SPSoyean Park

Soyean Park

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Soyean Park has a total of 9 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • A study on greenhouse gas emission characteristics of sow house with forced ventilation system during spring and summer

    by Soyean Park, Yu-Na Jang, Gwanggon Jo, Min-Woong Jung, Siyoung Seo, Okhwa Hwang, Junsu Park

    This study was conducted in three similar-structured pig rooms for approximately 160 days from March 25 to August 31, 2021 to investigate greenhouse gas emissions and characteristics emitted from sow housing with forced ventilation systems. Greenhouse gas emissions and coefficients were calculated by real-time measurement of greenhouse gas (Nitrous Oxide, Methane) concentrations, ventilation rate, and inside temperature and humidity in a pig house based on the mega chamber method, which assumes a closed pig room in the form of a chamber. The average concentration of Nitrous Oxide (N₂O) in each room was in the range of 0.5 to 0.6 ppm, and Methane (CH₄) concentration was in the range of 28.9 to 33.5 ppm. The average N₂O emissions from Rooms 1 to 3 were 4.7 ± 1.4, 4.5 ± 1.3, and 5.2 ± 1.6 mg/day·m²·pig. In the case of CH₄, average emissions were 86.0 ± 15.6, 100.2 ± 31.2, and 103.3 ± 26.7 mg/day·m² ·pig. Finally, greenhouse gas emissions from sows calculated in this study were 1.87 ± 0.6 g/year·m²·pig (N₂O) and 35.4 ± 8.8 g/year·m²·pig (CH₄). Greenhouse gas emission coefficients were calculated as carbon dioxide equivalent (COSUB2-eq/SUB) by applying Global Warming Potential (GWP) and were 1.38 g COSUB2-eq/SUB and 2.64 g COSUB2-eq/SUB for N₂O and CH₄, respectively. This suggests that the contribution of CH₄ is higher than that of N₂O emitted by sows. The results of this study present useful data for domestic emission coefficient research.

  • Open Access

    An Experimental Method for Evaluating Ammonia Emission Rates of Bio-Curtain

    by Joshua Nizel Halder, Jun Su Park, So Yean Park, Kyeong Seok Kwon, Ok Hwa Hwang

    Bio-curtain (i.e., curtain) is a permeable cover equipped with a spraying system for ammonia (NH3) control in a swine facility. Previous studies investigated the NH3 reduction effects primarily based on concentration units. It is challenging to determine the actual efficiency because of the large amount of air discharged through the large surface of the curtain, and external wind rapidly dilutes and disperses the exhausted air. Therefore, this study investigates a technique to evaluate the NH3 reduction effect of the curtain in terms of emission rate. We constructed a metallic cover with a single hole around the curtain to gather the air discharged through it. The NH3 reduction effect was calculated by comparing the NH3 emission rate that was monitored in the barn exhaust fan and at the single hole of metallic cover during the non-spray and spray treatments inside the curtain at the maximum and minimum operating rate of the barn’s exhaust fan. NH3 emission rates declined both non-spray and spray at the minimum operation rate of the barn exhaust fan, but the reduction effect was higher in spray conditions than non-spray. Accumulating NH3-absorbed water inside the curtain under the low ventilation of the exhaust fan caused these circumstances.


  • Comparison of Ammonia Emission Characteristics from Sows in Summer and Winter

    by Soyean Park, Min-Woong Jung, Siyoung Seo, Saem-Ee Woo, Okhwa Hwang, Joshua Nizel Halder, Yuna Jang, Gwanggon Jo, Junsu Park


  • Estimation of Ammonia Emission Factors for a Mechanically-Ventilated Sow Facility in Fall

    by Soyean Park, Min-Woong Jung, Si-Young Seo, Saem-Ee Woo, Okhwa Hwang, Junsu Park

    Among the 316,299 tons of ammonia emissions in Korea, the highest emission is from livestock manure. Therefore, ammonia emission control in the pig industry is an urgent priority. In this study, the ammonia concentration of a mechanically-ventilation sow house and diurnal patterns were analyzed to calculate ammonia emission factors. This study was carried out for 91 days from September to November 2021 in a pig house located in Danyang, Chungcheongbuk-do. For repeated experiments, three pig rooms with the same environmental conditions were selected and monitored for the same period. The average ammonia concentration in each room was measured to be 11.09 ppm, 13.30 ppm, and 12.73 ppm, and the ventilation rates were 50.14, 61.88, and 66.82 m³/h/pig. The ammonia emission factor was 8.2 ± 1.3, 12.7 ± 2.7, and 12.8 ± 2.2 g/day/pig in rooms 1 to 3, respectively. In this study, the average value of 11.2 g/day/pig was calculated as the final ammonia emission factor for a sow house in fall.