YIYuriko Inagaki

Yuriko Inagaki

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Yuriko Inagaki has a total of 21 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Differences in the Difficulty of Accessing Various 3-Dimensional Locations Under Mirror-Image Conditions During Laparoscopic Surgery

    by Yuriko Inagaki, Kazushige Kawai, Hirofumi Sonoda, Hiroyuki Anzai, Yuzo Nagai, Shinya Abe, Yuichiro Yokoyama, Tsuyoshi Ozawa, Junko Kishikawa, Shigenobu Emoto, et al.

    Background: Laparoscopic colon surgery frequently requires performing maneuvers under mirror-images conditions; the complexity differs depending on the surgical site location in the abdominal cavity. However, no previous reports have examined this. Methods: Eleven surgeons participated in this study. Operations were performed on 25 points placed at the bottom and sides of a laparoscopic training box under mirror-image conditions. The mean time-point required to operate at each point and variation between surgeons were evaluated. Results: When the right hand was used, time-points to touch the right side-superficial ends were 0.50 to 0.58 and 0.27 to 0.45 for the other sites. With the left hand, time-points to touch the left side-superficial ends were 0.58 to 0.63 and 0.28 to 0.51 for the other sites, indicating that the most difficult manipulation was at the proximal site of the surgical port. The variation in the difficulty according to the spots increased with a decrease in the surgeon’s experience (right hand, r=−0.248; left hand, r=−0.491). Conclusions: In performing laparoscopic surgery under mirror-image conditions, the technical difficulty varies by location, and operating in locations close to the forceps port is the most difficult.


  • Open Access

    Analysis of the Positional Relationship Among the Operator, Camera, and Monitor: Overcoming the Difficulties of Mirror-image Conditions During Laparoscopic Surgery

    by Yuriko Inagaki, Kazushige Kawai, Takeshi Nishikawa, Hiroaki Ishii, Shigenobu Emoto, Koji Murono, Manabu Kaneko, Kazuhito Sasaki, Hiroaki Nozawa, Soichiro Ishihara

    Background: Although methods to overcome difficulties associated with mirror-image conditions have been investigated, the ideal spatial relationship among the operator line of sight, monitor location, and camera location remains unclear. Moreover, the best training method for improving laparoscopic surgical skills under varying operator line of sight, camera, and monitor positions is unknown. We aimed to investigate the role of laparoscopic training under mirror-image conditions in improving surgical efficiency and whether prior surgical experience affects such training. Methods: This prospective study was conducted at the Department of Surgical Oncology, Tokyo University, Japan. Twenty-five surgeons participated. Novice (n=14), trained (n=7), and expert (n=4) participants performed the simulated task in a box trainer while varying the positional relationships among the surgeons, camera, and monitor. Five patterns were repeatedly performed 5 times per day for 4 days over 2 weeks. Results: The most significant differences in terms of the time required to complete the task under mirror-image conditions among the 3 groups were on day 1 (novices: 185.8 s, trained: 79.7 s, and experts: 46.5 s, P=0.009). However, after 4 days of training, the corresponding times did not differ among the 3 groups (26.0, 30.7, and 23.1 s, respectively; P=0.415). Laparoscopic training was sufficiently effective under mirror-image conditions. Conclusions: Mirror-image surgical conditions provided the most difficult setting, because surgeons and assistants often became disoriented, and task performance was most degraded. However, just 4 days of training was found to be sufficient to overcome the difficulties encountered while performing laparoscopic procedures under mirror-image conditions.


  • Open Access

    Acute aortic occlusion in a patient with chronic paralysis due to spinal cord injury: a case report

    by Satoshi Yamamoto, Yuriko Yokomizo, Takafumi Akai, Takehiro Chiyoda, Hiroshi Goto, Yukiyoshi Masaki

    Patients with spinal cord injury experience changes in the cardiovascular system and a high morbidity associated with peripheral artery disease. We report a case of acute aortic occlusion in a patient with chronic paralysis due to spinal cord injury. A 65-year-old man with chronic paralysis due to spinal cord injury developed mottling of the right extremity. Because of the complete tetraplegia, the patient had no subjective symptoms. Computed tomography revealed occlusion of the infrarenal abdominal aorta. An emergency thromboembolectomy established adequate blood flow, and the postoperative course was uneventful. The loss of muscle mass might be an advantage in avoiding ischemia reperfusion syndrome. Early detection of acute aortic occlusion and immediate reperfusion are primarily important, but patients with chronic paralysis present a risk of delay in detection, diagnosis, and treatment of acute aortic occlusion because of motor or sensory deficits. Although rare, it is necessary to consider acute aortic occlusion in the case of acute limb ischemia in patients with chronic paralysis due to spinal cord injury.