TWTian Wang

Tian Wang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Tian Wang has a total of 6 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A biomechanical comparison of Kirschner-wire fixation on fracture stability in Salter-Harris type I fractures of the proximal humeral physis in a porcine cadaveric model

    by Jiawen Ma, Tian Wang, Vedran Lovric, Kenneth A. Johnson, William R. Walsh

    The physis is the weakest component of immature long bones, and physeal fractures constitute about 30% of fractures in growing dogs. Fractures of the proximal humeral physis typically have a Salter Harris type I or II configuration. These fractures require accurate reduction and adequate stabilization to allow for any potential continued longitudinal bone growth, in conjunction with physeal fracture healing. Conventional internal fixation of these fractures involves insertion of two parallel Kirschner wires, although other methods described include tension band wiring, Rush pinning, and lag screws. However these recommendations are based on anecdotal evidence, and information about the biomechanical stability of physeal fracture repair is sparse. The unique anatomical structure of the epiphyseal-metaphyseal complex makes the gripping of the epiphysis for ex vivo biomechanical testing of physeal fracture repair very challenging. The objective of our study was to biomechanically assess the optimal number (three, two or one) of implanted Kirschner wires in a porcine Salter Harris I proximal humeral physeal fracture model, using motion analysis tracking of peri-fragmental retro-reflective markers while constructs were subjected to a constant axial compression and a sinusoidal torque of +/− 2 Nm at 0.5 Hz for 250 cycles. There were significant differences between the three constructs (three, two or one Kirschner wire repair) for gross angular displacement (p < 0.001). The difference between three pins and two pins on toggle was not significant (p = 0.053), but both three-pin and two-pin fixation significantly reduced rotational toggle compared to one-pin fixation. Construct stiffness was not significantly different between any of the pin groups (p > 0.33). Motion analysis tracking using peri-fragmental markers in this porcine model of physeal fracture repair found that the stability at the fracture site of one-pin fixation was significantly less than two-pin and three-pin fixation. Whether there was increased stabilization of these fractures with three-pin fixation compared to two-pin fixation was not conclusive in this porcine model.


  • Open Access

    Biomechanical evaluation of a biomimetic spinal construct

    by Tian Wang, Jonathon R Ball, Mattew H Pelletier, William R Walsh

    Laboratory spinal biomechanical tests using human cadaveric or animal spines have limitations in terms of disease transmission, high sample variability, decay and fatigue during extended testing protocols. Therefore, a synthetic biomimetic spine model may be an acceptable substitute. The goal of current study is to evaluate the properties of a synthetic biomimetic spine model; also to assess the mechanical performance of lateral plating following lateral interbody fusion. Three L3/4 synthetic spinal motion segments were examined using a validated pure moment testing system. Moments (±7.5 Nm) were applied in flexion-extension (FE), lateral bending (LB) and axial rotation (AR) at 1Hz for total 10000 cycles in MTS Bionix. An additional test was performed 12 hours after 10000 cycles. A ±10 Nm cycle was also performed to allow provide comparison to the literature. For implantation evaluation, each model was tested in the 4 following conditions: 1) intact, 2) lateral cage alone, 3) lateral cage and plate 4) anterior cage and plate. Results were analysed using ANOVA with post-hoc Tukey’s HSD test. Range of motion (ROM) exhibited logarithmic growth with cycle number (increases of 16%, 37.5% and 24.3% in AR, FE and LB respectively). No signification difference (p > 0.1) was detected between 4 cycles, 10000 cycles and 12 hour rest stages. All measured parameters were comparable to that of reported cadaveric values. The ROM for a lateral cage and plate construct was not significantly different to the anterior lumbar interbody construct for FE (p = 1.00), LB (p = 0.995) and AR (p = 0.837). Based on anatomical and biomechanical similarities, the synthetic spine tested here provides a reasonable model to represent the human lumbar spine. Repeated testing did not dramatically alter biomechanics which may allow non-destructive testing between many different procedures and devices without the worry of carry over effects. Small intra-specimen variability and lack of biohazard makes this an attractive alternative for in vitro spine biomechanical testing. It also proved an acceptable surrogate for biomechanical testing, confirming that a lateral lumbar interbody cage and plate construct reduces ROM to a similar degree as anterior lumbar interbody cage and plate constructs.