Do the number of zirconia implants and the thickness of CBCT image reconstruction affect the detection of peri‐implant bone defect? A diagnostic accuracy ex vivo study
Authors:
- Juliana Batista Melo da FonteJFJuliana Batista Melo da Fonte
- Rocharles Cavalcante FonteneleRFRocharles Cavalcante Fontenele
- Amanda Farias‐GomesAFAmanda Farias‐Gomes
- Débora Costa RuizDRDébora Costa Ruiz
- Maria Fernanda Silva Andrade‐BortolettoMAMaria Fernanda Silva Andrade‐Bortoletto
- Saulo L. Sousa MeloSMSaulo L. Sousa Melo
- Deborah Queiroz FreitasDFDeborah Queiroz Freitas
- 27 July 2024
- journal article
- research article
- Published by Wiley in Clinical Oral Implants Research
- Vol. 35 (11) , 1485-1492
Abstract
Objectives: To evaluate the influence of multiplanar reconstruction thickness on the detection of peri‐implant bone defects with a standalone zirconia implant and compare it to when another implant is in the vicinity using cone‐beam computed tomography (CBCT).Materials and Methods: Five dry human mandibles were used to create twenty implant sites in the second premolar and first molar regions. The OP300 Maxio was used to acquire CBCT images (90 kVp, 6.3 mA, 5 × 5 cm FOV, and 0.125 mm3 voxel size) before and after creating 3 mm peri‐implant bone defects in the buccal aspect of the premolar region. Half of the scans featured a single zirconia implant in the premolar region, while the others had two implants in the premolar and molar regions. Three reconstruction thicknesses (0.125 mm, 1 mm, and 2 mm) were considered for the multiplanar reconstruction analyses. Five oral and maxillofacial radiologists assessed the detection of peri‐implant bone defects using a 5‐point scale. Diagnostic parameters were calculated and compared using Two‐way ANOVA (α = .05).Results: The studied factors showed no significant influence on the diagnosis of peri‐implant bone defects (p > .05). Diagnostic performance was notably higher with a single implant, especially with a 2‐mm reconstruction thickness (AUC = 0.88, sensitivity = 0.68, specificity = 0.94). Although the differences were not statistically significant, the results were more modest when two implants were present (AUC = 0.80, sensitivity = 0.58, specificity = 0.82).Conclusions: The presence of an adjacent zirconia implant and variations in reconstruction thickness did not influence the detection of 3 mm buccal peri‐implant bone defects on CBCT images.Keywords
This publication has 33 references indexed in Scilit:
- Influence of an adjacent zirconium implant, tube current, and metal artifact reduction algorithm on horizontal root fracture diagnosis in cone beam computed tomographyOral Surgery, Oral Medicine, Oral Pathology and Oral Radiology, 2023
- Mapping artifacts generated in a tooth adjacent to titanium and zirconia implants located in the endomass and exomass in cone beam computed tomography: an ex vivo studyOral Surgery, Oral Medicine, Oral Pathology and Oral Radiology, 2023
- Influence of Metal Post in Adjacent Teeth in the Detection of Vertical Root Fracture Using Cone-beam Computed Tomography with Different Acquisition ParametersJournal of Endodontics, 2020
- In vitro diagnostic accuracy of low‐dose CBCT for evaluation of peri‐implant bone lesionsClinical Oral Implants Research, 2019
- Cone Beam Computed TomographyDental Clinics of North America, 2018
- Diagnostic performance of cone beam computed tomography in assessing peri‐implant bone loss: A systematic reviewClinical Oral Implants Research, 2018
- Efficacy of a cone beam computed tomography metal artifact reduction algorithm for the detection of peri-implant fenestrations and dehiscencesOral Surgery, Oral Medicine, Oral Pathology and Oral Radiology, 2016
- Detection of periimplant fenestration and dehiscence with the use of two scan modes and the smallest voxel sizes of a cone-beam computed tomography deviceOral Surgery, Oral Medicine, Oral Pathology and Oral Radiology, 2013
- Receiver Operating Characteristic Curve in Diagnostic Test AssessmentJournal of Thoracic Oncology, 2010
- What is Cone-Beam CT and How Does it Work?Dental Clinics of North America, 2008