YWYu Wang

Yu Wang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Yu Wang has a total of 55 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    CHDPIR: a piRNA with biomarker and therapeutic potential in congenital heart disease

    by Xue Sun, Gebang Wang, Hui Gu, Nan Zhang, Wenxin Yang, Wenting Luo, Yu Wang, Zhengwei Yuan

  • Automated Prediction of Subsequent Miscarriage Risk in Pregnant Women by Early First-trimester Ultrasound Characteristics Based on the Convolutional Neural Network Model

    by Yu Wang, Fangfang Han, Chuanjie Lei, Qixin Zhang, Chenghuan Yin, Yueyang Teng, Zhengwei Yuan

    Predicting the risk of subsequent miscarriage during the first trimester is crucial for optimizing ultrasound surveillance and alleviating psychological distress for pregnant women. This study aims to develop a multi-input convolutional neural network (CNN) that integrates early gestational ultrasound images with clinical measurements to assess miscarriage risk, while providing interpretable visual explanations to support clinical decision-making. Utilizing a retrospective dataset of singleton pregnancies at 6–8 weeks of gestation, we extracted gestational sac regions through three distinct segmentation strategies and trained a CNN-based classifier to differentiate between normal and miscarriage outcomes. The predictive performance was evaluated using accuracy, precision, recall, f1-score, and the area under the receiver operating characteristic curve (AUC). The results indicated that the multi-input CNN outperformed single-input models. Additionally, an edge-expanded segmentation strategy demonstrated superior performance compared to both precise segmentation and rectangular cropping. By incorporating Gradient-weighted Class Activation Mapping (Grad-CAM) and SHapley Additive exPlanations (SHAP), we identified subchorionic regions as significant biomarkers and clarified the differences in attention to features among different models, thereby enhancing the interpretability and clinical applicability of the model for early pregnancy risk assessment.

  • Open Access

    Prenatal Diagnosis of Pulmonary Atresia With Ventricular Septal Defect and an Aberrant Ductus Arteriosus in a Dextrocardia by Two- and Three-Dimensional Echocardiography: A Case Report

    by Lulu Liang, Yu Wang, Ying Zhang

    Introduction: Prenatal diagnosis of pulmonary atresia is difficult in relative, especially when the pulmonary artery is slim and hypoplastic in development. It is of great importance to search for the blood supply to the pulmonary artery in those fetuses while it challenges most screening sonographers, even fetal echocardiography specialists. We herein report a rare case of pulmonary atresia with ventricular septal defect, complicated with an aberrant ductus arteriosus which provides the blood supply to the pulmonary artery. Besides, the case was also accompanied by cardiac malposition, dextrocardia with situs solitus. The echocardiographic characteristics and autopsy findings are also presented to approach the skill of fetal diagnosis.Case presentation: A 30-year-old primigravida woman was referred to our center at gestational age of (24 ± 3) weeks for further fetal cardiac examination for suspected fetal cardiac anomalies. Fetal echocardiography revealed dextrocardia, situs solitus of the atria, an L-ventricular loop, a ventricular septal defect, an enlarged coronary sinus, and pulmonary atresia by transverse scanning. The ductus arteriosus was not present at the three-vessel trachea view with the retrograde flow showing in the pulmonary artery trunk, which suggested the possibility of an aberrant ductus arteriosus. Sagittal and coronal scanning was attempted to find that the pulmonary artery connected with the innominate artery via the aberrant ductus arteriosus. Three-dimensional echocardiography with spatio-temporal image correlation and high-definition flow imaging technique was performed to obtain the three-dimensional rendered image, which clearly showed the malformation in space. The pregnancy was terminated and the gross findings confirmed the prenatal diagnosis.Conclusion: A detailed evaluation of fetal cardiac anatomy and hemodynamics is crucial for the detection of an aberrant ductus arteriosus, which plays an important role in the diagnosis of pulmonary atresia with ventricular septal defect. Sagittal and coronal scanning is useful to find the course of this aberrant ductus arteriosus. The three-dimensional echocardiography with spatio-temporal image correlation technique could provide additional spatial information to show great arteries in detail, which can serve as a supplement to traditional two-dimensional modality and benefit examiners to make an accurate diagnosis.


  • Maternal exposure to heavy metals and risk for severe congenital heart defects in offspring

    by Chengrong Wang, Xin Pi, Shengju Yin, Mengyuan Liu, Tian Tian, Lei Jin, Jufen Liu, Zhiwen Li, Linlin Wang, Zhengwei Yuan, et al.


  • Open Access

    Effect of Four-in-One Optimized Emergency Nursing Procedure on Symptoms and Vital Signs of Patients with Mushroom Poisoning

    by Suling Li, Kunyu Liu, Zhenning Liu, Yu Wang

    Most members of the general public find it difficult to identify poisonous wild mushrooms, resulting in family food poisoning. Toxic mushroom poisoning can produce nausea, vomiting, abdominal pain, and other severe symptoms 30 minutes or more after ingestion that can even lead to death. Using a “four-in-one” optimized emergency nursing procedure to treat mushroom poisoning can reduce the rescue time and improve the survival rate of patients. This study aimed to analyze the influence of a “four-in-one” optimized emergency nursing procedure to treat patients with toadstool poisoning. A prospective randomized study was conducted. Sixteen cases of toadstool poisoning, corresponding to 78 patients admitted to our hospital from January 2017 to July 2020, were selected and divided into a study group and a control group of 39 cases each using a random number table. The control group was provided with routine emergency care, and the study group was given a “four-in-one” treatment that optimized the emergency care process; both groups were subjected to basic treatment + blood purification and other treatment measures, and the treatment time in the rescue room and the first blood purification time of the two groups were compared. Differences in routine blood tests, liver and kidney function indices, hospitalization time, coma time, treatment outcome, and nursing satisfaction before and after treatment were found. The treatment time and the first blood purification time of the study group were lower than those of the control group, and the difference was statistically significant ( ); ALT, AST, TBIL, TBA, and ALB were measured upon admission for the study and the control groups. The measured values of PT, APTT, CK, CK-MB, and BUN were compared for the two groups, but the difference in the values between the two groups was not statistically significant ( ); after 7 days of treatment, the ALT, TBA, and APTT indicators of the study group were lower than those of the control group, and the difference was statistically significant ( ); the measured values of ALT, AST, TBIL, TBA, ALB, PT, APTT, CK, CK-MB, BUN, and Scr after 7 days of treatment were significantly lower than those before treatment for both groups ( ). The length of stay for the study group was lower than that for the control group, and the difference was statistically significant ( ); the treatment efficiency was 87.18% for the study group, compared with 82.05% for the control group, but the difference was not statistically significant ( ). The study group rated nursing care as follows: very satisfactory, 79.49%; relatively satisfactory, 15.38%; and acceptable, 5.13%; the control group rated nursing care as follows: very satisfactory, 51.28%; relatively satisfactory, 30.77%; and acceptable, 12.82%; the results were statistically significant ( ). Using a “four-in-one” optimized emergency care process to treat patients with mushroom poisoning can significantly reduce the rescue room treatment time and the first blood purification time and improve nursing satisfaction, but has a limited effect on improving the treatment efficiency.


  • Open Access

    Evaluation of prenatal changes in fetal cardiac morphology and function in maternal diabetes mellitus using a novel fetal speckle-tracking analysis: a prospective cohort study

    by Dong Wang, Caixia Liu, Xinyu Liu, Ying Zhang, Yu Wang

    Background: Due to metabolic changes in the second trimester and the increasing number of pregnant women with obesity and advanced maternal age, the incidence of gestational diabetes mellitus (GDM) remains high. This study aimed to evaluate the effects of GDM on fetal cardiac morphology and function, and to determine whether these changes increase with increasing estimated fetal weight (EFW). Methods: Fifty-eight women with GDM (GDM group) and 58 women with a healthy pregnancy (control group) were included in this prospective observational cohort study. Each group included subgroups of 31 pregnant women with a gestational age between 24+0 weeks and 27+6 weeks as well as 27 pregnant women with a gestational age between 28+0 weeks and 40+0 weeks. For all fetuses, a cine of 2–3 s in the four-chamber view was obtained, and online speckle-tracking analysis was performed using the GE Automatic Fetal Heart Assessment Tool (fetal HQ; General Electric Healthcare Ultrasound, Zipf, Austria) to measure the global sphericity index (GSI), global longitudinal strain (GLS), fractional area change (FAC), 24-segment sphericity index (SI), and 24-segment end-diastolic diameter of the left ventricle (LV) and right ventricle (RV). Data were analyzed using the independent t-test and Wilcoxon rank-sum test, as applicable. Results: The GDM group (mean HbA1c value was 5.3 ± 0.57 mmol/L) showed a lower GSI value than the control group (1.21 vs. 1.27, P = 0.000), which indicated a rounder shape of the heart. In addition, fetuses in the GDM group demonstrated significant impairment in cardiac function compared to those in the control group (LV-GLS: -18.26% vs. -22.70%, RV-GLS: -18.52% vs. -22.74%, LV-FAC: 35.30% vs. 42.36%, RV-FAC: 30.89% vs. 36.80%; P = 0.000 for all). Subgroup analyses according to gestational age (24+0–27+6 weeks and 28+0–40+0 weeks) showed that the statistical differences were retained between the GDM and control groups in each subgroup. Conclusions: Fetuses of women with GDM present with signs of biventricular systolic dysfunction according to deformation analysis using fetal HQ. Additionally, the heart had a rounder shape in the GDM group than in the control group. This study showed that fetal HQ can be used to assess fetal cardiac morphology and function easily and quickly, and the effects of GDM on fetal cardiac morphology and function appeared from the second trimester. Thus, whether earlier and stricter clinical intervention was necessary remained to be further studied. Furthermore, future studies will need to supplement the effects of blood glucose levels on GLS, FAC, GSI, and 24-segment SI. Additionally, the long-term follow-up after birth should also be improved to observe the influence of changes in the indicators on the prognosis.


  • Open Access

    Prenatal diagnosis of an aberrant ductus venosus draining into the coronary sinus using two- and three-dimensional echocardiography: a case report

    by Yu Wang, Ying Zhang, Meilian Wang

    Background: Ductus venosus (DV) abnormalities may be associated with intracardiac or extracardiac deformities, chromosomal anomalies, and/or congestive heart failure. Aberrant DV connecting with the coronary sinus (CS) is rare and the prenatal diagnosis presents challenges for most examiners.Case presentation: A 35-year-old pregnant woman, gravida 2, para 1, was referred to our center at 27 gestational weeks for a full evaluation of fetal cardiac anomalies. Transverse scans indicated normal cardiac anatomy except for a dilated CS; we then scanned sagittal planes to clarify the reasons for the CS dilatation. High-definition flow imaging (HDFI) together with radiant flow (R-flow) imaging was used to delineate the aberrant DV returning to the CS, enabling the diagnosis. Three-dimensional (3D) technology was also used to obtain color-rendered images showing the spatial relationships of the vessels involved, thus confirming the two-dimensional (2D) diagnosis. Chromosomal analysis revealed a normal karyotype. The neonate appeared healthy and the echocardiogram showed a normal cardiac anatomy except for a dilated CS with the DV closed and imperceptible.Conclusions: The aberrant course of the DV returning to the CS was clearly demonstrable by traditional 2D echocardiography using HDFI and the R-flow technique. We deem it helpful to trace the inflow of the dilated CS to make the differential diagnosis. The 3D modality might also provide additional spatial information on the associated vessels and thereby assist in prenatal diagnosis.


  • Open Access

    Prenatal evaluation of fetal atrioventricular valves by real-time 4D volume imaging with electronic matrix probe

    by Huiyu Tang, Wei Sun, Xue Sun, Yu Wang, Yu Qi, Dong Wang, Ying Zhang

    Background: The purpose of this study is to evaluate the feasibility using real-time four-dimensional (RT 4D) volume imaging with electronic matrix probe to observe the morphology of atrioventricular valves in normal and abnormal fetuses, measure the area and circumference of atrioventricular valves in normal fetuses and analyze the correlation with gestational age. Methods: RT 4D volume imaging with electronic matrix probe was used to collect cardiac volume data of 162 normal fetuses with the gestational age from 22 to 32 weeks and 19 fetuses with atrioventricular valves abnormalities were also enrolled. All the volume data were analyzed and processed in real-time. The morphology of mitral and tricuspid valves was observed in surface mode. The area and circumference of valves were measured in a 4D render view at the end of diastole and analyzed the correlation with gestational age. Results: In 148 of 162 fetuses (91%), the 4D rendered image could be successfully obtained, which clearly showed the morphology of the atrioventricular valves. The area and circumference of mitral and tricuspid valves were positively correlated with gestational age (P < 0.01). Furthermore, 4D rendered images were successfully obtained in 17 of 19 fetuses (89%) with atrioventricular valves abnormalities. Conclusions: The reference range of the area and circumference of atrioventricular valves in normal fetuses at different gestational weeks could be determined by using the RT 4D volume imaging with electronic matrix probe, which can provide certain diagnostic information for the clinic. The RT 4D images could display the valves morphology vividly in both normal and abnormal fetuses, including some subtle lesions which are not identified by traditional two-dimensional (2D) echocardiography. It is feasible to use the RT 4D volume imaging with electronic matrix probe to perform the prenatal evaluation in the fetal atrioventricular valves.