Victor Danzinger
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Victor Danzinger has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Christina Leydolt
From the Department of Ophthalmology and Optometry, Medical University of Vienna, Vienna, Austria
9 shared publications - Claudette Abela-Formanek
From the Department of Ophthalmology and Optometry, Medical University of Vienna, Vienna, Austria
9 shared publications - Daniel Schartmüller
From the Department of Ophthalmology and Optometry, Medical University of Vienna, Vienna, Austria
9 shared publications - Marcus Lisy
From the Department of Ophthalmology and Optometry, Medical University of Vienna, Vienna, Austria
8 shared publications - Markus Schranz
From the Department of Ophthalmology and Optometry, Medical University of Vienna, Vienna, Austria
8 shared publications - Nikolaus Mahnert
From the Department of Ophthalmology and Optometry, Medical University of Vienna, Vienna, Austria
5 shared publications
Latest Publications
- Open Access
- 9 September 2026
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
Prospective evaluation of visual performance of a novel partial–depth-of-field intraocular lens using a monovision strategy
Purpose: To assess visual and patient-reported outcomes of a partial–depth-of-field (DOFi) intraocular lens (IOL) using a monovision strategy. Setting: Department of Ophthalmology and Optometry, Medical University of Vienna, Vienna, Austria. Design: Single-center, prospective, clinical trial. Methods: 49 patients underwent bilateral cataract surgery, implantation of the partial-DOFi Vivinex Impress XY1-EM IOL, and returned for final follow-up. Follow-up occurred between 30 and 90 days postoperatively, at which manifest refractive spherical equivalent (MRSE), binocular uncorrected visual acuities, defocus curve, corneal wavefront aberrometry, pupil size, IOL tilt and decentration, near stereopsis, photic phenomena, and the Visual Functioning-7 questionnaire were evaluated. Results: Postoperative MRSE was −0.14 ± 0.26 diopters (D) and −0.84 ± 0.44 D in dominant and nondominant eyes, respectively. Binocular uncorrected distance visual acuity and uncorrected intermediate visual acuity (at both 80 cm and 66 cm) reached 0.05 logMAR or better, with a mean uncorrected near visual acuity of 0.20 ± 0.11 logMAR. The defocus curve confirmed a broad visual function (≤0.2 logMAR) across a range from +0.50 D to −2.22 D. Intermediate vision was significantly influenced by photopic pupil diameter and corneal spherical aberration ( P < .05). Low levels of IOL tilt, decentration, and corneal higher-order aberrations were observed. Patients reported high visual function (VF-7) and normal stereopsis, without disturbing photic phenomena. Conclusions: Using a new partial-DOFi IOL in a monovision protocol yielded excellent distance to intermediate vision and functional near visual acuity. These results, supported by high subjective visual function and the lack of bothersome photic phenomena, suggest the potential of this strategy for extending the range of vision.
- 9 September 2026
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
Open AccessProspective evaluation of visual performance of a novel partial–depth-of-field intraocular lens using a monovision strategy
Purpose: To assess visual and patient-reported outcomes of a partial–depth-of-field (DOFi) intraocular lens (IOL) using a monovision strategy. Setting: Department of Ophthalmology and Optometry, Medical University of Vienna, Vienna, Austria. Design: Single-center, prospective, clinical trial. Methods: 49 patients underwent bilateral cataract surgery, implantation of the partial-DOFi Vivinex Impress XY1-EM IOL, and returned for final follow-up. Follow-up occurred between 30 and 90 days postoperatively, at which manifest refractive spherical equivalent (MRSE), binocular uncorrected visual acuities, defocus curve, corneal wavefront aberrometry, pupil size, IOL tilt and decentration, near stereopsis, photic phenomena, and the Visual Functioning-7 questionnaire were evaluated. Results: Postoperative MRSE was −0.14 ± 0.26 diopters (D) and −0.84 ± 0.44 D in dominant and nondominant eyes, respectively. Binocular uncorrected distance visual acuity and uncorrected intermediate visual acuity (at both 80 cm and 66 cm) reached 0.05 logMAR or better, with a mean uncorrected near visual acuity of 0.20 ± 0.11 logMAR. The defocus curve confirmed a broad visual function (≤0.2 logMAR) across a range from +0.50 D to −2.22 D. Intermediate vision was significantly influenced by photopic pupil diameter and corneal spherical aberration ( P < .05). Low levels of IOL tilt, decentration, and corneal higher-order aberrations were observed. Patients reported high visual function (VF-7) and normal stereopsis, without disturbing photic phenomena. Conclusions: Using a new partial-DOFi IOL in a monovision protocol yielded excellent distance to intermediate vision and functional near visual acuity. These results, supported by high subjective visual function and the lack of bothersome photic phenomena, suggest the potential of this strategy for extending the range of vision.
- Open Access
- 1 May 2026
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 52 (5) , 483-490
Visual performance of an EDOF intraocular lens in patients with low to moderate irregular astigmatism
Purpose: To assess visual and subjective outcomes in eyes with low to moderate irregular astigmatism following extended-depth-of-focus (EDOF) intraocular lens (IOL) implantation. Setting: Department of Ophthalmology and Optometry, Medical University of Vienna, Vienna, Austria. Design: Single-center, prospective, clinical trial. Methods: This study assessed patients with low to moderate irregular astigmatism who received bilateral cataract surgery using the nontoric/toric AcrySof IQ Vivity IOL. At the 4-month examination, monocular and binocular corrected distance visual acuity (CDVA) and distance-corrected intermediate visual acuity (DCIVA), monocular 25% low-contrast CDVA and DCIVA, monocular distance-corrected near visual acuity (DCNVA) and corrected near visual acuity (CNVA), monocular defocus curve from +0.5 to −2.5 diopters (D), wavefront aberrometry, and subjective outcome (VF-7) were evaluated. Results: 28 patients presenting low to moderate irregular astigmatism with mean 1.27 ± 0.83 D cylinder and 0.04 ± 0.01 μm/mm 2 root mean square per area were analyzed. At the follow-up visit, mean logMAR results were the following: Monocular CDVA was −0.01 ± 0.08, binocular CDVA was −0.08 ± 0.07, monocular DCIVA was 0.18 ± 0.11, binocular DCIVA was 0.08 ± 0.08, monocular 5% low-contrast CDVA was 0.40 ± 0.12, DCIVA was 0.38 ± 0.11, monocular DCNVA was 0.38 ± 0.09, and CNVA was 0.09 ± 0.09. Monocular defocus curves demonstrated 0.16 ± 0.09 logMAR at −1.5 D of defocus and ≤0.2 logMAR visual acuity up to −1.66 D of defocus. Difficulties during daily life activities (VF-7 questionnaire) were low. Conclusions: In eyes with low to moderate irregular astigmatism, the AcrySof IQ Vivity IOL provided very good monocular and binocular visual performance at far and intermediate distance after bilateral cataract surgery. These findings suggest that low to moderate irregular astigmatism does not substantially decrease visual outcome following bilateral EDOF IOL implantation.
- 1 May 2026
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 52 (5) , 483-490
Open AccessVisual performance of an EDOF intraocular lens in patients with low to moderate irregular astigmatism
Purpose: To assess visual and subjective outcomes in eyes with low to moderate irregular astigmatism following extended-depth-of-focus (EDOF) intraocular lens (IOL) implantation. Setting: Department of Ophthalmology and Optometry, Medical University of Vienna, Vienna, Austria. Design: Single-center, prospective, clinical trial. Methods: This study assessed patients with low to moderate irregular astigmatism who received bilateral cataract surgery using the nontoric/toric AcrySof IQ Vivity IOL. At the 4-month examination, monocular and binocular corrected distance visual acuity (CDVA) and distance-corrected intermediate visual acuity (DCIVA), monocular 25% low-contrast CDVA and DCIVA, monocular distance-corrected near visual acuity (DCNVA) and corrected near visual acuity (CNVA), monocular defocus curve from +0.5 to −2.5 diopters (D), wavefront aberrometry, and subjective outcome (VF-7) were evaluated. Results: 28 patients presenting low to moderate irregular astigmatism with mean 1.27 ± 0.83 D cylinder and 0.04 ± 0.01 μm/mm 2 root mean square per area were analyzed. At the follow-up visit, mean logMAR results were the following: Monocular CDVA was −0.01 ± 0.08, binocular CDVA was −0.08 ± 0.07, monocular DCIVA was 0.18 ± 0.11, binocular DCIVA was 0.08 ± 0.08, monocular 5% low-contrast CDVA was 0.40 ± 0.12, DCIVA was 0.38 ± 0.11, monocular DCNVA was 0.38 ± 0.09, and CNVA was 0.09 ± 0.09. Monocular defocus curves demonstrated 0.16 ± 0.09 logMAR at −1.5 D of defocus and ≤0.2 logMAR visual acuity up to −1.66 D of defocus. Difficulties during daily life activities (VF-7 questionnaire) were low. Conclusions: In eyes with low to moderate irregular astigmatism, the AcrySof IQ Vivity IOL provided very good monocular and binocular visual performance at far and intermediate distance after bilateral cataract surgery. These findings suggest that low to moderate irregular astigmatism does not substantially decrease visual outcome following bilateral EDOF IOL implantation.
- Open Access
- 6 April 2026
- Published by Elsevier in American Journal of Ophthalmology
- Vol. 288, 22-32
Rotational Stability and Refractive Outcomes of a Toric Hydrophilic Acrylic Intraocular Lens
- 6 April 2026
- Published by Elsevier in American Journal of Ophthalmology
- Vol. 288, 22-32
Open AccessRotational Stability and Refractive Outcomes of a Toric Hydrophilic Acrylic Intraocular Lens
- Open Access
- 1 March 2026
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 52 (3) , 275-281
Three-year comparison of two mix-and-match strategies: enhanced monofocal and trifocal vs enhanced monofocal and trifocal EDOF intraocular lenses
Purpose: To assess and compare 3-year visual and subjective outcomes after mix-and-match implantation of enhanced monofocal and trifocal or trifocal extended depth-of-focus (EDOF) intraocular lenses (IOLs). Setting: Department of Ophthalmology and Optometry, Medical University of Vienna, Vienna, Austria. Design: Single-center, prospective, clinical trial. Methods: 50 patients (100 eyes) received bilateral cataract surgery with implantation of the enhanced monofocal Isopure IOL in the dominant eye and either the trifocal Finevision HP or trifocal EDOF Finevision Triumf IOL in the nondominant eye. At the 3-year examination, binocular uncorrected distance visual acuity (UDVA), uncorrected intermediate visual acuity (UIVA) and uncorrected near visual acuity (UNVA), binocular defocus curves, halo/glare simulation, Catquest-9SF questionnaire, spectacle dependence, and Nd:YAG rate were evaluated. Results: 34 patients (68 eyes) were available at the 3-year follow-up examination. In the Isopure-HP group, binocular UDVA, UIVA (80 cm), UIVA (66 cm), and UNVA were −0.04 ± 0.10 (20/20) logMAR, 0.06 ± 0.07 (20/25) logMAR, 0.10 ± 0.08 (20/25) logMAR, and 0.17 ± 0.08 (20/32) logMAR, respectively. Corresponding values in the Isopure-Triumf group were 0.03 ± 0.11 (20/20) logMAR ( P = .08), 0.09 ± 0.10 (20/25) logMAR ( P = .40), 0.12 ± 0.11 (20/25) logMAR ( P = .56), and 0.27 ± 0.07 (20/40) ( P < .001). P values refer to the difference between both groups. Binocular defocus curves showed ≤0.2 logMAR visual acuities up to −3.0 diopters (D) (Isopure-HP) and −2.0 D (Isopure-Triumf). Halo, glare, and Catquest-9SF scores were comparable ( P > .05). Nd:YAG treatment was required in 15 (44%) of Isopure eyes, 2 (13%) of Finevision HP eyes, and 1 (6%) of Finevision Triumf eyes. Conclusions: Combined implantation of enhanced monofocal and trifocal/trifocal EDOF IOLs yields excellent distance and intermediate vision. Near visual acuity and spectacle independence was higher in the Isopure-HP group. Low incidence of photic phenomena and high patient satisfaction highlight the long-term effectiveness of both mix-and-match strategies.
- 1 March 2026
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 52 (3) , 275-281
Open AccessThree-year comparison of two mix-and-match strategies: enhanced monofocal and trifocal vs enhanced monofocal and trifocal EDOF intraocular lenses
Purpose: To assess and compare 3-year visual and subjective outcomes after mix-and-match implantation of enhanced monofocal and trifocal or trifocal extended depth-of-focus (EDOF) intraocular lenses (IOLs). Setting: Department of Ophthalmology and Optometry, Medical University of Vienna, Vienna, Austria. Design: Single-center, prospective, clinical trial. Methods: 50 patients (100 eyes) received bilateral cataract surgery with implantation of the enhanced monofocal Isopure IOL in the dominant eye and either the trifocal Finevision HP or trifocal EDOF Finevision Triumf IOL in the nondominant eye. At the 3-year examination, binocular uncorrected distance visual acuity (UDVA), uncorrected intermediate visual acuity (UIVA) and uncorrected near visual acuity (UNVA), binocular defocus curves, halo/glare simulation, Catquest-9SF questionnaire, spectacle dependence, and Nd:YAG rate were evaluated. Results: 34 patients (68 eyes) were available at the 3-year follow-up examination. In the Isopure-HP group, binocular UDVA, UIVA (80 cm), UIVA (66 cm), and UNVA were −0.04 ± 0.10 (20/20) logMAR, 0.06 ± 0.07 (20/25) logMAR, 0.10 ± 0.08 (20/25) logMAR, and 0.17 ± 0.08 (20/32) logMAR, respectively. Corresponding values in the Isopure-Triumf group were 0.03 ± 0.11 (20/20) logMAR ( P = .08), 0.09 ± 0.10 (20/25) logMAR ( P = .40), 0.12 ± 0.11 (20/25) logMAR ( P = .56), and 0.27 ± 0.07 (20/40) ( P < .001). P values refer to the difference between both groups. Binocular defocus curves showed ≤0.2 logMAR visual acuities up to −3.0 diopters (D) (Isopure-HP) and −2.0 D (Isopure-Triumf). Halo, glare, and Catquest-9SF scores were comparable ( P > .05). Nd:YAG treatment was required in 15 (44%) of Isopure eyes, 2 (13%) of Finevision HP eyes, and 1 (6%) of Finevision Triumf eyes. Conclusions: Combined implantation of enhanced monofocal and trifocal/trifocal EDOF IOLs yields excellent distance and intermediate vision. Near visual acuity and spectacle independence was higher in the Isopure-HP group. Low incidence of photic phenomena and high patient satisfaction highlight the long-term effectiveness of both mix-and-match strategies.
- 1 March 2025
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 51 (3) , 196-203
Assessing postoperative toric intraocular lens rotation: comparative analysis
Purpose: To investigate the accuracy of 3 distinct postoperative toric intraocular lens (TIOL) rotational stability measurement methods. Setting: Department of Ophthalmology and Optometry, Medical University of Vienna, Vienna, Austria. Design: Single-center, prospective, interventional clinical trial. Methods: 128 eyes of 81 patients with age-related cataract received a hydrophobic acrylic TIOL Clareon CNW0T3-9. To evaluate rotational stability, 3 distinct assessment methods were used: (Rotix) comparing the TIOL axis at the end of surgery (EoS) with 1 week and 6 months postoperatively using reference vessels at the sclera, (Slitlamp) comparing the intended axis (IA) with the axis at 1 week and 6 months using slitlamp photography using the horizontal axis as a reference, and (Casia) comparing the IA with the axis at 1 week and 6 months using the axis determination tool of a swept-source anterior segment optical coherence tomographer (Casia 2). Results: Mean absolute rotation from EoS/IA to 6 months differed significantly among Rotix (1.33 ± 1.99 degrees [0.01; 19.80]), Casia (2.88 ± 2.64 degrees [0.00; 19.00]), and Slit-lamp (4.38 ± 3.38 degrees [0.02; 19.38]), as indicated by the Friedman test (χ2 = 71.852, P < .001). Bland-Altman coefficients of repeatability (CoRs) indicated the closest agreement of results between Casia and Rotix, with a CoR of ±3.95 degrees, followed by Slit-lamp and Casia (±6.82 degrees), and finally, between Slit-lamp and Rotix (±7.19 degrees). Conclusions: When assessing true TIOL rotational stability, it is imperative to use fixed anatomical landmarks as a reference and establish a baseline at the EoS. When assessing TIOL rotation along the horizontal axis, considering cyclorotation of the eye is crucial and must not be underestimated.
- 1 March 2025
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 51 (3) , 196-203
Assessing postoperative toric intraocular lens rotation: comparative analysis
Purpose: To investigate the accuracy of 3 distinct postoperative toric intraocular lens (TIOL) rotational stability measurement methods. Setting: Department of Ophthalmology and Optometry, Medical University of Vienna, Vienna, Austria. Design: Single-center, prospective, interventional clinical trial. Methods: 128 eyes of 81 patients with age-related cataract received a hydrophobic acrylic TIOL Clareon CNW0T3-9. To evaluate rotational stability, 3 distinct assessment methods were used: (Rotix) comparing the TIOL axis at the end of surgery (EoS) with 1 week and 6 months postoperatively using reference vessels at the sclera, (Slitlamp) comparing the intended axis (IA) with the axis at 1 week and 6 months using slitlamp photography using the horizontal axis as a reference, and (Casia) comparing the IA with the axis at 1 week and 6 months using the axis determination tool of a swept-source anterior segment optical coherence tomographer (Casia 2). Results: Mean absolute rotation from EoS/IA to 6 months differed significantly among Rotix (1.33 ± 1.99 degrees [0.01; 19.80]), Casia (2.88 ± 2.64 degrees [0.00; 19.00]), and Slit-lamp (4.38 ± 3.38 degrees [0.02; 19.38]), as indicated by the Friedman test (χ2 = 71.852, P < .001). Bland-Altman coefficients of repeatability (CoRs) indicated the closest agreement of results between Casia and Rotix, with a CoR of ±3.95 degrees, followed by Slit-lamp and Casia (±6.82 degrees), and finally, between Slit-lamp and Rotix (±7.19 degrees). Conclusions: When assessing true TIOL rotational stability, it is imperative to use fixed anatomical landmarks as a reference and establish a baseline at the EoS. When assessing TIOL rotation along the horizontal axis, considering cyclorotation of the eye is crucial and must not be underestimated.
- Open Access
- 27 February 2025
- Published by Wiley in Acta Ophthalmologica
- Vol. 103 (5) , e290-e297
Long‐term results after sutureless intrascleral fixation of the Carlevale intraocular lens: Changes in scleral pocket thickness over time
Purpose: To investigate the long‐term effects and dynamic changes in scleral thickness above the T‐haptic after sutureless scleral‐fixated intraocular lens (sSFIOL) implantation using the FIL‐SFF Carlevale lens.Setting: Single‐centre, single‐surgeon, prospective clinical trial, Department of Ophthalmology, Medical University of Vienna, Austria.Methods: Thirty‐six eyes of 36 consecutive patients met the inclusion criteria for this post hoc analysis. Visual acuity, tilt and decentration of the IOL, as well as complications, were evaluated alongside imaging of the scleral pockets during multiple time points using the anterior optical coherence tomography (AS‐OCT) system Tomey CASIA 2 in the bleb mode. The OCT scan pattern, oriented parallel to the T‐shaped haptic of the IOL, facilitated manual analysis of images to measure scleral pocket thickness on both the temporal and nasal haptics. To compensate for distortions and non‐perpendicular image acquisition, distal T‐haptic thickness was also measured to calculate the relative scleral pocket thickness. For statistical evaluation, a linear mixed model was used, where we corrected for multiple measurements.Results: The mean follow‐up period was 28 ± 11 months. Measured scleral thickness above the T‐haptic exhibited a significant decrease on both temporal and nasal sides, translating to an estimated annual decrease of approximately 0.03 mm (p < 0.001). Postoperatively, best‐corrected visual acuity (BCVA) significantly improved from 0.77 ± 0.74 logMAR preoperatively to 0.41 ± 0.60 (p < 0.001). IOL tilt increased slightly from 7.23° ± 3.43° to 7.71° ± 3.70° (p = 0.003), while decentration significantly decreased from 0.41 ± 0.21 to 0.39 ± 0.20 mm (p < 0.001) postoperatively.Conclusions: Long‐term evaluation of Carlevale sSFIOL implantation demonstrated a significant improvement in postoperative BCVA. However, we observed a thinning of the scleral pocket thickness, raising questions about its clinical significance and the viability of subconjunctival placement of T‐haptics in the long term. Further studies are necessary to evaluate the long‐term patency of the scleral pocket.
- 27 February 2025
- Published by Wiley in Acta Ophthalmologica
- Vol. 103 (5) , e290-e297
Open AccessLong‐term results after sutureless intrascleral fixation of the Carlevale intraocular lens: Changes in scleral pocket thickness over time
Purpose: To investigate the long‐term effects and dynamic changes in scleral thickness above the T‐haptic after sutureless scleral‐fixated intraocular lens (sSFIOL) implantation using the FIL‐SFF Carlevale lens.Setting: Single‐centre, single‐surgeon, prospective clinical trial, Department of Ophthalmology, Medical University of Vienna, Austria.Methods: Thirty‐six eyes of 36 consecutive patients met the inclusion criteria for this post hoc analysis. Visual acuity, tilt and decentration of the IOL, as well as complications, were evaluated alongside imaging of the scleral pockets during multiple time points using the anterior optical coherence tomography (AS‐OCT) system Tomey CASIA 2 in the bleb mode. The OCT scan pattern, oriented parallel to the T‐shaped haptic of the IOL, facilitated manual analysis of images to measure scleral pocket thickness on both the temporal and nasal haptics. To compensate for distortions and non‐perpendicular image acquisition, distal T‐haptic thickness was also measured to calculate the relative scleral pocket thickness. For statistical evaluation, a linear mixed model was used, where we corrected for multiple measurements.Results: The mean follow‐up period was 28 ± 11 months. Measured scleral thickness above the T‐haptic exhibited a significant decrease on both temporal and nasal sides, translating to an estimated annual decrease of approximately 0.03 mm (p < 0.001). Postoperatively, best‐corrected visual acuity (BCVA) significantly improved from 0.77 ± 0.74 logMAR preoperatively to 0.41 ± 0.60 (p < 0.001). IOL tilt increased slightly from 7.23° ± 3.43° to 7.71° ± 3.70° (p = 0.003), while decentration significantly decreased from 0.41 ± 0.21 to 0.39 ± 0.20 mm (p < 0.001) postoperatively.Conclusions: Long‐term evaluation of Carlevale sSFIOL implantation demonstrated a significant improvement in postoperative BCVA. However, we observed a thinning of the scleral pocket thickness, raising questions about its clinical significance and the viability of subconjunctival placement of T‐haptics in the long term. Further studies are necessary to evaluate the long‐term patency of the scleral pocket.
- Open Access
- 1 December 2024
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 50 (12) , 1242-1246
Posterior capsule opacification with two similar-design hydrophobic acrylic intraocular lenses: 3-year results of a randomized controlled trial
Purpose: To compare intraindividually the incidence and intensity of posterior capsule opacification (PCO) and Nd:YAG capsulotomy rates between 2 similar open-loop single-piece hydrophobic acrylic intraocular lenses (IOLs) differing slightly in their particular material, optic surface, and sharp posterior edge design over a period of 3 years. Setting: Department of Ophthalmology, Medical University Vienna, Vienna, Austria. Design: Randomized, prospective, patient-masked and examiner-masked clinical trial with intraindividual comparison. Methods: 100 patients randomly received a Vivinex XY1 IOL in 1 eye and a Clareon CNA0T0 IOL in the fellow eye. The amount of PCO (score 0 to 10) was assessed subjectively and objectively with digital retroillumination pictures using automated image analysis software (Automated Quantification of After-Cataract). Corrected distance visual acuity and the presence of glistenings, subjective visual symptoms, and Nd:YAG laser capsulotomy rate were noted. Results: 67 of 100 patients were available for the 3-year follow-up examination. The objective PCO score of the Vivinex XY1 IOLs was 1.0 ± 1.0 compared with the PCO score of 1.5 ± 1.2 for the Clareon CNA0T0 IOLs (P < .001). 7.5% of patients had a Nd:YAG capsulotomy in the Vivinex XY1 eye, and 9.0% had a capsulotomy in the Clareon CNA0T0 eye (P = 1.0). Conclusions: Both hydrophobic acrylic IOLs showed low PCO and YAG rates with a small but significant favor of the Vivinex XY1 IOL compared with the Clareon CNA0T0 IOL. The interaction of various factors such as hydrophobic material, smooth optic surface, and sharp posterior optic edge is the major key for PCO prevention. Clinical Trial Number: NCT 04369482.
- 1 December 2024
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 50 (12) , 1242-1246
Open AccessPosterior capsule opacification with two similar-design hydrophobic acrylic intraocular lenses: 3-year results of a randomized controlled trial
Purpose: To compare intraindividually the incidence and intensity of posterior capsule opacification (PCO) and Nd:YAG capsulotomy rates between 2 similar open-loop single-piece hydrophobic acrylic intraocular lenses (IOLs) differing slightly in their particular material, optic surface, and sharp posterior edge design over a period of 3 years. Setting: Department of Ophthalmology, Medical University Vienna, Vienna, Austria. Design: Randomized, prospective, patient-masked and examiner-masked clinical trial with intraindividual comparison. Methods: 100 patients randomly received a Vivinex XY1 IOL in 1 eye and a Clareon CNA0T0 IOL in the fellow eye. The amount of PCO (score 0 to 10) was assessed subjectively and objectively with digital retroillumination pictures using automated image analysis software (Automated Quantification of After-Cataract). Corrected distance visual acuity and the presence of glistenings, subjective visual symptoms, and Nd:YAG laser capsulotomy rate were noted. Results: 67 of 100 patients were available for the 3-year follow-up examination. The objective PCO score of the Vivinex XY1 IOLs was 1.0 ± 1.0 compared with the PCO score of 1.5 ± 1.2 for the Clareon CNA0T0 IOLs (P < .001). 7.5% of patients had a Nd:YAG capsulotomy in the Vivinex XY1 eye, and 9.0% had a capsulotomy in the Clareon CNA0T0 eye (P = 1.0). Conclusions: Both hydrophobic acrylic IOLs showed low PCO and YAG rates with a small but significant favor of the Vivinex XY1 IOL compared with the Clareon CNA0T0 IOL. The interaction of various factors such as hydrophobic material, smooth optic surface, and sharp posterior optic edge is the major key for PCO prevention. Clinical Trial Number: NCT 04369482.
- Open Access
- 6 June 2024
- Published by Elsevier in American Journal of Ophthalmology
- Vol. 267, 76-83
Fellow-Eye Comparison of Monocular Visual Outcomes Following Monofocal Extended Depth-of-Focus (EDOF) and Trifocal EDOF Intraocular Lens Implantation
- 6 June 2024
- Published by Elsevier in American Journal of Ophthalmology
- Vol. 267, 76-83
Open AccessFellow-Eye Comparison of Monocular Visual Outcomes Following Monofocal Extended Depth-of-Focus (EDOF) and Trifocal EDOF Intraocular Lens Implantation
- Open Access
- 8 November 2023
- Published by Elsevier in American Journal of Ophthalmology
- Vol. 261, 95-102
Intraindividual Comparison of an Enhanced Monofocal and an Aspheric Monofocal Intraocular Lens of the Same Platform
- 8 November 2023
- Published by Elsevier in American Journal of Ophthalmology
- Vol. 261, 95-102
Open AccessIntraindividual Comparison of an Enhanced Monofocal and an Aspheric Monofocal Intraocular Lens of the Same Platform
- 31 July 2023
- Published by Springer Nature in Eye
- Vol. 38 (2) , 321-327
Clinical prospective intra-individual comparison after mix-and-match implantation of a monofocal EDOF and a diffractive trifocal IOL
Objectives To assess intra-individually visual acuity (VA) and subjective outcome after mix-and-match implantation of a monofocal EDOF IOL and a diffractive trifocal IOL. Methods The monofocal EDOF Isopure IOL was implanted in the dominant eye and the trifocal FineVision HP IOL in the non-dominant eye. Postoperative evaluation included VA at various distances, contrast acuity, monocular defocus curves, decentration and tilt, wavefront aberrometry, VF-7 questionnaire and a halo and glare simulator. Results 50 eyes of 25 subjects were enroled. The trifocal IOL performed better at monocular DCNVA (p < 0.01) and at defocus levels of –1.5D to –4.0D (p < 0.01), the monofocal EDOF IOL was better at –0.5D (p = 0.013). No differences in monocular BCDVA, DCIVA, contrast acuity, decentration or tilt were observed (p > 0.05). Wavefront analysis revealed lower HOAs in the trifocal group at 5 mm (p < 0.01) and no difference (p = 0.107) at 3 mm pupil aperture. The monofocal EDOF IOL displayed increased negative SA at 5 mm (p < 0.01) and 3 mm (p < 0.01) pupil diameter. Low values of optical phenomena and satisfying results of the VF-7 questionnaire were obtained. Conclusion Excellent visual performance and low rates of optical phenomena were achieved after mix-and-match implantation of the monofocal EDOF Isopure IOL and the trifocal FineVision HP IOL. Trifocal IOL implantation in the non-dominant eye may decrease optical disturbing phenomena. Similar results were observed for monocular distance, intermediate and contrast VA. The trifocal IOL provided better monocular near VA. Decentration and tilt and HOAs were low.
- 31 July 2023
- Published by Springer Nature in Eye
- Vol. 38 (2) , 321-327
Clinical prospective intra-individual comparison after mix-and-match implantation of a monofocal EDOF and a diffractive trifocal IOL
Objectives To assess intra-individually visual acuity (VA) and subjective outcome after mix-and-match implantation of a monofocal EDOF IOL and a diffractive trifocal IOL. Methods The monofocal EDOF Isopure IOL was implanted in the dominant eye and the trifocal FineVision HP IOL in the non-dominant eye. Postoperative evaluation included VA at various distances, contrast acuity, monocular defocus curves, decentration and tilt, wavefront aberrometry, VF-7 questionnaire and a halo and glare simulator. Results 50 eyes of 25 subjects were enroled. The trifocal IOL performed better at monocular DCNVA (p < 0.01) and at defocus levels of –1.5D to –4.0D (p < 0.01), the monofocal EDOF IOL was better at –0.5D (p = 0.013). No differences in monocular BCDVA, DCIVA, contrast acuity, decentration or tilt were observed (p > 0.05). Wavefront analysis revealed lower HOAs in the trifocal group at 5 mm (p < 0.01) and no difference (p = 0.107) at 3 mm pupil aperture. The monofocal EDOF IOL displayed increased negative SA at 5 mm (p < 0.01) and 3 mm (p < 0.01) pupil diameter. Low values of optical phenomena and satisfying results of the VF-7 questionnaire were obtained. Conclusion Excellent visual performance and low rates of optical phenomena were achieved after mix-and-match implantation of the monofocal EDOF Isopure IOL and the trifocal FineVision HP IOL. Trifocal IOL implantation in the non-dominant eye may decrease optical disturbing phenomena. Similar results were observed for monocular distance, intermediate and contrast VA. The trifocal IOL provided better monocular near VA. Decentration and tilt and HOAs were low.