Ashley Matthies
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ashley Matthies has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Karl Chopra
Homerton University Hospital, London, UK
2 shared publications - Michael Trauer
School of Health and Life Sciences, Teesside University, Middlesbrough, UK
2 shared publications - Robert David Jarman
Emergency Department, Royal Victoria Infirmary, Newcastle upon Tyne, United Kingdom of Great Britain and Northern Ireland
2 shared publications - Anthony Hudson
Department of Emergency Medicine, St George’s University Hospitals NHS Trust, London, UK
1 shared publication - Cian McDermott
Mater University Hospital
1 shared publication - Eleanor de Sausmarez
Kent, Surrey & Sussex Air Ambulance Trust, Wheelbarrow Park Estate, Pattenden Lane, Marden, Kent, TN12 9QJ, UK
1 shared publication
Latest Publications
- Open Access
- 25 July 2024
- Published by Elsevier in Future Healthcare Journal
- Vol. 11 (3) , 100164
Increasing same-day emergency care activity in an existing ambulatory care unit using quality improvement methodology
- 25 July 2024
- Published by Elsevier in Future Healthcare Journal
- Vol. 11 (3) , 100164
Open AccessIncreasing same-day emergency care activity in an existing ambulatory care unit using quality improvement methodology
- 24 July 2023
- Published by BMJ in Emergency Medicine Journal
- Vol. 40 (8) , 605-620
Sudden-onset flank pain
- 24 July 2023
- Published by BMJ in Emergency Medicine Journal
- Vol. 40 (8) , 605-620
Sudden-onset flank pain
- Open Access
- 3 March 2023
- Published by BMJ in Emergency Medicine Journal
- Vol. 40 (6) , 407-417
Diagnostic accuracy of point-of-care lung ultrasound for COVID-19: a systematic review and meta-analysis
Background: Point-of-care (POC) lung ultrasound (LUS) is widely used in the emergency setting and there is an established evidence base across a range of respiratory diseases, including previous viral epidemics. The necessity for rapid testing combined with the limitations of other diagnostic tests has led to the proposal of various potential roles for LUS during the COVID-19 pandemic. This systematic review and meta-analysis focused specifically on the diagnostic accuracy of LUS in adult patients presenting with suspected COVID-19 infection.Methods: Traditional and grey-literature searches were performed on 1 June 2021. Two authors independently carried out the searches, selected studies and completed the Quality Assessment Tool for Diagnostic Test Accuracy Studies (QUADAS-2). Meta-analysis was carried out using established open-source packages inR. We report overall sensitivity, specificity, positive and negative predictive values, and the hierarchical summary receiver operating characteristic curve for LUS. Heterogeneity was determined using the I2statistic.Results: Twenty studies were included, published between October 2020 and April 2021, providing data from a total of 4314 patients. The prevalence and admission rates were generally high across all studies. Overall, LUS was found to be 87.2% sensitive (95% CI 83.6 to 90.2) and 69.5% specific (95% CI 62.2 to 72.5) and demonstrated overall positive and negative likelihood ratios of 3.0 (95% CI 2.3 to 4.1) and 0.16 (95% CI 0.12 to 0.22), respectively. Separate analyses for each reference standard revealed similar sensitivities and specificities for LUS. Heterogeneity was found to be high across the studies. Overall, the quality of studies was low with a high risk of selection bias due to convenience sampling. There were also applicability concerns because all studies were undertaken during a period of high prevalence.Conclusion: During a period of high prevalence, LUS had a sensitivity of 87% for the diagnosis of COVID-19 infection. However, more research is required to confirm these results in more generalisable populations, including those less likely to be admitted to hospital.PROSPERO registration number: CRD42021250464
- 3 March 2023
- Published by BMJ in Emergency Medicine Journal
- Vol. 40 (6) , 407-417
Open AccessDiagnostic accuracy of point-of-care lung ultrasound for COVID-19: a systematic review and meta-analysis
Background: Point-of-care (POC) lung ultrasound (LUS) is widely used in the emergency setting and there is an established evidence base across a range of respiratory diseases, including previous viral epidemics. The necessity for rapid testing combined with the limitations of other diagnostic tests has led to the proposal of various potential roles for LUS during the COVID-19 pandemic. This systematic review and meta-analysis focused specifically on the diagnostic accuracy of LUS in adult patients presenting with suspected COVID-19 infection.Methods: Traditional and grey-literature searches were performed on 1 June 2021. Two authors independently carried out the searches, selected studies and completed the Quality Assessment Tool for Diagnostic Test Accuracy Studies (QUADAS-2). Meta-analysis was carried out using established open-source packages inR. We report overall sensitivity, specificity, positive and negative predictive values, and the hierarchical summary receiver operating characteristic curve for LUS. Heterogeneity was determined using the I2statistic.Results: Twenty studies were included, published between October 2020 and April 2021, providing data from a total of 4314 patients. The prevalence and admission rates were generally high across all studies. Overall, LUS was found to be 87.2% sensitive (95% CI 83.6 to 90.2) and 69.5% specific (95% CI 62.2 to 72.5) and demonstrated overall positive and negative likelihood ratios of 3.0 (95% CI 2.3 to 4.1) and 0.16 (95% CI 0.12 to 0.22), respectively. Separate analyses for each reference standard revealed similar sensitivities and specificities for LUS. Heterogeneity was found to be high across the studies. Overall, the quality of studies was low with a high risk of selection bias due to convenience sampling. There were also applicability concerns because all studies were undertaken during a period of high prevalence.Conclusion: During a period of high prevalence, LUS had a sensitivity of 87% for the diagnosis of COVID-19 infection. However, more research is required to confirm these results in more generalisable populations, including those less likely to be admitted to hospital.PROSPERO registration number: CRD42021250464
- Open Access
Diagnostic accuracy of point-of-care lung ultrasound for COVID-19: A systematic review and meta-analysis
Background: Point-of-care (POC) lung ultrasound (LUS) is widely used in the emergency setting and there is an established evidence base across a range of respiratory diseases, including previous viral epidemics. The necessity for rapid testing combined with the limitations of other diagnostic tests has led to the proposal of various potential roles for LUS during the COVID-19 pandemic. This systematic review and meta-analysis focused specifically on the diagnostic accuracy of LUS in adult patients presenting with suspected COVID-19. Methods: Traditional and grey-literature searches were performed on June 1 st 2021. Two authors independently carried out the searches, selected studies and completed the Quality Assessment Tool for Diagnostic Test Accuracy Studies (QUADAS-2). Meta-analysis was carried out using established open-source packages in R . We report overall sensitivity, specificity, positive and negative predictive values and the hierarchical summary receiver operating characteristic curve for LUS. Heterogeneity was determined using the I 2 statistic. Results: Twenty studies were included, providing data from a total of 4,314 patients. The prevalence and admission rates were generally high across all studies. Overall LUS was found to be 87.2% sensitive (95% CI 83.6-90.2) and 69.5% specific (95% CI 62.2-72.5) and demonstrated overall positive and negative predictive values of 3.0 (95% 2.3-4.1) and 0.16 (95% 0.12-0.22) respectively. Separate analyses for each reference standard revealed similar sensitivities and specificities for LUS. Heterogeneity between studies was found to be high, and QUADAS-2 assessment identified risks of bias in many studies. Conclusion: During a period of high prevalence, LUS is a highly sensitive diagnostic test for COVID-19. However, more research is required to confirm these results in more generalisable populations, including those less likely to be admitted to hospital.
Open AccessDiagnostic accuracy of point-of-care lung ultrasound for COVID-19: A systematic review and meta-analysis
Background: Point-of-care (POC) lung ultrasound (LUS) is widely used in the emergency setting and there is an established evidence base across a range of respiratory diseases, including previous viral epidemics. The necessity for rapid testing combined with the limitations of other diagnostic tests has led to the proposal of various potential roles for LUS during the COVID-19 pandemic. This systematic review and meta-analysis focused specifically on the diagnostic accuracy of LUS in adult patients presenting with suspected COVID-19. Methods: Traditional and grey-literature searches were performed on June 1 st 2021. Two authors independently carried out the searches, selected studies and completed the Quality Assessment Tool for Diagnostic Test Accuracy Studies (QUADAS-2). Meta-analysis was carried out using established open-source packages in R . We report overall sensitivity, specificity, positive and negative predictive values and the hierarchical summary receiver operating characteristic curve for LUS. Heterogeneity was determined using the I 2 statistic. Results: Twenty studies were included, providing data from a total of 4,314 patients. The prevalence and admission rates were generally high across all studies. Overall LUS was found to be 87.2% sensitive (95% CI 83.6-90.2) and 69.5% specific (95% CI 62.2-72.5) and demonstrated overall positive and negative predictive values of 3.0 (95% 2.3-4.1) and 0.16 (95% 0.12-0.22) respectively. Separate analyses for each reference standard revealed similar sensitivities and specificities for LUS. Heterogeneity between studies was found to be high, and QUADAS-2 assessment identified risks of bias in many studies. Conclusion: During a period of high prevalence, LUS is a highly sensitive diagnostic test for COVID-19. However, more research is required to confirm these results in more generalisable populations, including those less likely to be admitted to hospital.
- Open Access
Utility of Lung Ultrasound in COVID-19: A Systematic Scoping Review
Lung ultrasound (LUS) has an established evidence base and has proven useful in previous viral epidemics. An understanding of the utility of LUS in COVID-19 is crucial to determine its most suitable role based on local circumstances. A scoping review was thus undertaken to explore the utility of LUS in COVID-19 and guide future research. 33 studies were identified which represent a rapidly expanding evidence base for LUS in COVID-19. The quality of the included studies was relatively low. However LUS appears to be a highly sensitive and fairly specific test for COVID-19 in all ages and in pregnancy and is almost certainly more sensitive than CXR. The precise diagnostic accuracy of LUS may be influenced by various factors including disease severity, pre-existing lung disease, scanning protocol, operator experience, disease prevalence and the reference standard. High quality research is needed in various fields including: diagnostic accuracy in undifferentiated patients; triage and prognostication; monitoring progression and guiding interventions; persistence of residual LUS findings; inter-observer agreement; and the role of contrast-enhanced LUS.
Open AccessUtility of Lung Ultrasound in COVID-19: A Systematic Scoping Review
Lung ultrasound (LUS) has an established evidence base and has proven useful in previous viral epidemics. An understanding of the utility of LUS in COVID-19 is crucial to determine its most suitable role based on local circumstances. A scoping review was thus undertaken to explore the utility of LUS in COVID-19 and guide future research. 33 studies were identified which represent a rapidly expanding evidence base for LUS in COVID-19. The quality of the included studies was relatively low. However LUS appears to be a highly sensitive and fairly specific test for COVID-19 in all ages and in pregnancy and is almost certainly more sensitive than CXR. The precise diagnostic accuracy of LUS may be influenced by various factors including disease severity, pre-existing lung disease, scanning protocol, operator experience, disease prevalence and the reference standard. High quality research is needed in various fields including: diagnostic accuracy in undifferentiated patients; triage and prognostication; monitoring progression and guiding interventions; persistence of residual LUS findings; inter-observer agreement; and the role of contrast-enhanced LUS.
- Open Access
- 14 February 2017
- Published by Springer Nature in Scandinavian Journal of Trauma, Resuscitation and Emergency Medicine
- Vol. 25 (1) , 1-10
Pre-hospital transfusion of packed red blood cells in 147 patients from a UK helicopter emergency medical service
Early transfusion of packed red blood cells (PRBC) has been associated with improved survival in patients with haemorrhagic shock. This study aims to describe the characteristics of patients receiving pre-hospital blood transfusion and evaluate their subsequent need for in-hospital transfusion and surgery. The decision to administer a pre-hospital PRBC transfusion was based on clinical judgment. All patients transfused pre-hospital PRBC between February 2013 and December 2014 were included. Pre-hospital and in-hospital records were retrospectively reviewed. One hundred forty-seven patients were included. 142 patients had traumatic injuries and 5 patients had haemorrhagic shock from a medical origin. Median Injury Severity Score was 30. 90% of patients receiving PRBC had an ISS of >15. Patients received a mean of 2.4(±1.1) units of PRBC in the pre-hospital phase. Median time from initial emergency call to hospital arrival was 114 min (IQR 103–140). There was significant improvement in systolic (p < 0.001), diastolic (p < 0.001) and mean arterial pressures (p < 0.001) with PRBC transfusion but there was no difference in HR (p = 0.961). Patients received PRBC significantly faster in the field than waiting until hospital arrival. At the receiving hospital 57% required an urgent surgical or interventional radiology procedure. At hospital arrival, patients had a mean lactate of 5.4(±4.4) mmol/L, pH of 6.9(±1.3) and base deficit of −8.1(±6.7). Mean initial serum adjusted calcium was 2.26(±0.29) mmol/L. 89% received further blood products in hospital. No transfusion complications or significant incidents occurred and 100% traceability was achieved. Pre-hospital transfusion of packed red cells has the potential to improvde outcome for trauma patients with major haemorrhage. The pre-hospital time for trauma patients can be several hours, suggesting transfusion needs to start in the pre-hospital phase. Hospital transfusion research suggests a 1:1 ratio of packed red blood cells to plasma improves outcome and further research into pre-hospital adoption of this strategy is needed. Pre-hospital PRBC transfusion significantly reduces the time to transfusion for major trauma patients with suspected major haemorrhage. The majority of patients receiving pre-hospital PRBC were severely injured and required further transfusion in hospital. Further research is warranted to determine which patients are most likely to have outcome benefit from pre-hospital blood products and what triggers should be used for pre-hospital transfusion.
- 14 February 2017
- Published by Springer Nature in Scandinavian Journal of Trauma, Resuscitation and Emergency Medicine
- Vol. 25 (1) , 1-10
Open AccessPre-hospital transfusion of packed red blood cells in 147 patients from a UK helicopter emergency medical service
Early transfusion of packed red blood cells (PRBC) has been associated with improved survival in patients with haemorrhagic shock. This study aims to describe the characteristics of patients receiving pre-hospital blood transfusion and evaluate their subsequent need for in-hospital transfusion and surgery. The decision to administer a pre-hospital PRBC transfusion was based on clinical judgment. All patients transfused pre-hospital PRBC between February 2013 and December 2014 were included. Pre-hospital and in-hospital records were retrospectively reviewed. One hundred forty-seven patients were included. 142 patients had traumatic injuries and 5 patients had haemorrhagic shock from a medical origin. Median Injury Severity Score was 30. 90% of patients receiving PRBC had an ISS of >15. Patients received a mean of 2.4(±1.1) units of PRBC in the pre-hospital phase. Median time from initial emergency call to hospital arrival was 114 min (IQR 103–140). There was significant improvement in systolic (p < 0.001), diastolic (p < 0.001) and mean arterial pressures (p < 0.001) with PRBC transfusion but there was no difference in HR (p = 0.961). Patients received PRBC significantly faster in the field than waiting until hospital arrival. At the receiving hospital 57% required an urgent surgical or interventional radiology procedure. At hospital arrival, patients had a mean lactate of 5.4(±4.4) mmol/L, pH of 6.9(±1.3) and base deficit of −8.1(±6.7). Mean initial serum adjusted calcium was 2.26(±0.29) mmol/L. 89% received further blood products in hospital. No transfusion complications or significant incidents occurred and 100% traceability was achieved. Pre-hospital transfusion of packed red cells has the potential to improvde outcome for trauma patients with major haemorrhage. The pre-hospital time for trauma patients can be several hours, suggesting transfusion needs to start in the pre-hospital phase. Hospital transfusion research suggests a 1:1 ratio of packed red blood cells to plasma improves outcome and further research into pre-hospital adoption of this strategy is needed. Pre-hospital PRBC transfusion significantly reduces the time to transfusion for major trauma patients with suspected major haemorrhage. The majority of patients receiving pre-hospital PRBC were severely injured and required further transfusion in hospital. Further research is warranted to determine which patients are most likely to have outcome benefit from pre-hospital blood products and what triggers should be used for pre-hospital transfusion.