Xue Sun
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Xue Sun has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Ying Zhang
Department of Ultrasound, Shengjing Hospital of China Medical University, Shenyang, China
3 shared publications - Yu Wang
Department of Ultrasound, Shengjing Hospital of China Medical University, Shenyang, China
3 shared publications - Meilian Wang
Department of Microbiology and Parasitology, College of Basic Medical Sciences, China Medical University, Shenyang, China
2 shared publications - Miao Fan
Department of Radiology, The first Affiliated Hospital of Sun Yat-sen University, Guangzhou, China...
2 shared publications - Wei Sun
Department of Sonography, Shengjing Hospital of China Medical University,Shenyang, China...
2 shared publications - Wenjia Lei
Department of Sonography, Shengjing Hospital of China Medical University, Shenyang, China
2 shared publications
Latest Publications
- Open Access
- 28 January 2021
- Published by Springer Nature in Cardiovascular Ultrasound
- Vol. 19 (1) , 1-10
Prenatal evaluation of fetal atrioventricular valves by real-time 4D volume imaging with electronic matrix probe
Background: The purpose of this study is to evaluate the feasibility using real-time four-dimensional (RT 4D) volume imaging with electronic matrix probe to observe the morphology of atrioventricular valves in normal and abnormal fetuses, measure the area and circumference of atrioventricular valves in normal fetuses and analyze the correlation with gestational age. Methods: RT 4D volume imaging with electronic matrix probe was used to collect cardiac volume data of 162 normal fetuses with the gestational age from 22 to 32 weeks and 19 fetuses with atrioventricular valves abnormalities were also enrolled. All the volume data were analyzed and processed in real-time. The morphology of mitral and tricuspid valves was observed in surface mode. The area and circumference of valves were measured in a 4D render view at the end of diastole and analyzed the correlation with gestational age. Results: In 148 of 162 fetuses (91%), the 4D rendered image could be successfully obtained, which clearly showed the morphology of the atrioventricular valves. The area and circumference of mitral and tricuspid valves were positively correlated with gestational age (P < 0.01). Furthermore, 4D rendered images were successfully obtained in 17 of 19 fetuses (89%) with atrioventricular valves abnormalities. Conclusions: The reference range of the area and circumference of atrioventricular valves in normal fetuses at different gestational weeks could be determined by using the RT 4D volume imaging with electronic matrix probe, which can provide certain diagnostic information for the clinic. The RT 4D images could display the valves morphology vividly in both normal and abnormal fetuses, including some subtle lesions which are not identified by traditional two-dimensional (2D) echocardiography. It is feasible to use the RT 4D volume imaging with electronic matrix probe to perform the prenatal evaluation in the fetal atrioventricular valves.
- 28 January 2021
- Published by Springer Nature in Cardiovascular Ultrasound
- Vol. 19 (1) , 1-10
Open AccessPrenatal evaluation of fetal atrioventricular valves by real-time 4D volume imaging with electronic matrix probe
Background: The purpose of this study is to evaluate the feasibility using real-time four-dimensional (RT 4D) volume imaging with electronic matrix probe to observe the morphology of atrioventricular valves in normal and abnormal fetuses, measure the area and circumference of atrioventricular valves in normal fetuses and analyze the correlation with gestational age. Methods: RT 4D volume imaging with electronic matrix probe was used to collect cardiac volume data of 162 normal fetuses with the gestational age from 22 to 32 weeks and 19 fetuses with atrioventricular valves abnormalities were also enrolled. All the volume data were analyzed and processed in real-time. The morphology of mitral and tricuspid valves was observed in surface mode. The area and circumference of valves were measured in a 4D render view at the end of diastole and analyzed the correlation with gestational age. Results: In 148 of 162 fetuses (91%), the 4D rendered image could be successfully obtained, which clearly showed the morphology of the atrioventricular valves. The area and circumference of mitral and tricuspid valves were positively correlated with gestational age (P < 0.01). Furthermore, 4D rendered images were successfully obtained in 17 of 19 fetuses (89%) with atrioventricular valves abnormalities. Conclusions: The reference range of the area and circumference of atrioventricular valves in normal fetuses at different gestational weeks could be determined by using the RT 4D volume imaging with electronic matrix probe, which can provide certain diagnostic information for the clinic. The RT 4D images could display the valves morphology vividly in both normal and abnormal fetuses, including some subtle lesions which are not identified by traditional two-dimensional (2D) echocardiography. It is feasible to use the RT 4D volume imaging with electronic matrix probe to perform the prenatal evaluation in the fetal atrioventricular valves.
- 6 December 2017
- Published by SRUMB - Romanian Society for Ultrasonography in Medicine and Biology in Medical Ultrasonography
- Vol. 20 (2) , 213-220
Right heart dilatation in a fetus with an abnormal foramen ovale valve: an indicator of interatrial communication restriction
Aims: Foramen ovale (FO) valve with a shape or motion abnormality is frequently detected during routine obstetric ultrasonic examinations. However, the hemodynamics mechanism of this entity remains unclear. The purpose of the study is to determine the relevance of interatrial communication restriction and resultant morphological modifications.Materials and methods: We reviewed the echocardiographic records of fetuses with isolated abnormal FO valve evaluated between January of 2010 and december of 2016. The size (DFO) of the FO orifice, opening angle (α) of the FO valve, and dimensions of cardiac chambers, FO channel outlet (DOUT) and inferior vena cava (DIVC) were measured. We evaluated their (DFO, DOUT, α) relationships to the diameters of RA and DIVC. Five hundred and seventy normal fetuses were selected to establish the normal range of the DOUT/DIVC ratio so as to provide a criterion for restriction.Results: An abnormal FO valve was identified in 89 fetuses without congenital heart disease, with restriction noted in 62 fetuses (45 fetuses with RA dilatation, 12 fetuses with RA and RV dilatation, and 5 fetuses with no RA dilatation). There were no significant correlations between RA/LA and DFO/DIVC, RA/ LA and α. RA/LA was negatively correlated with DOUT/DIVC (R2=0.97, p<0.01).Conclusions: For a fetus with an abnormal FO valve, right heart dilatation could be considered as an indicator of interatrial communication restriction, which could be assessed by evaluating the FO channel outlet. The degree of right atrium dilatation indicates the severity of the restriction.
- 6 December 2017
- Published by SRUMB - Romanian Society for Ultrasonography in Medicine and Biology in Medical Ultrasonography
- Vol. 20 (2) , 213-220
Right heart dilatation in a fetus with an abnormal foramen ovale valve: an indicator of interatrial communication restriction
Aims: Foramen ovale (FO) valve with a shape or motion abnormality is frequently detected during routine obstetric ultrasonic examinations. However, the hemodynamics mechanism of this entity remains unclear. The purpose of the study is to determine the relevance of interatrial communication restriction and resultant morphological modifications.Materials and methods: We reviewed the echocardiographic records of fetuses with isolated abnormal FO valve evaluated between January of 2010 and december of 2016. The size (DFO) of the FO orifice, opening angle (α) of the FO valve, and dimensions of cardiac chambers, FO channel outlet (DOUT) and inferior vena cava (DIVC) were measured. We evaluated their (DFO, DOUT, α) relationships to the diameters of RA and DIVC. Five hundred and seventy normal fetuses were selected to establish the normal range of the DOUT/DIVC ratio so as to provide a criterion for restriction.Results: An abnormal FO valve was identified in 89 fetuses without congenital heart disease, with restriction noted in 62 fetuses (45 fetuses with RA dilatation, 12 fetuses with RA and RV dilatation, and 5 fetuses with no RA dilatation). There were no significant correlations between RA/LA and DFO/DIVC, RA/ LA and α. RA/LA was negatively correlated with DOUT/DIVC (R2=0.97, p<0.01).Conclusions: For a fetus with an abnormal FO valve, right heart dilatation could be considered as an indicator of interatrial communication restriction, which could be assessed by evaluating the FO channel outlet. The degree of right atrium dilatation indicates the severity of the restriction.
- Open Access
- 23 June 2017
- Published by Springer Nature in Cardiovascular Ultrasound
- Vol. 15 (1) , 17
Prenatal screening of fetal ventriculoarterial connections: benefits of 4D technique in fetal heart imaging
Identification of prenatal ventriculoarterial connections in fetuses with conotruncal anomalies (CTA) remains one of the greatest challenges for sonographers performing screening examinations. Herein, we propose a novel protocol of 4D volume analysis that identifies ventriculoarterial connections and evaluate its clinical utility in routine screenings. Twenty-nine cases of transposition of the great arteries (TGA), 22 cases of double-outlet right ventricle (DORV), 36 cases of tetralogy of Fallot (TOF), 14 cases of truncus arteriosus (TCA), and randomly selected 70 normal fetuses were reviewed in this study. All cases were evaluated using 2D data alone (2D method), post-processing volumes with no exact algorithm (4D-1 method), or with the proposed algorithm (4D-2 method), or using the 2D and 4D data together (combined method). Comparisons were made to evaluate the detection rate of ventriculoarterial connections for these different methods. During 18–28 gestational weeks, the detection rate of 4D-2 modality was satisfactory. The detection rate of the combined method was significantly higher than 2D method in the identification of TGA, TOF, and TCA. The detection rate of 4D-1 method was significantly lower than 4D −2 modality for CTA fetuses. During late pregnancy, the detection rate for both 4D modalities was very low due to the poor quality of the 4D volumes. We proposed a detailed protocol, which allowed the examiner to identify fetal ventriculoarterial connections by 4D volumes. Inclusion of blood information into the volumes improved diagnosis. Our findings suggest that the incorporation of 4D STIC into routine screenings could improve the detection for TGA, TOF, and TCA.
- 23 June 2017
- Published by Springer Nature in Cardiovascular Ultrasound
- Vol. 15 (1) , 17
Open AccessPrenatal screening of fetal ventriculoarterial connections: benefits of 4D technique in fetal heart imaging
Identification of prenatal ventriculoarterial connections in fetuses with conotruncal anomalies (CTA) remains one of the greatest challenges for sonographers performing screening examinations. Herein, we propose a novel protocol of 4D volume analysis that identifies ventriculoarterial connections and evaluate its clinical utility in routine screenings. Twenty-nine cases of transposition of the great arteries (TGA), 22 cases of double-outlet right ventricle (DORV), 36 cases of tetralogy of Fallot (TOF), 14 cases of truncus arteriosus (TCA), and randomly selected 70 normal fetuses were reviewed in this study. All cases were evaluated using 2D data alone (2D method), post-processing volumes with no exact algorithm (4D-1 method), or with the proposed algorithm (4D-2 method), or using the 2D and 4D data together (combined method). Comparisons were made to evaluate the detection rate of ventriculoarterial connections for these different methods. During 18–28 gestational weeks, the detection rate of 4D-2 modality was satisfactory. The detection rate of the combined method was significantly higher than 2D method in the identification of TGA, TOF, and TCA. The detection rate of 4D-1 method was significantly lower than 4D −2 modality for CTA fetuses. During late pregnancy, the detection rate for both 4D modalities was very low due to the poor quality of the 4D volumes. We proposed a detailed protocol, which allowed the examiner to identify fetal ventriculoarterial connections by 4D volumes. Inclusion of blood information into the volumes improved diagnosis. Our findings suggest that the incorporation of 4D STIC into routine screenings could improve the detection for TGA, TOF, and TCA.