JFJean Pierre Faure

Jean Pierre Faure

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Jean Pierre Faure has a total of 23 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Validation of a Novel Gesture Tracking Device for Laparoscopy Surgery Training

    by Siwar Bouzid, Abdelbadia Chaker, Marc Arsicault, Sami Bennour, Jean Pierre Faure, Med Amine Laribi

  • Open Access

    Where to Biopsy to Detect Helicobacter pylori and How Many Biopsies Are Needed to Detect Antibiotic Resistance in a Human Stomach

    by Maxime Pichon, Cong Tri Tran, Gaëtan Motillon, Charlotte Debiais, Sylvain Gautier, Marie Aballea, Julie Cremniter, Philippe Vasseur, David Tougeron, Magali Garcia, et al.

    This study aims to determine the gastric distribution, density, and diversity of Helicobacter pylori infection. Subtotal resection of the stomachs of three H. pylori-infected and asymptomatic obese patients were collected after a sleeve gastrectomy. Distribution and density of H. pylori were determined using culture and RT-PCR on multiple gastric sites (88, 176, and 101 biopsies per patient). Diversity of H. pylori strains was studied using antibiotic susceptibility testing, random amplified polymorphism DNA (RAPD) typing and cagA gene detection on single-colony isolates (44, 96, and 49 isolates per patient). H. pylori was detected in nearly all analyzed sites (354/365 biopsies, 97%). Antral density was higher in one patient only. The three stomachs were almost exclusively infected by an antibiotic-susceptible strain. One clarithromycin-resistant isolate in one biopsy was detected in two stomachs (1/44 and 1/49 isolates), while in the third one, eight (8/96 isolates) metronidazole-resistant isolates were detected. DNA typing showed infection with cagA-negative strains for one patient, cagA-positive strains for a second patient and the third patient was infected with two different strains of distinct cagA genotypes. Infection with H. pylori is shown to spread to the whole surface of the stomach, but a possibility of minor sub-population of antibiotic-resistant clones, undetectable in routine practice.


  • Open Access

    Biomechanical cadaveric comparison of patellar ligament suture protected by a steel cable versus a synthetic cable

    by P. Bouget, C. Breque, J. S. Beranger, J. P. Faure, F. Khiami, T. Vendeuvre

    Purpose and hypothesis: Patellar ligament rupture is a rare disabling pathology requiring a surgical ligament suture protected by a frame. The gold standard is the steel cable, but its rigidity and the necessity of a surgical re-intervention for its removal render it unsatisfactory. The objective of this paper is to quantify the mechanical protection provided by the terylene® in comparison with steel. Twenty-four knees of 12 fresh frozen cadaveric subjects were divided into 2 homogeneous groups (terylene and steel) of 12 knees (mean age = 69.3 years). Proximal ligament repair was performed according to a three-tunnel transosseous reinsertion technique. Mechanical tests were performed in flexion to simulate movement of the knee. The interligament gap and the amplitude angulation of the knee were measured by a system of extensometer and optical goniometer. Mechanical analysis permitted calculation of flexion amplitude for a ligament gap of 1 and 2 mm taking as initial angle the adjusting angle of pretension of the protection frame. Study of deformations of frames was performed. Statistical analysis was performed with a Wilcoxon Mann Whitney test. There is no significant difference in protection of the ligament suture between the “terylene” and “steel” groups. Mean flexion amplitudes (mΔF) show no significant differences between the 2 groups for a distension of the suture of 1 mm (m ΔF terylene1 = 4.74 °; mΔF steel1 = 5.91°; p = 0.198) and 2 mm (mΔF terylene2 = 8.71°; mΔF steel2 = 10.41°; p = 0.114). Elastic deformation of terylene was significantly greater than that of steel (p = 0.0004). Suture protection of the patellar ligament by a terylene wire is not significantly different from that provided by steel frame. The elastic properties of terylene and absence of a need for re intervention to secure its removal lead us towards its use in acute ruptures of the patellar ligament. The main limits involve the properties of the chain extenders with no contraction/muscle shortening and partial dehydration of tendons and ligaments and the mean age of 69.3 years. Level 5.