PRPatrick Le Roux

Patrick Le Roux

*This is an algorithmically generated author record based on publicly available information.

Patrick Le Roux has a total of 5 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Robust Self-Calibrating nCPMG Acquisition: Application to Body Diffusion-Weighted Imaging

    by Eric K. Gibbons, Patrick Le Roux, Shreyas S. Vasanawala, John M. Pauly, Adam B. Kerr

    This paper demonstrates a robust diffusion-weighted single-shot fast spin echo (SS-FSE) sequence in the presence of significant off-resonance, which includes a variable-density acquisition and a self-calibrated reconstruction as improvements. A non-Carr-Purcell-Meiboom-Gill (nCPMG) SS-FSE acquisition stabilizes both the main and parasitic echo families for each echo. This preserves both the in-phase and quadrature components of the magnetization throughout the echo train. However, nCPMG SS-FSE also promotes aliasing of the quadrature component, which complicates reconstruction. A new acquisition and reconstruction approach is presented here, where the field-of-view is effectively doubled, but a partial k-space and variable density sampling is used to improve scan efficiency. The technique is presented in phantom scans to validate SNR and robustness against rapidly varying object phase. In vivo healthy volunteer examples and the clinical cases are demonstrated in abdominal imaging. This new approach provides comparable SNR to previous nCPMG acquisition techniques as well as providing more uniform apparent diffusion coefficient maps in phantom scans. In vivo scans suggest that this method is more robust against motion than previous approaches. The proposed reconstruction is an improvement to the nCPMG sequence as it is auto-calibrating and is justified to accurately treat the signal model for the nCPMG SS-FSE sequence.


  • Open Access

    Body Diffusion Weighted Imaging Using Non-CPMG Fast Spin Echo

    by Eric K. Gibbons, Patrick Le Roux, Shreyas S. Vasanawala, John M. Pauly, Adam B. Kerr

    SS-FSE is a fast technique that does not suffer from off-resonance distortions to the degree that EPI does. Unlike EPI, SS-FSE is ill-suited to diffusion weighted imaging (DWI) due to the Carr-Purcell-Meiboom-Geill (CPMG) condition. Non-CPMG phase cycling does accommodate SS-FSE and DWI but places constraints on reconstruction, which are resolved here through parallel imaging. Additionally, improved echo stability can be achieved by using short duration and highly selective DIVERSE radiofrequency pulses. Here, signal-to-noise ratio (SNR) comparisons between EPI and nCPMG SS-FSE acquisitions and reconstruction techniques give similar values. Diffusion imaging with nCPMG SS-FSE gives similar SNR to an EPI acquisition, though apparent diffusion coefficient values are higher than seen with EPI. In vivo images have good image quality with little distortion. This method has the ability to capture distortion-free DWI images near areas of significant off-resonance as well as preserve adequate SNR. Parallel imaging and DIVERSE refocusing RF pulses allow shorter ETL compared to previous implementations and thus reduces phase encode direction blur and SAR accumulation.