated under four ventilation fan operation rates, 30%, 50%, 70%, and 100%, simulating seasonal ventilation conditions. The basic performance, ammonia emission reduction efficiency, and changes in scrubbing water characteristics were assessed. Ammonia concentrations at the inlet and outlet air of the wet scrubber were continuously measured over 14 days for each condition, and ammonia emissions were calculated based on measured ventilation rates. As a result, the L/G ratio ranged from 0.72 to 2.23L/m³, which was within the recommended range reported in previous studies. The ammonia emission reduction efficiencies at exhaust fan operating rates of 30%, 50%, 70%, and 100% were 40.75%, 52.09%, 57.90%, and 60.58%, respectively. And the concentrations of ammonium nitrogen and electrical conductivity (EC) in the scrubbing water increased over the operation period, with the highest values observed under the 100% fan operation condition. Electrical conductivity showed potential as a practical indicator of scrubbing water condition, and its saturation indicates a reduced capacity for ammonia absorption. Based on the EC saturation observed on day 11 under the 100% fan operation condition, the replacement timing of scrubbing water for other fan operation rates was estimated. The results indicated that saturation would respectively occur after an additional 35, 37, and 9 days at exhaust fan operating rates of 30%, 50%, and 70% beyond the 14-day experimental period for the respective conditions. This study quantified the ammonia emission reduction performance of a wet scrubber under varying ventilation conditions based on ammonia emission rates and proposed a method for estimating scrubbing water replacement timing using EC saturation levels. These findings provided practical implications for decision-making in scrubbing water management to maintain wet scrubber performance under field conditions.
- 31 December 2025
- Published by Korean Society for Atmospheric Environment in Journal of Korean Society for Atmospheric Environment
- Vol. 41 (6) , 988-1002
Effect of Benzoic Acid-Supplemented Diets on Ammonia Emission Reduction its Determinants in Pig Barn
- 31 December 2025
- Published by Korean Society for Atmospheric Environment in Journal of Korean Society for Atmospheric Environment
- Vol. 41 (6) , 988-1002
Effect of Benzoic Acid-Supplemented Diets on Ammonia Emission Reduction its Determinants in Pig Barn
- 28 February 2025
- Published by Korean Society for Atmospheric Environment in Journal of Korean Society for Atmospheric Environment
- Vol. 41 (1) , 104-112
Evaluation of the Effectiveness of Bio-curtains for Ammonia Removal in Pig Facility
- 28 February 2025
- Published by Korean Society for Atmospheric Environment in Journal of Korean Society for Atmospheric Environment
- Vol. 41 (1) , 104-112
Evaluation of the Effectiveness of Bio-curtains for Ammonia Removal in Pig Facility
- 21 April 2024
- Published by Elsevier in Journal of Environmental Management
- Vol. 358, 120884
Effects of swine manure dilution with lagoon effluent on microbial communities and odor formation in pit recharge systems
- 21 April 2024
- Published by Elsevier in Journal of Environmental Management
- Vol. 358, 120884
Effects of swine manure dilution with lagoon effluent on microbial communities and odor formation in pit recharge systems
- Open Access
Evaluation of Actual Ventilation Rates and Efficiency in Research-Scale Pig Houses Based on Ventilation Configurations
Accurate ventilation control is crucial for maintaining a healthy and productive environment in research-specialized pig facilities. This study aimed to evaluate actual ventilation rates and ventilation efficiency by investigating different inlet and exhaust configurations. The research was conducted in two pig rooms, namely pig room A and pig room B, in the absence of animals and workers to focus solely on evaluating the ventilation system’s performance. Actual ventilation rates were measured using hood-type anemometers, and the local air change per hour was analyzed at various measurement points via tracer gas decay experiments. The results demonstrated that specific inlet and exhaust combinations, such as side inlet/chimney outlet and ceiling inlet/side outlet, exhibited higher ventilation rates. However, the measured ventilation rates were much lower than the manufacturer’s specifications. The side exhaust fan closer to the pig activity space demonstrated better ventilation effectiveness for the animals than the chimney exhaust fan. Additionally, the ceiling inlet exhibited superior air distribution and uniformity. Lower ventilation rates and higher infiltration ratios resulted in reduced ventilation efficiency, with the difference between pig and worker activity spaces being pronounced. This study emphasizes the importance of selecting optimal inlet and exhaust configurations to achieve efficient ventilation and create a healthy environment for both pigs and workers.
Open AccessEvaluation of Actual Ventilation Rates and Efficiency in Research-Scale Pig Houses Based on Ventilation Configurations
Accurate ventilation control is crucial for maintaining a healthy and productive environment in research-specialized pig facilities. This study aimed to evaluate actual ventilation rates and ventilation efficiency by investigating different inlet and exhaust configurations. The research was conducted in two pig rooms, namely pig room A and pig room B, in the absence of animals and workers to focus solely on evaluating the ventilation system’s performance. Actual ventilation rates were measured using hood-type anemometers, and the local air change per hour was analyzed at various measurement points via tracer gas decay experiments. The results demonstrated that specific inlet and exhaust combinations, such as side inlet/chimney outlet and ceiling inlet/side outlet, exhibited higher ventilation rates. However, the measured ventilation rates were much lower than the manufacturer’s specifications. The side exhaust fan closer to the pig activity space demonstrated better ventilation effectiveness for the animals than the chimney exhaust fan. Additionally, the ceiling inlet exhibited superior air distribution and uniformity. Lower ventilation rates and higher infiltration ratios resulted in reduced ventilation efficiency, with the difference between pig and worker activity spaces being pronounced. This study emphasizes the importance of selecting optimal inlet and exhaust configurations to achieve efficient ventilation and create a healthy environment for both pigs and workers.
- 30 June 2023
- Published by The Korean Society of Climate Change Research in Journal of Climate Change Research
- Vol. 14 (3) , 337-347
A study on greenhouse gas emission characteristics of sow house with forced ventilation system during spring and summer
This study was conducted in three similar-structured pig rooms for approximately 160 days from March 25 to August 31, 2021 to investigate greenhouse gas emissions and characteristics emitted from sow housing with forced ventilation systems. Greenhouse gas emissions and coefficients were calculated by real-time measurement of greenhouse gas (Nitrous Oxide, Methane) concentrations, ventilation rate, and inside temperature and humidity in a pig house based on the mega chamber method, which assumes a closed pig room in the form of a chamber. The average concentration of Nitrous Oxide (N₂O) in each room was in the range of 0.5 to 0.6 ppm, and Methane (CH₄) concentration was in the range of 28.9 to 33.5 ppm. The average N₂O emissions from Rooms 1 to 3 were 4.7 ± 1.4, 4.5 ± 1.3, and 5.2 ± 1.6 mg/day·m²·pig. In the case of CH₄, average emissions were 86.0 ± 15.6, 100.2 ± 31.2, and 103.3 ± 26.7 mg/day·m² ·pig. Finally, greenhouse gas emissions from sows calculated in this study were 1.87 ± 0.6 g/year·m²·pig (N₂O) and 35.4 ± 8.8 g/year·m²·pig (CH₄). Greenhouse gas emission coefficients were calculated as carbon dioxide equivalent (COSUB2-eq/SUB) by applying Global Warming Potential (GWP) and were 1.38 g COSUB2-eq/SUB and 2.64 g COSUB2-eq/SUB for N₂O and CH₄, respectively. This suggests that the contribution of CH₄ is higher than that of N₂O emitted by sows. The results of this study present useful data for domestic emission coefficient research.
- 30 June 2023
- Published by The Korean Society of Climate Change Research in Journal of Climate Change Research
- Vol. 14 (3) , 337-347
A study on greenhouse gas emission characteristics of sow house with forced ventilation system during spring and summer
This study was conducted in three similar-structured pig rooms for approximately 160 days from March 25 to August 31, 2021 to investigate greenhouse gas emissions and characteristics emitted from sow housing with forced ventilation systems. Greenhouse gas emissions and coefficients were calculated by real-time measurement of greenhouse gas (Nitrous Oxide, Methane) concentrations, ventilation rate, and inside temperature and humidity in a pig house based on the mega chamber method, which assumes a closed pig room in the form of a chamber. The average concentration of Nitrous Oxide (N₂O) in each room was in the range of 0.5 to 0.6 ppm, and Methane (CH₄) concentration was in the range of 28.9 to 33.5 ppm. The average N₂O emissions from Rooms 1 to 3 were 4.7 ± 1.4, 4.5 ± 1.3, and 5.2 ± 1.6 mg/day·m²·pig. In the case of CH₄, average emissions were 86.0 ± 15.6, 100.2 ± 31.2, and 103.3 ± 26.7 mg/day·m² ·pig. Finally, greenhouse gas emissions from sows calculated in this study were 1.87 ± 0.6 g/year·m²·pig (N₂O) and 35.4 ± 8.8 g/year·m²·pig (CH₄). Greenhouse gas emission coefficients were calculated as carbon dioxide equivalent (COSUB2-eq/SUB) by applying Global Warming Potential (GWP) and were 1.38 g COSUB2-eq/SUB and 2.64 g COSUB2-eq/SUB for N₂O and CH₄, respectively. This suggests that the contribution of CH₄ is higher than that of N₂O emitted by sows. The results of this study present useful data for domestic emission coefficient research.
- Open Access
- 6 January 2023
- Published by MDPI AG in Atmosphere
- Vol. 14 (1) , 127
An Experimental Method for Evaluating Ammonia Emission Rates of Bio-Curtain
Bio-curtain (i.e., curtain) is a permeable cover equipped with a spraying system for ammonia (NH3) control in a swine facility. Previous studies investigated the NH3 reduction effects primarily based on concentration units. It is challenging to determine the actual efficiency because of the large amount of air discharged through the large surface of the curtain, and external wind rapidly dilutes and disperses the exhausted air. Therefore, this study investigates a technique to evaluate the NH3 reduction effect of the curtain in terms of emission rate. We constructed a metallic cover with a single hole around the curtain to gather the air discharged through it. The NH3 reduction effect was calculated by comparing the NH3 emission rate that was monitored in the barn exhaust fan and at the single hole of metallic cover during the non-spray and spray treatments inside the curtain at the maximum and minimum operating rate of the barn’s exhaust fan. NH3 emission rates declined both non-spray and spray at the minimum operation rate of the barn exhaust fan, but the reduction effect was higher in spray conditions than non-spray. Accumulating NH3-absorbed water inside the curtain under the low ventilation of the exhaust fan caused these circumstances.
- 6 January 2023
- Published by MDPI AG in Atmosphere
- Vol. 14 (1) , 127
Open AccessAn Experimental Method for Evaluating Ammonia Emission Rates of Bio-Curtain
Bio-curtain (i.e., curtain) is a permeable cover equipped with a spraying system for ammonia (NH3) control in a swine facility. Previous studies investigated the NH3 reduction effects primarily based on concentration units. It is challenging to determine the actual efficiency because of the large amount of air discharged through the large surface of the curtain, and external wind rapidly dilutes and disperses the exhausted air. Therefore, this study investigates a technique to evaluate the NH3 reduction effect of the curtain in terms of emission rate. We constructed a metallic cover with a single hole around the curtain to gather the air discharged through it. The NH3 reduction effect was calculated by comparing the NH3 emission rate that was monitored in the barn exhaust fan and at the single hole of metallic cover during the non-spray and spray treatments inside the curtain at the maximum and minimum operating rate of the barn’s exhaust fan. NH3 emission rates declined both non-spray and spray at the minimum operation rate of the barn exhaust fan, but the reduction effect was higher in spray conditions than non-spray. Accumulating NH3-absorbed water inside the curtain under the low ventilation of the exhaust fan caused these circumstances.
- 31 December 2022
- Published by Korean Society for Atmospheric Environment in Journal of Korean Society for Atmospheric Environment
- Vol. 38 (6) , 895-905
Comparison of Ammonia Emission Characteristics from Sows in Summer and Winter
- 31 December 2022
- Published by Korean Society for Atmospheric Environment in Journal of Korean Society for Atmospheric Environment
- Vol. 38 (6) , 895-905
Comparison of Ammonia Emission Characteristics from Sows in Summer and Winter