MBMartin Bäumlein

Martin Bäumlein

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Martin Bäumlein has a total of 16 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Cement augmentation of an angular stable plate osteosynthesis for supracondylar femoral fractures - biomechanical investigation of a new fixation device

    by Martin Bäumlein, Antonio Klasan, Christine Klötzer, Benjamin Bockmann, Daphne Eschbach, Matthias Knobe, Benjamin Bücking, Steffen Ruchholtz, Christopher Bliemel

    Background: Implant anchorage in highly osteoporotic bone is challenging, since it often leads to osteosynthesis failure in geriatric patients with supracondylar femoral fractures. Cementation of screws is presumed to prevent such osteosynthesis failure. This study aimed to investigate the effect of a newly designed, cementable fenestrated condylar screw for plate fixation in a biomechanical setting. Methods: Eight pairs of osteoporotic cadaver femora with an average age of 77 years, ranging between 62 and 88 years, were randomly assigned to either an augmented or a non-augmented group. In both groups an instable 33-A3 fracture according to the AO / OTA classification was fixed with an angular stable locking plate. All right samples received a cement augmentation of their fenestrated condylar screws with calcium phosphate bone cement (CPC). Mechanical testing was performed at a load to failure mode by cyclic axial loading, using a servohydraulic testing machine. Results: With a mean of 2475 N (95% CI: 1727–3223 N), the pressure forces resulting in osteosynthesis failure were significantly higher in specimen with cemented condylar screws as compared to non-cemented samples (1875 N (95% CI: 1320–2430 N)) (p = 0.024). In both groups the deformation of the constructs, with the distal screws cutting through the condylar bone, were the most frequent cause for failure. Analysis of axial stiffness (p = 0.889) and irreversible deformity of the specimens revealed no differences between the both groups (p = 0.161). No cement leakage through the joint line or the medial cortex was observed. Conclusion: Based on the present study results, the newly introduced, cementable condylar screw could be an encouraging feature for the fixation of supracondylar femoral fractures in patients with reduced bone quality in terms of load to failure accuracy of the cement application.


  • Open Access

    Joint awareness in posttraumatic osteoarthritis of the knee: validation of the forgotten joint score in long term condition after tibial plateau fracture

    by Florian Baumann, Johannes Weber, Daniel Mahr, Martin Bäumlein, Maximilian Kerschbaum, Karolina Müller, Paavo Rillmann, Michael Nerlich, Markus Loibl

    Evaluating patient-reported outcomes (PRO) in early osteoarthritis (OA) of the knee is difficult. Established measurement tools are focused on one of the two major patient groups in knee surgery: young, highly active patients, or older patients with advanced degenerative OA of the knee. Joint awareness in everyday life is a crucial criterion in measuring PRO. The purpose of this study was to validate a German version of the “Forgotten Joint Score” (FJS) in patients after surgical treatment of tibial plateau fractures. In this prospective cohort study, clinical and radiological outcomes data were collected from patients after surgical treatment of tibial plateau fractures following a skiing accident. Functional outcome questionnaires were administered including the FJS, the Lysholm-Score, the Tegner-Activity Scale (TAS), the EuroQol-5D (EQ 5-D), and a subjective rating of change. The validation study was carried out according to the COSMIN checklist protocol. The KLS was used to measure the presence and severity of OA on knee radiographs, and correlation with the FJS was measured. Cronbach‘s alpha was .96 (95%-CI .92, .99) confirming good internal consistency. Test-retest reliability of the FJS was high with an ICC(67) = .91 (95%-CI .85,.95). Furthermore, no relevant floor or ceiling effects were observed. FJS significantly differed in patients with different OA degrees (p = .041). Symptomatic patients had significant lower FJS than asymptomatic patients (p < .001). This is the first study validating a disease-specific PRO, the FJS, in long-term outcomes after joint fracture. We demonstrated good psychometric properties and a significant correlation between the FJS and the radiologic degree of OA in patients with a history of tibial plateau fracture. Clinical Trial Registry University of Regensburg Z-2015-0872-2 . Registered 01. October 2015.