  • Open Access

    Optimization of Bloch-Siegert B1 Mapping Sequence for Maximum Signal to Noise

    by M. Mehdi Khalighi, Doug Kelley, Jason H. Su, Brian K. Rutt, Adam B. Kerr

    Adiabatic Bloch-Siegert B1+ mapping method addresses the long TE and high RF power deposition problems of conventional Bloch-Siegert B1+ mapping by introducing short frequency-swept ABS pulses with maximum sensitivity. Here, it is shown how maximum signal to noise ratio can be achieved in adiabatic Bloch-Siegert B1+ mapping. Signal to noise ratio of B1+ maps is maximized by optimizing the adiabatic pulse parameters such as width, amplitude and shape of the Bloch-Siegert pulse within a specified scan time and under approved SAR guidelines. Equations for optimized Bloch-Siegert pulse parameters are derived, which are dependent on the base pulse sequence used for B1+ mapping as well as tissue properties and transmit coil configuration. It is shown that by this optimization it is more efficient to increase TR rather than using the averaging method to increase signal to noise ratio.

  • Open Access

    Robust Self-Calibrating nCPMG Acquisition: Application to Body Diffusion-Weighted Imaging

    by Eric K. Gibbons, Patrick Le Roux, Shreyas S. Vasanawala, John M. Pauly, Adam B. Kerr

    This paper demonstrates a robust diffusion-weighted single-shot fast spin echo (SS-FSE) sequence in the presence of significant off-resonance, which includes a variable-density acquisition and a self-calibrated reconstruction as improvements. A non-Carr-Purcell-Meiboom-Gill (nCPMG) SS-FSE acquisition stabilizes both the main and parasitic echo families for each echo. This preserves both the in-phase and quadrature components of the magnetization throughout the echo train. However, nCPMG SS-FSE also promotes aliasing of the quadrature component, which complicates reconstruction. A new acquisition and reconstruction approach is presented here, where the field-of-view is effectively doubled, but a partial k-space and variable density sampling is used to improve scan efficiency. The technique is presented in phantom scans to validate SNR and robustness against rapidly varying object phase. In vivo healthy volunteer examples and the clinical cases are demonstrated in abdominal imaging. This new approach provides comparable SNR to previous nCPMG acquisition techniques as well as providing more uniform apparent diffusion coefficient maps in phantom scans. In vivo scans suggest that this method is more robust against motion than previous approaches. The proposed reconstruction is an improvement to the nCPMG sequence as it is auto-calibrating and is justified to accurately treat the signal model for the nCPMG SS-FSE sequence.


  • Open Access

    Body Diffusion Weighted Imaging Using Non-CPMG Fast Spin Echo

    by Eric K. Gibbons, Patrick Le Roux, Shreyas S. Vasanawala, John M. Pauly, Adam B. Kerr

    SS-FSE is a fast technique that does not suffer from off-resonance distortions to the degree that EPI does. Unlike EPI, SS-FSE is ill-suited to diffusion weighted imaging (DWI) due to the Carr-Purcell-Meiboom-Geill (CPMG) condition. Non-CPMG phase cycling does accommodate SS-FSE and DWI but places constraints on reconstruction, which are resolved here through parallel imaging. Additionally, improved echo stability can be achieved by using short duration and highly selective DIVERSE radiofrequency pulses. Here, signal-to-noise ratio (SNR) comparisons between EPI and nCPMG SS-FSE acquisitions and reconstruction techniques give similar values. Diffusion imaging with nCPMG SS-FSE gives similar SNR to an EPI acquisition, though apparent diffusion coefficient values are higher than seen with EPI. In vivo images have good image quality with little distortion. This method has the ability to capture distortion-free DWI images near areas of significant off-resonance as well as preserve adequate SNR. Parallel imaging and DIVERSE refocusing RF pulses allow shorter ETL compared to previous implementations and thus reduces phase encode direction blur and SAR accumulation.


  • Hybrid-Space SENSE Reconstruction for Simultaneous Multi-Slice MRI

    by Kangrong Zhu, Robert F. Dougherty, Hua Wu, Matthew J. Middione, Atsushi M. Takahashi, Tao Zhang, John M. Pauly, Adam B. Kerr

    Simultaneous Multi-Slice (SMS) magnetic resonance imaging (MRI) is a rapidly evolving technique for increasing imaging speed. Controlled aliasing techniques utilize periodic undersampling patterns to help mitigate the loss in signal-to-noise ratio (SNR) in SMS MRI. To evaluate the performance of different undersampling patterns, a quantitative description of the image SNR loss is needed. Additionally, eddy current effects in echo planar imaging (EPI) lead to slice-specific Nyquist ghosting artifacts. These artifacts cannot be accurately corrected for each individual slice before or after slice-unaliasing. In this work, we propose a hybrid-space sensitivity encoding (SENSE) reconstruction framework for SMS MRI by adopting a three-dimensional representation of the SMS acquisition. Analytical SNR loss maps are derived for SMS acquisitions with arbitrary phase encoding undersampling patterns. Moreover, we propose a matrix-decoding correction method that corrects the slice-specific Nyquist ghosting artifacts in SMS EPI acquisitions. Brain images demonstrate that the proposed hybrid-space SENSE reconstruction generates images with comparable quality to commonly used split-slice-generalized autocalibrating partially parallel acquisition reconstruction. The analytical SNR loss maps agree with those calculated by a Monte Carlo based method, but require less computation time for high quality maps. The analytical maps enable a fair comparison between the performances of coherent and incoherent SMS undersampling patterns. Phantom and brain SMS EPI images show that the matrix-decoding method performs better than the single-slice and slice-averaged Nyquist ghosting correction methods under the hybrid-space SENSE reconstruction framework.


  • RF Field Visualization of RF Ablation at the Larmor Frequency

    by Kim Shultz, Pascal Stang, Adam Kerr, John Pauly, Greig Scott

    Radio-frequency ablation (RFA) is an effective minimally invasive treatment for tumors. One primary source of difficulty is monitoring and controlling the ablation region. Currently, RFA is performed at 460 kHz, for which magnetic resonance imaging (MRI) could play a role given its capability for temperature monitoring and tumor visualization. If instead the ablation were to be performed at the MRI Larmor frequency, then the MR capability for B1 field mapping could be used to directly visualize the radio-frequency (RF) fields created by the ablation currents. Visualizing the RF fields may enable better control of the ablation currents, enabling better control of lesion shape and size and improving repeatability. We demonstrate the feasibility of performing RFAs at 64 MHz and show preliminary results from imaging the RF fields from the ablation. The post-ablation RF fields show an increase in current density in the ablated region, consistent with an increase in conductivity of the ablated tissue.


  • Frequency-Offset Cartesian Feedback for MRI Power Amplifier Linearization

    by Marta G. Zanchi, Pascal Stang, Adam Kerr, John M. Pauly, Greig C. Scott

    High-quality magnetic resonance imaging (MRI) requires precise control of the transmit radio-frequency (RF) field. In parallel excitation applications such as transmit SENSE, high RF power linearity is essential to cancel aliased excitations. In widely-employed class AB power amplifiers, gain compression, cross-over distortion, memory effects, and thermal drift all distort the RF field modulation and can degrade image quality. Cartesian feedback (CF) linearization can mitigate these effects in MRI, if the quadrature mismatch and dc offset imperfections inherent in the architecture can be minimized. In this paper, we present a modified Cartesian feedback technique called “frequency-offset Cartesian feedback” (FOCF) that significantly reduces these problems. In the FOCF architecture, the feedback control is performed at a low intermediate frequency rather than dc, so that quadrature ghosts and dc errors are shifted outside the control bandwidth. FOCF linearization is demonstrated with a variety of typical MRI pulses. Simulation of the magnetization obtained with the Bloch equation demonstrates that high-fidelity RF reproduction can be obtained even with inexpensive class AB amplifiers. Finally, the enhanced RF fidelity of FOCF over CF is demonstrated with actual images obtained in a 1.5 T MRI system.