Juliana Batista Melo da Fonte
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Juliana Batista Melo da Fonte has a total of 42 co-authors. Here are the top co-authors by number of shared publications:
- Lucas Alves da Mota Santana
Federal University of Sergipe, Graduate Program in Dentistry, R. Cláudio Batista, Aracaju, 49060-108 Sergipe, SE, Brazil
4 shared publications - Saulo Leonardo Sousa Melo
College of Dentistry, Department of Oral Pathology, Radiology, and Medicine University of Iowa Iowa City Iowa USA
4 shared publications - Daniela Pita de Melo
College of Dentistry, University of Saskatchewan , Saskatoon, SK S7N 5E5
3 shared publications Lysandro Pinto Borges
Department of Pharmacy Federal University of Sergipe (UFS) São Cristóvão SE Brazil
3 shared publications- Ana Paula Piovezan Fugolin
School of Dentistry, Biomaterial and Biomedical Sciences, Oregon Health & Science University, USA
2 shared publications - Deborah Queiroz Freitas
Department of Oral Diagnosis, Piracicaba Dental School, University of Campinas, Piracicaba, Brazil
2 shared publications
Latest Publications
- 18 February 2026
- Published by Wiley in Oral Diseases
- Vol. 32 (8) , 2540-2541
Comment on: “Apremilast for Oral Mucosal‐Predominant Resistant Pemphigus Vulgaris: A Promising Adjunctive Treatment”
- 18 February 2026
- Published by Wiley in Oral Diseases
- Vol. 32 (8) , 2540-2541
Comment on: “Apremilast for Oral Mucosal‐Predominant Resistant Pemphigus Vulgaris: A Promising Adjunctive Treatment”
- 23 November 2025
- Published by Wiley in Oral Surgery
- Vol. 19 (1) , 110-111
The Black Box Dilemma in Oral Pathology: Bridging the Explainability Gap in Artificial Intelligence
- 23 November 2025
- Published by Wiley in Oral Surgery
- Vol. 19 (1) , 110-111
The Black Box Dilemma in Oral Pathology: Bridging the Explainability Gap in Artificial Intelligence
- 4 August 2025
- Published by Wiley in Oral Diseases
- Vol. 32 (1) , 261-262
Comment on: “Could Long COVID Oral Symptoms and COVID ‐19 Vaccination Oral Side Effects be Induced by the Spike Protein?”
- 4 August 2025
- Published by Wiley in Oral Diseases
- Vol. 32 (1) , 261-262
Comment on: “Could Long COVID Oral Symptoms and COVID ‐19 Vaccination Oral Side Effects be Induced by the Spike Protein?”
- Open Access
- 15 July 2025
- Published by Elsevier in Oral Oncology Reports
- Vol. 15
Transforming malignant salivary gland tumor (MSGTs) treatment with AlphaFold: A promising approach
- 15 July 2025
- Published by Elsevier in Oral Oncology Reports
- Vol. 15
Open AccessTransforming malignant salivary gland tumor (MSGTs) treatment with AlphaFold: A promising approach
- 3 June 2025
- Published by Springer Nature in Clinical Oral Investigations
- Vol. 29 (6) , 1-7
Performance of a novel direct-conversion intraoral sensor on the assessment of caries-like lesions – an ex-vivo comparison with conventional (scintillator-dependent) intraoral sensors
Objectives To compare the diagnostic performance of three intraoral complementary metal–oxide–semiconductor (CMOS) sensors, one based on direct conversion (CMOS-DC) and two scintillator-dependent sensors, in assessing noncavitated caries-like lesions. Materials and methods Sixty extracted human caries-free teeth (30 premolars, 30 molars) were selected. A demineralizing solution was used to induce caries-like lesions on the distal surface of 15 premolars (dPM) and the mesial surface of 15 molars (dM), while the remaining teeth were kept sound (sPM, sM). Phantoms were mounted in 4 combinations: dPM-dM, dPM-sM, sPM-dM, and sPM-sM. Standardized radiographs were obtained with one CMOS-DC sensor (XpectVision XVD2530) and two conventional scintillator-dependent CMOS sensors (CMOS-C1: Dexis IXS, and CMOS-C2: Carestream RVG-6200). Three calibrated observers independently assessed the images using a 5-point scale. Observers’ agreement, sensitivity, specificity, accuracy and area under the curve (AUC) were analyzed using Kappa, ANOVA, and Tukey test (p ≤ 0.05). Results Intra- and interobserver agreements ranged from fair to perfect. Specificity (70.57–83.35), accuracy (64.98–71.10), and AUC (72.63–78.00) showed no statistically significant differences (p > 0.05). The CMOS-DC sensor demonstrated significantly higher sensitivity than CMOS-C2 (p = 0.017). Across all sensors, sensitivity was greater for dPM, with higher AUC values for dPM on CMOS-C1 and CMOS-DC sensors. Conclusions The novel CMOS-DC sensor performed comparably to the more commonly used sensors, with slightly superior sensitivity in diagnosing caries-like lesions when those were truly present. Clinical relevance The novel CMOS sensor, based on direct conversion technology, has shown promise in enhancing diagnostic performance and improving clinical outcomes for noncavitated caries lesions.
- 3 June 2025
- Published by Springer Nature in Clinical Oral Investigations
- Vol. 29 (6) , 1-7
Performance of a novel direct-conversion intraoral sensor on the assessment of caries-like lesions – an ex-vivo comparison with conventional (scintillator-dependent) intraoral sensors
Objectives To compare the diagnostic performance of three intraoral complementary metal–oxide–semiconductor (CMOS) sensors, one based on direct conversion (CMOS-DC) and two scintillator-dependent sensors, in assessing noncavitated caries-like lesions. Materials and methods Sixty extracted human caries-free teeth (30 premolars, 30 molars) were selected. A demineralizing solution was used to induce caries-like lesions on the distal surface of 15 premolars (dPM) and the mesial surface of 15 molars (dM), while the remaining teeth were kept sound (sPM, sM). Phantoms were mounted in 4 combinations: dPM-dM, dPM-sM, sPM-dM, and sPM-sM. Standardized radiographs were obtained with one CMOS-DC sensor (XpectVision XVD2530) and two conventional scintillator-dependent CMOS sensors (CMOS-C1: Dexis IXS, and CMOS-C2: Carestream RVG-6200). Three calibrated observers independently assessed the images using a 5-point scale. Observers’ agreement, sensitivity, specificity, accuracy and area under the curve (AUC) were analyzed using Kappa, ANOVA, and Tukey test (p ≤ 0.05). Results Intra- and interobserver agreements ranged from fair to perfect. Specificity (70.57–83.35), accuracy (64.98–71.10), and AUC (72.63–78.00) showed no statistically significant differences (p > 0.05). The CMOS-DC sensor demonstrated significantly higher sensitivity than CMOS-C2 (p = 0.017). Across all sensors, sensitivity was greater for dPM, with higher AUC values for dPM on CMOS-C1 and CMOS-DC sensors. Conclusions The novel CMOS-DC sensor performed comparably to the more commonly used sensors, with slightly superior sensitivity in diagnosing caries-like lesions when those were truly present. Clinical relevance The novel CMOS sensor, based on direct conversion technology, has shown promise in enhancing diagnostic performance and improving clinical outcomes for noncavitated caries lesions.
- 17 January 2025
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
- Vol. 54 (3) , 173-179
Assessment of the quality of root canal fillings—an ex vivo comparison of CBCT scans, conventional intraoral sensors, and a novel photon-counting sensor
Objectives: To compare a novel photon-counting sensor, 2 CBCT protocols and 2 CMOS sensors on the detection of gaps between a gutta-percha cone and root canal walls. Methods: Twenty-five mandibular incisors were prepared to 45/0.04 (size/taper) at working length. Teeth were placed in a partially dentate mandible and single gutta-percha cones of 7 sizes were placed at length, one at a time, for image acquisition with a photon-counting sensor, 2 CBCT protocols (90 µm3, 120 µm3) and 2 CMOS sensors. Three calibrated observers assessed images for gap presence. Sensitivity, specificity, accuracy, AUC, and agreement with gold standard were determined using ANOVA and Tukey test (P ≤ .05). Results: Photon-counting sensor showed superior sensitivity and accuracy (88.47%, 81.57%), significantly higher than the CBCT protocols (50.70%-56.33%, 45.87%-53.17%). Contrarily, the photon-counting sensor showed the lowest specificity (40.27%), significantly lower than the CBCT protocols (90.27%, 97.23%). CMOS sensors showed sensitivity, specificity, and accuracy between 72.23%-74.53%, not differing from other modalities. All intraoral sensors showed AUC around 82.87%-84.03%, significantly higher than CBCT protocol 120 µm3 (74.07%). The file size was inversely related to gap size and percentual agreement with gold standard. Conclusions: CMOS sensors showed consistent results, while the photon-counting sensor had the highest sensitivity but lacked specificity. CBCT protocols excelled in specificity but had lower sensitivity. Advances in knowledge: Novel photon-counting sensors and CBCT imaging provided no significant advantage over conventional sensors in assessing gaps as an indicator of quality of root canal filling. Furthermore, smaller gaps were more difficult to detect, regardless of the imaging technique used.
- 17 January 2025
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
- Vol. 54 (3) , 173-179
Assessment of the quality of root canal fillings—an ex vivo comparison of CBCT scans, conventional intraoral sensors, and a novel photon-counting sensor
Objectives: To compare a novel photon-counting sensor, 2 CBCT protocols and 2 CMOS sensors on the detection of gaps between a gutta-percha cone and root canal walls. Methods: Twenty-five mandibular incisors were prepared to 45/0.04 (size/taper) at working length. Teeth were placed in a partially dentate mandible and single gutta-percha cones of 7 sizes were placed at length, one at a time, for image acquisition with a photon-counting sensor, 2 CBCT protocols (90 µm3, 120 µm3) and 2 CMOS sensors. Three calibrated observers assessed images for gap presence. Sensitivity, specificity, accuracy, AUC, and agreement with gold standard were determined using ANOVA and Tukey test (P ≤ .05). Results: Photon-counting sensor showed superior sensitivity and accuracy (88.47%, 81.57%), significantly higher than the CBCT protocols (50.70%-56.33%, 45.87%-53.17%). Contrarily, the photon-counting sensor showed the lowest specificity (40.27%), significantly lower than the CBCT protocols (90.27%, 97.23%). CMOS sensors showed sensitivity, specificity, and accuracy between 72.23%-74.53%, not differing from other modalities. All intraoral sensors showed AUC around 82.87%-84.03%, significantly higher than CBCT protocol 120 µm3 (74.07%). The file size was inversely related to gap size and percentual agreement with gold standard. Conclusions: CMOS sensors showed consistent results, while the photon-counting sensor had the highest sensitivity but lacked specificity. CBCT protocols excelled in specificity but had lower sensitivity. Advances in knowledge: Novel photon-counting sensors and CBCT imaging provided no significant advantage over conventional sensors in assessing gaps as an indicator of quality of root canal filling. Furthermore, smaller gaps were more difficult to detect, regardless of the imaging technique used.
- 27 July 2024
- Published by Wiley in Clinical Oral Implants Research
- Vol. 35 (11) , 1485-1492
Do the number of zirconia implants and the thickness of CBCT image reconstruction affect the detection of peri‐implant bone defect? A diagnostic accuracy ex vivo study
Objectives: To evaluate the influence of multiplanar reconstruction thickness on the detection of peri‐implant bone defects with a standalone zirconia implant and compare it to when another implant is in the vicinity using cone‐beam computed tomography (CBCT).Materials and Methods: Five dry human mandibles were used to create twenty implant sites in the second premolar and first molar regions. The OP300 Maxio was used to acquire CBCT images (90 kVp, 6.3 mA, 5 × 5 cm FOV, and 0.125 mm3 voxel size) before and after creating 3 mm peri‐implant bone defects in the buccal aspect of the premolar region. Half of the scans featured a single zirconia implant in the premolar region, while the others had two implants in the premolar and molar regions. Three reconstruction thicknesses (0.125 mm, 1 mm, and 2 mm) were considered for the multiplanar reconstruction analyses. Five oral and maxillofacial radiologists assessed the detection of peri‐implant bone defects using a 5‐point scale. Diagnostic parameters were calculated and compared using Two‐way ANOVA (α = .05).Results: The studied factors showed no significant influence on the diagnosis of peri‐implant bone defects (p > .05). Diagnostic performance was notably higher with a single implant, especially with a 2‐mm reconstruction thickness (AUC = 0.88, sensitivity = 0.68, specificity = 0.94). Although the differences were not statistically significant, the results were more modest when two implants were present (AUC = 0.80, sensitivity = 0.58, specificity = 0.82).Conclusions: The presence of an adjacent zirconia implant and variations in reconstruction thickness did not influence the detection of 3 mm buccal peri‐implant bone defects on CBCT images.
- 27 July 2024
- Published by Wiley in Clinical Oral Implants Research
- Vol. 35 (11) , 1485-1492
Do the number of zirconia implants and the thickness of CBCT image reconstruction affect the detection of peri‐implant bone defect? A diagnostic accuracy ex vivo study
Objectives: To evaluate the influence of multiplanar reconstruction thickness on the detection of peri‐implant bone defects with a standalone zirconia implant and compare it to when another implant is in the vicinity using cone‐beam computed tomography (CBCT).Materials and Methods: Five dry human mandibles were used to create twenty implant sites in the second premolar and first molar regions. The OP300 Maxio was used to acquire CBCT images (90 kVp, 6.3 mA, 5 × 5 cm FOV, and 0.125 mm3 voxel size) before and after creating 3 mm peri‐implant bone defects in the buccal aspect of the premolar region. Half of the scans featured a single zirconia implant in the premolar region, while the others had two implants in the premolar and molar regions. Three reconstruction thicknesses (0.125 mm, 1 mm, and 2 mm) were considered for the multiplanar reconstruction analyses. Five oral and maxillofacial radiologists assessed the detection of peri‐implant bone defects using a 5‐point scale. Diagnostic parameters were calculated and compared using Two‐way ANOVA (α = .05).Results: The studied factors showed no significant influence on the diagnosis of peri‐implant bone defects (p > .05). Diagnostic performance was notably higher with a single implant, especially with a 2‐mm reconstruction thickness (AUC = 0.88, sensitivity = 0.68, specificity = 0.94). Although the differences were not statistically significant, the results were more modest when two implants were present (AUC = 0.80, sensitivity = 0.58, specificity = 0.82).Conclusions: The presence of an adjacent zirconia implant and variations in reconstruction thickness did not influence the detection of 3 mm buccal peri‐implant bone defects on CBCT images.
- Open Access
- 1 January 2024
- Published by XMLink in Imaging Science in Dentistry
- Vol. 54 (4) , 327-335
Expression of beam hardening artifacts on horizontally stitched cone-beam computed tomography images
Da Fonte JB, et al. Imaging Sci Dent. 2024 Dec;54(4):327-335. https://doi.org/10.5624/isd.20240061
- 1 January 2024
- Published by XMLink in Imaging Science in Dentistry
- Vol. 54 (4) , 327-335
Open AccessExpression of beam hardening artifacts on horizontally stitched cone-beam computed tomography images
Da Fonte JB, et al. Imaging Sci Dent. 2024 Dec;54(4):327-335. https://doi.org/10.5624/isd.20240061