NMNikolaus Mahnert

Nikolaus Mahnert

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Nikolaus Mahnert has a total of 8 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Prospective evaluation of visual performance of a novel partial–depth-of-field intraocular lens using a monovision strategy

    by Victor Danzinger, Marcus Lisy, Daniel Schartmüller, Nikolaus Mahnert, Markus Schranz, Claudette Abela-Formanek, Christina Leydolt

    Purpose: To assess visual and patient-reported outcomes of a partial–depth-of-field (DOFi) intraocular lens (IOL) using a monovision strategy. Setting: Department of Ophthalmology and Optometry, Medical University of Vienna, Vienna, Austria. Design: Single-center, prospective, clinical trial. Methods: 49 patients underwent bilateral cataract surgery, implantation of the partial-DOFi Vivinex Impress XY1-EM IOL, and returned for final follow-up. Follow-up occurred between 30 and 90 days postoperatively, at which manifest refractive spherical equivalent (MRSE), binocular uncorrected visual acuities, defocus curve, corneal wavefront aberrometry, pupil size, IOL tilt and decentration, near stereopsis, photic phenomena, and the Visual Functioning-7 questionnaire were evaluated. Results: Postoperative MRSE was −0.14 ± 0.26 diopters (D) and −0.84 ± 0.44 D in dominant and nondominant eyes, respectively. Binocular uncorrected distance visual acuity and uncorrected intermediate visual acuity (at both 80 cm and 66 cm) reached 0.05 logMAR or better, with a mean uncorrected near visual acuity of 0.20 ± 0.11 logMAR. The defocus curve confirmed a broad visual function (≤0.2 logMAR) across a range from +0.50 D to −2.22 D. Intermediate vision was significantly influenced by photopic pupil diameter and corneal spherical aberration ( P < .05). Low levels of IOL tilt, decentration, and corneal higher-order aberrations were observed. Patients reported high visual function (VF-7) and normal stereopsis, without disturbing photic phenomena. Conclusions: Using a new partial-DOFi IOL in a monovision protocol yielded excellent distance to intermediate vision and functional near visual acuity. These results, supported by high subjective visual function and the lack of bothersome photic phenomena, suggest the potential of this strategy for extending the range of vision.

  • Open Access

    Visual performance of an EDOF intraocular lens in patients with low to moderate irregular astigmatism

    by Victor Danzinger, Marcus Lisy, Nikolaus Mahnert, Markus Schranz, Claudette Abela-Formanek, Christina Leydolt, Daniel Schartmüller

    Purpose: To assess visual and subjective outcomes in eyes with low to moderate irregular astigmatism following extended-depth-of-focus (EDOF) intraocular lens (IOL) implantation. Setting: Department of Ophthalmology and Optometry, Medical University of Vienna, Vienna, Austria. Design: Single-center, prospective, clinical trial. Methods: This study assessed patients with low to moderate irregular astigmatism who received bilateral cataract surgery using the nontoric/toric AcrySof IQ Vivity IOL. At the 4-month examination, monocular and binocular corrected distance visual acuity (CDVA) and distance-corrected intermediate visual acuity (DCIVA), monocular 25% low-contrast CDVA and DCIVA, monocular distance-corrected near visual acuity (DCNVA) and corrected near visual acuity (CNVA), monocular defocus curve from +0.5 to −2.5 diopters (D), wavefront aberrometry, and subjective outcome (VF-7) were evaluated. Results: 28 patients presenting low to moderate irregular astigmatism with mean 1.27 ± 0.83 D cylinder and 0.04 ± 0.01 μm/mm 2 root mean square per area were analyzed. At the follow-up visit, mean logMAR results were the following: Monocular CDVA was −0.01 ± 0.08, binocular CDVA was −0.08 ± 0.07, monocular DCIVA was 0.18 ± 0.11, binocular DCIVA was 0.08 ± 0.08, monocular 5% low-contrast CDVA was 0.40 ± 0.12, DCIVA was 0.38 ± 0.11, monocular DCNVA was 0.38 ± 0.09, and CNVA was 0.09 ± 0.09. Monocular defocus curves demonstrated 0.16 ± 0.09 logMAR at −1.5 D of defocus and ≤0.2 logMAR visual acuity up to −1.66 D of defocus. Difficulties during daily life activities (VF-7 questionnaire) were low. Conclusions: In eyes with low to moderate irregular astigmatism, the AcrySof IQ Vivity IOL provided very good monocular and binocular visual performance at far and intermediate distance after bilateral cataract surgery. These findings suggest that low to moderate irregular astigmatism does not substantially decrease visual outcome following bilateral EDOF IOL implantation.

  • Open Access

    Rotational Stability and Refractive Outcomes of a Toric Hydrophilic Acrylic Intraocular Lens

    by Marcus Lisy, Nikolaus Mahnert, Markus Schranz, Victor Danzinger, Claudette Abela-Formanek, Christina Leydolt, Rupert Menapace, Daniel Schartmüller


  • Open Access

    Three-year comparison of two mix-and-match strategies: enhanced monofocal and trifocal vs enhanced monofocal and trifocal EDOF intraocular lenses

    by Victor Danzinger, Marcus Lisy, Daniel Schartmüller, Nikolaus Mahnert, Markus Schranz, Claudette Abela-Formanek, Christina Leydolt

    Purpose: To assess and compare 3-year visual and subjective outcomes after mix-and-match implantation of enhanced monofocal and trifocal or trifocal extended depth-of-focus (EDOF) intraocular lenses (IOLs). Setting: Department of Ophthalmology and Optometry, Medical University of Vienna, Vienna, Austria. Design: Single-center, prospective, clinical trial. Methods: 50 patients (100 eyes) received bilateral cataract surgery with implantation of the enhanced monofocal Isopure IOL in the dominant eye and either the trifocal Finevision HP or trifocal EDOF Finevision Triumf IOL in the nondominant eye. At the 3-year examination, binocular uncorrected distance visual acuity (UDVA), uncorrected intermediate visual acuity (UIVA) and uncorrected near visual acuity (UNVA), binocular defocus curves, halo/glare simulation, Catquest-9SF questionnaire, spectacle dependence, and Nd:YAG rate were evaluated. Results: 34 patients (68 eyes) were available at the 3-year follow-up examination. In the Isopure-HP group, binocular UDVA, UIVA (80 cm), UIVA (66 cm), and UNVA were −0.04 ± 0.10 (20/20) logMAR, 0.06 ± 0.07 (20/25) logMAR, 0.10 ± 0.08 (20/25) logMAR, and 0.17 ± 0.08 (20/32) logMAR, respectively. Corresponding values in the Isopure-Triumf group were 0.03 ± 0.11 (20/20) logMAR ( P = .08), 0.09 ± 0.10 (20/25) logMAR ( P = .40), 0.12 ± 0.11 (20/25) logMAR ( P = .56), and 0.27 ± 0.07 (20/40) ( P < .001). P values refer to the difference between both groups. Binocular defocus curves showed ≤0.2 logMAR visual acuities up to −3.0 diopters (D) (Isopure-HP) and −2.0 D (Isopure-Triumf). Halo, glare, and Catquest-9SF scores were comparable ( P > .05). Nd:YAG treatment was required in 15 (44%) of Isopure eyes, 2 (13%) of Finevision HP eyes, and 1 (6%) of Finevision Triumf eyes. Conclusions: Combined implantation of enhanced monofocal and trifocal/trifocal EDOF IOLs yields excellent distance and intermediate vision. Near visual acuity and spectacle independence was higher in the Isopure-HP group. Low incidence of photic phenomena and high patient satisfaction highlight the long-term effectiveness of both mix-and-match strategies.


  • Assessing postoperative toric intraocular lens rotation: comparative analysis

    by Marcus Lisy, Victor Danzinger, Markus Schranz, Nikolaus Mahnert, Claudette Abela-Formanek, Christina Leydolt, Rupert Menapace, Daniel Schartmüller

    Purpose: To investigate the accuracy of 3 distinct postoperative toric intraocular lens (TIOL) rotational stability measurement methods. Setting: Department of Ophthalmology and Optometry, Medical University of Vienna, Vienna, Austria. Design: Single-center, prospective, interventional clinical trial. Methods: 128 eyes of 81 patients with age-related cataract received a hydrophobic acrylic TIOL Clareon CNW0T3-9. To evaluate rotational stability, 3 distinct assessment methods were used: (Rotix) comparing the TIOL axis at the end of surgery (EoS) with 1 week and 6 months postoperatively using reference vessels at the sclera, (Slitlamp) comparing the intended axis (IA) with the axis at 1 week and 6 months using slitlamp photography using the horizontal axis as a reference, and (Casia) comparing the IA with the axis at 1 week and 6 months using the axis determination tool of a swept-source anterior segment optical coherence tomographer (Casia 2). Results: Mean absolute rotation from EoS/IA to 6 months differed significantly among Rotix (1.33 ± 1.99 degrees [0.01; 19.80]), Casia (2.88 ± 2.64 degrees [0.00; 19.00]), and Slit-lamp (4.38 ± 3.38 degrees [0.02; 19.38]), as indicated by the Friedman test (χ2 = 71.852, P < .001). Bland-Altman coefficients of repeatability (CoRs) indicated the closest agreement of results between Casia and Rotix, with a CoR of ±3.95 degrees, followed by Slit-lamp and Casia (±6.82 degrees), and finally, between Slit-lamp and Rotix (±7.19 degrees). Conclusions: When assessing true TIOL rotational stability, it is imperative to use fixed anatomical landmarks as a reference and establish a baseline at the EoS. When assessing TIOL rotation along the horizontal axis, considering cyclorotation of the eye is crucial and must not be underestimated.