Trevor A. Snyder
Research Subjects
Trevor A. Snyder has a total of 130 co-authors. Here are the top co-authors by number of shared publications:
- William R. Wagner
Department of Bioengineering University of Pittsburgh Pittsburgh Pennsylvania USA
12 shared publications - David W. Schmidtke
Department of Bioengineering, University of Texas at Dallas, Richardson, TX 75080, USA
4 shared publications James W. Long
From the VADovations, Inc., Oklahoma City, OK
4 shared publicationsJoshua R. Woolley
Department of Bioengineering, Pittsburgh, PA, USA
4 shared publicationsKenneth N. Litwak
Department of Surgery, University of Louisville, Louisville, KY, USA; and
4 shared publicationsMarina V. Kameneva
From the *Levitronix LLC, Waltham, Massachusetts; Departments of †Bioengineering and ‡Surgery, Children’s Hospital of Pittsburgh, McGowan Institute for Regenerative Medicine, University of Pittsburgh, Pittsburgh, Pennsylvania; and §Levitronix GmBH, Zurich, Switzerland
4 shared publications
Latest Publications
- 3 August 2020
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 67 (2) , 214-219
Preclinical Device Thrombogenicity Assessments: Key Messages From the 2018 FDA, Industry, and Academia Forum
Device-related thrombosis and thromboembolic complications remain a major clinical concern and often impact patient morbidity and mortality. Thus, improved preclinical thrombogenicity assessment methods that better predict clinical outcomes and enhance patient safety are needed. However, there are several challenges and limitations associated with developing and performing preclinical thrombogenicity assessments on the bench and in animals (e.g., the clinical relevance of most in vitro tests has not been established, animal studies may not accurately predict clinical thrombotic events). To facilitate a discussion on how to overcome some of these challenges and to promote collaboration between the Food and Drug Administration (FDA), industry, and academia for the development of more reliable test methods, a scientific forum was organized by FDA and held in Washington, DC, on June 15, 2018 at the ASAIO 64th Annual Conference. Three subject matter experts from the medical device industry and FDA presented their perspectives at this forum, and several audience experts provided input during the open dialogue session. This article summarizes the key messages from the forum regarding the current status and challenges of preclinical thrombogenicity testing, important areas of needed research, and mechanisms for working with FDA to further improve thrombogenicity evaluations of medical devices.
- 3 August 2020
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 67 (2) , 214-219
Preclinical Device Thrombogenicity Assessments: Key Messages From the 2018 FDA, Industry, and Academia Forum
Device-related thrombosis and thromboembolic complications remain a major clinical concern and often impact patient morbidity and mortality. Thus, improved preclinical thrombogenicity assessment methods that better predict clinical outcomes and enhance patient safety are needed. However, there are several challenges and limitations associated with developing and performing preclinical thrombogenicity assessments on the bench and in animals (e.g., the clinical relevance of most in vitro tests has not been established, animal studies may not accurately predict clinical thrombotic events). To facilitate a discussion on how to overcome some of these challenges and to promote collaboration between the Food and Drug Administration (FDA), industry, and academia for the development of more reliable test methods, a scientific forum was organized by FDA and held in Washington, DC, on June 15, 2018 at the ASAIO 64th Annual Conference. Three subject matter experts from the medical device industry and FDA presented their perspectives at this forum, and several audience experts provided input during the open dialogue session. This article summarizes the key messages from the forum regarding the current status and challenges of preclinical thrombogenicity testing, important areas of needed research, and mechanisms for working with FDA to further improve thrombogenicity evaluations of medical devices.
- Open Access
- 19 December 2019
- Published by Springer Nature in Scientific Reports
- Vol. 9 (1) , 1-9
A Flow Induced Autoimmune Response and Accelerated Senescence of Red Blood Cells in Cardiovascular Devices
Red blood cells (RBCs) passing through heart pumps, prosthetic heart valves and other cardiovascular devices undergo early senescence attributed to non-physiologic forces. We hypothesized that mechanical trauma accelerates aging by deformation of membrane proteins to cause binding of naturally occurring IgG. RBCs isolated from blood of healthy volunteers were exposed to high shear stress in a viscometer or microfluidics channel to mimic mechanical trauma and then incubated with autologous plasma. Increased binding of IgG was observed indicating forces caused conformational changes in a membrane protein exposing an epitope(s), probably the senescent cell antigen of band 3. The binding of immunoglobulin suggests it plays a role in the premature sequestration and phagocytosis of RBCs in the spleen. Measurement of IgG holds promise as a marker foreshadowing complications in cardiovascular patients and as a means to improve the design of medical devices in which RBCs are susceptible to sublethal trauma.
- 19 December 2019
- Published by Springer Nature in Scientific Reports
- Vol. 9 (1) , 1-9
Open AccessA Flow Induced Autoimmune Response and Accelerated Senescence of Red Blood Cells in Cardiovascular Devices
Red blood cells (RBCs) passing through heart pumps, prosthetic heart valves and other cardiovascular devices undergo early senescence attributed to non-physiologic forces. We hypothesized that mechanical trauma accelerates aging by deformation of membrane proteins to cause binding of naturally occurring IgG. RBCs isolated from blood of healthy volunteers were exposed to high shear stress in a viscometer or microfluidics channel to mimic mechanical trauma and then incubated with autologous plasma. Increased binding of IgG was observed indicating forces caused conformational changes in a membrane protein exposing an epitope(s), probably the senescent cell antigen of band 3. The binding of immunoglobulin suggests it plays a role in the premature sequestration and phagocytosis of RBCs in the spleen. Measurement of IgG holds promise as a marker foreshadowing complications in cardiovascular patients and as a means to improve the design of medical devices in which RBCs are susceptible to sublethal trauma.
- 1 July 2019
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 65 (5) , 481-488
Benchtop von Willebrand Factor Testing: Comparison of Commercially Available Ventricular Assist Devices and Evaluation of Variables for a Standardized Test Method
Gastrointestinal bleeding occurs in 20–30% of patients receiving ventricular assist devices (VADs) due, in part, to acquired von Willebrand syndrome. We examined factors to optimize a benchtop method to quantify changes in von Willebrand Factor (VWF) multimer distribution and function in VADs, then applied them to evaluate commercially available devices. Human plasma was circulated through flow loops with VADs. Several experimental conditions were examined, including temperature, viscosity, and enzyme inhibition. Samples were analyzed for VWF collagen-binding activity (VWF:CB) and VWF antigen level. von Willebrand Factor multimer profiles were quantified using gel electrophoresis, near-infrared in-gel visualization, and densitometric analysis. The VWF:CB/antigen ratio in the HeartMate II, CentriMag, and HVAD exhibited average decreases of 46%, 44%, and 36% from baseline after 360 minutes of operation. High molecular weight (hVWF) multimer loss occurred within 30 minutes, although the Levacor and control loop profiles were unchanged. Varying temperature and viscosity altered hVWF degradation rate, but not the final results. Inhibition of a disintegrin and metalloprotease with thrombospondin type 1 repeats, member 13 (ADAMTS13) can potentially distinguish mechanoenzymatic cleavage of VWF from mechanical degradation. We developed a repeatable benchtop method to evaluate VWF compatibility of VADs similar to hemolysis testing that can be adopted for preclinical VAD evaluation.
- 1 July 2019
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 65 (5) , 481-488
Benchtop von Willebrand Factor Testing: Comparison of Commercially Available Ventricular Assist Devices and Evaluation of Variables for a Standardized Test Method
Gastrointestinal bleeding occurs in 20–30% of patients receiving ventricular assist devices (VADs) due, in part, to acquired von Willebrand syndrome. We examined factors to optimize a benchtop method to quantify changes in von Willebrand Factor (VWF) multimer distribution and function in VADs, then applied them to evaluate commercially available devices. Human plasma was circulated through flow loops with VADs. Several experimental conditions were examined, including temperature, viscosity, and enzyme inhibition. Samples were analyzed for VWF collagen-binding activity (VWF:CB) and VWF antigen level. von Willebrand Factor multimer profiles were quantified using gel electrophoresis, near-infrared in-gel visualization, and densitometric analysis. The VWF:CB/antigen ratio in the HeartMate II, CentriMag, and HVAD exhibited average decreases of 46%, 44%, and 36% from baseline after 360 minutes of operation. High molecular weight (hVWF) multimer loss occurred within 30 minutes, although the Levacor and control loop profiles were unchanged. Varying temperature and viscosity altered hVWF degradation rate, but not the final results. Inhibition of a disintegrin and metalloprotease with thrombospondin type 1 repeats, member 13 (ADAMTS13) can potentially distinguish mechanoenzymatic cleavage of VWF from mechanical degradation. We developed a repeatable benchtop method to evaluate VWF compatibility of VADs similar to hemolysis testing that can be adopted for preclinical VAD evaluation.
- 25 September 2018
- Published by Wiley in Artificial Organs
- Vol. 42 (12) , E427-E434
Assessment of Thrombelastography and Platelet Life Span in Ovines
Ovines are a common animal model for the study of cardiovascular devices, where consideration of blood biocompatibility is an essential design criterion. In the ovine model, tools to assess blood biocompatibility are limited and continued investigation to identify and apply additional assays is merited. Toward this end, the thrombelastograph, clinically utilized to assess hemostasis, was used to characterize normal ovine parameters. In addition, platelet labeling with biotin was evaluated for its potential applicability to quantify ovine platelet life span. Mean ovine thrombelastograph values were reaction‐time: 4.9 min,K‐time: 2 min, angle: 64.1°, maximum amplitude: 68.6mm, actual clot strength: 11.9 kd/s, and coagulation index: 1.5. Reaction time was significantly shorter and maximum amplitude, actual clot strength, and coagulation index were all significantly higher when compared to normal human thrombelastograph values suggesting some hypercoagulability of sheep blood. Biotinylation and reinfusion of ovine platelets allowed temporal tracking of the labeled platelet cohort with flow cytometry. These data indicated a mean ovine platelet life span of 188h with a half‐life of 84h. The collection of these parameters for normal ovines demonstrates the applicability of these techniques for subsequent studies where cardiovascular devices may be evaluated and provides an indication of normal ovine values for comparison purposes.
- 25 September 2018
- Published by Wiley in Artificial Organs
- Vol. 42 (12) , E427-E434
Assessment of Thrombelastography and Platelet Life Span in Ovines
Ovines are a common animal model for the study of cardiovascular devices, where consideration of blood biocompatibility is an essential design criterion. In the ovine model, tools to assess blood biocompatibility are limited and continued investigation to identify and apply additional assays is merited. Toward this end, the thrombelastograph, clinically utilized to assess hemostasis, was used to characterize normal ovine parameters. In addition, platelet labeling with biotin was evaluated for its potential applicability to quantify ovine platelet life span. Mean ovine thrombelastograph values were reaction‐time: 4.9 min,K‐time: 2 min, angle: 64.1°, maximum amplitude: 68.6mm, actual clot strength: 11.9 kd/s, and coagulation index: 1.5. Reaction time was significantly shorter and maximum amplitude, actual clot strength, and coagulation index were all significantly higher when compared to normal human thrombelastograph values suggesting some hypercoagulability of sheep blood. Biotinylation and reinfusion of ovine platelets allowed temporal tracking of the labeled platelet cohort with flow cytometry. These data indicated a mean ovine platelet life span of 188h with a half‐life of 84h. The collection of these parameters for normal ovines demonstrates the applicability of these techniques for subsequent studies where cardiovascular devices may be evaluated and provides an indication of normal ovine values for comparison purposes.
- 1 June 2018
- Published by Springer Nature in Cellular and Molecular Bioengineering
- Vol. 11 (4) , 279-290
Effects of Transient Exposure to High Shear on Neutrophil Rolling Behavior
Neutrophils display an array of behaviors ranging from rolling and migration to phagocytosis and granule secretion. Several of these behaviors are modulated by the local shear conditions. In the normal circulation, neutrophils experience shear rates from approximately 10–2000 s−1. However, neutrophils are also exposed to pathological shear levels in natural conditions such as severe stenosis and arteriosclerosis, as well as in blood-contacting devices such as ventricular assist devices and hemodialysis machines. The effects of transiently (< 1 s) exposing neutrophils to abnormally high shear rates (> 3000 s−1) are not well understood.
- 1 June 2018
- Published by Springer Nature in Cellular and Molecular Bioengineering
- Vol. 11 (4) , 279-290
Effects of Transient Exposure to High Shear on Neutrophil Rolling Behavior
Neutrophils display an array of behaviors ranging from rolling and migration to phagocytosis and granule secretion. Several of these behaviors are modulated by the local shear conditions. In the normal circulation, neutrophils experience shear rates from approximately 10–2000 s−1. However, neutrophils are also exposed to pathological shear levels in natural conditions such as severe stenosis and arteriosclerosis, as well as in blood-contacting devices such as ventricular assist devices and hemodialysis machines. The effects of transiently (< 1 s) exposing neutrophils to abnormally high shear rates (> 3000 s−1) are not well understood.
- 1 November 2017
- Published by AIP Publishing in Biomicrofluidics
- Vol. 11 (6) , 064105
Constricted microfluidic devices to study the effects of transient high shear exposure on platelets
Due to the critical roles that platelets play in thrombosis during many biological and pathological events, altered platelet function may be a key contributor to altered hemostasis, leading to both thrombotic and hemorrhagic complications. Platelet adhesion at arterial shear rates occurs through binding to von Willebrand Factor via the glycoprotein (GP) GPIb receptor. GPIb binding can induce platelet activation distinguishable by P-selectin (CD62P) surface expression and αIIbβ3 activation, resulting in platelet aggregation and formation of the primary hemostatic plug to stop bleeding. Previous studies have used cone and plate viscometers to examine pathologic blood flow conditions, applied shear rates that are relatively low, and examined exposure times that are orders of magnitude longer compared to conditions present in ventricular assist devices, mechanical heart valves, or pathologic states such as stenotic arteries. Here, we evaluate the effect of short exposure to high shear on granule release and receptor shedding utilizing a constricted microfluidic device in conjunction with flow cytometry and enzyme-linked immunosorbent assay. In this study, platelets were first perfused through microfluidic channels capable of producing shear rates of 80 000–100 000 s−1 for exposure times of 0–73 ms. We investigated platelet activation by measuring the expression level of CD62P (soluble and surface expressed), platelet factor 4 (PF4), and beta-thromboglobulin (βTG). In addition, we measured potential platelet receptor shedding of GPVI and GPIb using flow cytometry. The results showed that a single pass to high shear with short exposure times (milliseconds) had no effect on the levels of CD62P, GPVI and GPIb, or on the release of alpha granule content (PF4, βTG, and sP-selectin).
- 1 November 2017
- Published by AIP Publishing in Biomicrofluidics
- Vol. 11 (6) , 064105
Constricted microfluidic devices to study the effects of transient high shear exposure on platelets
Due to the critical roles that platelets play in thrombosis during many biological and pathological events, altered platelet function may be a key contributor to altered hemostasis, leading to both thrombotic and hemorrhagic complications. Platelet adhesion at arterial shear rates occurs through binding to von Willebrand Factor via the glycoprotein (GP) GPIb receptor. GPIb binding can induce platelet activation distinguishable by P-selectin (CD62P) surface expression and αIIbβ3 activation, resulting in platelet aggregation and formation of the primary hemostatic plug to stop bleeding. Previous studies have used cone and plate viscometers to examine pathologic blood flow conditions, applied shear rates that are relatively low, and examined exposure times that are orders of magnitude longer compared to conditions present in ventricular assist devices, mechanical heart valves, or pathologic states such as stenotic arteries. Here, we evaluate the effect of short exposure to high shear on granule release and receptor shedding utilizing a constricted microfluidic device in conjunction with flow cytometry and enzyme-linked immunosorbent assay. In this study, platelets were first perfused through microfluidic channels capable of producing shear rates of 80 000–100 000 s−1 for exposure times of 0–73 ms. We investigated platelet activation by measuring the expression level of CD62P (soluble and surface expressed), platelet factor 4 (PF4), and beta-thromboglobulin (βTG). In addition, we measured potential platelet receptor shedding of GPVI and GPIb using flow cytometry. The results showed that a single pass to high shear with short exposure times (milliseconds) had no effect on the levels of CD62P, GPVI and GPIb, or on the release of alpha granule content (PF4, βTG, and sP-selectin).
- 7 February 2017
- Published by Wiley in Artificial Organs
- Vol. 41 (10) , E129-E140
Flow‐Field Simulations and Hemolysis Estimates for the Food and Drug Administration Critical Path Initiative Centrifugal Blood Pump
The design of blood pumps for use in ventricular assist devices, which provide life‐saving circulatory support in patients with heart failure, require remarkable precision and attention to detail to replicate the functionality of the native heart. The United States Food and Drug Administration (FDA) initiated a Critical Path Initiative to standardize and facilitate the use of computational fluid dynamics in the study and development of these devices. As a part of the study, a simplified centrifugal blood pump model generated by computer‐aided design was released to universities and laboratories nationwide. The effects of changes in fluid rheology due to temperature, hematocrit, and turbulent flow on key metrics of the FDA pump were examined in depth using results from a finite volume‐based commercial computational fluid dynamics code. Differences in blood damage indices obtained using Eulerian and Lagrangian formulations were considered. These results are presented and discussed awaiting future validation using experimental results, which will be released by the FDA at a future date.
- 7 February 2017
- Published by Wiley in Artificial Organs
- Vol. 41 (10) , E129-E140
Flow‐Field Simulations and Hemolysis Estimates for the Food and Drug Administration Critical Path Initiative Centrifugal Blood Pump
The design of blood pumps for use in ventricular assist devices, which provide life‐saving circulatory support in patients with heart failure, require remarkable precision and attention to detail to replicate the functionality of the native heart. The United States Food and Drug Administration (FDA) initiated a Critical Path Initiative to standardize and facilitate the use of computational fluid dynamics in the study and development of these devices. As a part of the study, a simplified centrifugal blood pump model generated by computer‐aided design was released to universities and laboratories nationwide. The effects of changes in fluid rheology due to temperature, hematocrit, and turbulent flow on key metrics of the FDA pump were examined in depth using results from a finite volume‐based commercial computational fluid dynamics code. Differences in blood damage indices obtained using Eulerian and Lagrangian formulations were considered. These results are presented and discussed awaiting future validation using experimental results, which will be released by the FDA at a future date.
- 1 January 2017
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 63 (1) , 1-4
Mechanical Circulatory Support and Antithrombotic Therapy: Looking for the Holy Grail
- 1 January 2017
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 63 (1) , 1-4
Mechanical Circulatory Support and Antithrombotic Therapy: Looking for the Holy Grail
- 22 November 2016
- Published by Elsevier in The Journal of Thoracic and Cardiovascular Surgery
- Vol. 153 (6) , 1503-1506
Ventricular assist device thrombosis: Mind your P's & Q's—Pumps, patients, and pills
- 22 November 2016
- Published by Elsevier in The Journal of Thoracic and Cardiovascular Surgery
- Vol. 153 (6) , 1503-1506
Ventricular assist device thrombosis: Mind your P's & Q's—Pumps, patients, and pills
- 1 November 2013
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 59 (6) , 586-592
Postimplant Left Ventricular Assist Device Fit Analysis Using Three-Dimensional Reconstruction
Left ventricular assist devices (LVADs) are blood pumps that augment the function of the failing heart to improve perfusion, resulting in improved survival. For LVADs to effectively unload the left ventricle, the inflow cannula (IC) should be unobstructed and ideally aligned with the heart’s mitral valve (MV). We examined IC orientation deviation from a hypothesized conventional angle (45° right-posterior) and the approximate angle for direct IC-MV alignment in many patients. Three-dimensional anatomic models were created from computed tomography scans for 24 LVAD-implanted patients, and angles were measured between the IC and the apical z-axis in both the coronal and the sagittal planes. Common surgical IC angulation was found to be 22 ± 15° rightward and 21 ± 12° posterior from the apical z-axis; 38% (n = 9) of patients fell in this range. Direct IC-MV angulation was found to be 34 ± 8° rightward and 15 ± 7° posterior; only 8% (n = 2) of patients fell in this range. Rightward deviation toward ventricular septal wall and anterior deviation toward LV anterior freewall are associated with mortalities more so than leftward and posterior deviation. In conclusion, anatomic reconstruction may be a useful preoperative tool to obtain general population and patient-specific alignment for optimal LVAD implantation.
- 1 November 2013
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 59 (6) , 586-592
Postimplant Left Ventricular Assist Device Fit Analysis Using Three-Dimensional Reconstruction
Left ventricular assist devices (LVADs) are blood pumps that augment the function of the failing heart to improve perfusion, resulting in improved survival. For LVADs to effectively unload the left ventricle, the inflow cannula (IC) should be unobstructed and ideally aligned with the heart’s mitral valve (MV). We examined IC orientation deviation from a hypothesized conventional angle (45° right-posterior) and the approximate angle for direct IC-MV alignment in many patients. Three-dimensional anatomic models were created from computed tomography scans for 24 LVAD-implanted patients, and angles were measured between the IC and the apical z-axis in both the coronal and the sagittal planes. Common surgical IC angulation was found to be 22 ± 15° rightward and 21 ± 12° posterior from the apical z-axis; 38% (n = 9) of patients fell in this range. Direct IC-MV angulation was found to be 34 ± 8° rightward and 15 ± 7° posterior; only 8% (n = 2) of patients fell in this range. Rightward deviation toward ventricular septal wall and anterior deviation toward LV anterior freewall are associated with mortalities more so than leftward and posterior deviation. In conclusion, anatomic reconstruction may be a useful preoperative tool to obtain general population and patient-specific alignment for optimal LVAD implantation.