Felipe Rueda
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Felipe Rueda has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Javier Burguete
Department of Physics and Applied Mathematics, Universidad de Navarra, Pamplona, Spain, Spain
3 shared publications - Luis Fernando Giraldo Cadavid
Fundacion Neumologica Colombiana
3 shared publications - Secundino Fernández
Clinica Universidad de Navarra
3 shared publications - Ana M. Galvis
Rehabilitation Department, Clínica Universidad de La Sabana, Chía, Colombia
2 shared publications - Luis Mauricio Agudelo-Otalora
Engineering School, Universidad de La Sabana, Campus del Puente del Común, Km 7 Autopista Norte de Bogotá, Chía 250001, Cundinamarca, Colombia
2 shared publications - Mario Arbulu
Corporación Unificada Nacional de Educación Superior
2 shared publications
Latest Publications
- 27 July 2017
- Published by Springer Nature in Dysphagia
- Vol. 33 (1) , 15-25
Accuracy of a Laryngopharyngeal Endoscopic Esthesiometer (LPEER) for Evaluating Laryngopharyngeal Mechanosensitivity: A Validation Study in a Prospectively Recruited Cohort of Patients
Recent studies have shown an association between alterations in laryngopharyngeal mechanosensitivity (LPMS) and dysphagia, obstructive sleep apnea, and chronic cough hypersensitivity syndrome. A previous reliability study of a new laryngopharyngeal endoscopic esthesiometer and rangefinder (LPEER) showed high intra- and inter-rater reliability; however, its accuracy has not been tested. We performed an accuracy study of the LPEER in a prospectively and consecutively recruited cohort of 118 patients at two tertiary care university hospitals. Most of the patients were suffering from dysphagia, and all of them underwent a standard clinical evaluation and fiberoptic endoscopic evaluation of swallowing with sensory testing (FEESST) using a new sensory testing protocol. The sensory test included determinations of the laryngeal adductor reflex threshold (LART), the cough reflex threshold (CRT) and the gag reflex threshold (GRT). Abnormalities on these reflex thresholds were evaluated for associations with major alterations in swallowing safety (pharyngeal residues, penetration, and aspiration). We evaluated the discriminative capacity of the LPMS test using ROC curves and the area under the curve (AUC–ROC) and its relationship with the eight-point penetration–aspiration scale (PAS) using the Spearman’s ρ correlation coefficient (SCC). We found a positive correlation between the PAS and LART (SCC 0.47; P < 0.001), CRT (SCC 0.46; P < 0.001) and GRT (SCC 0.34; P = 0.002). The AUC–ROC values for detecting a PAS ≥7 were as follows: LART, 0.83 (P < 0.0001); CRT, 0.79 (P < 0.0001); GRT, 0.72 (P < 0.0001). In this study, the LPEER showed good accuracy for evaluating LPMS. These results justify further validation studies in independent populations.
- 27 July 2017
- Published by Springer Nature in Dysphagia
- Vol. 33 (1) , 15-25
Accuracy of a Laryngopharyngeal Endoscopic Esthesiometer (LPEER) for Evaluating Laryngopharyngeal Mechanosensitivity: A Validation Study in a Prospectively Recruited Cohort of Patients
Recent studies have shown an association between alterations in laryngopharyngeal mechanosensitivity (LPMS) and dysphagia, obstructive sleep apnea, and chronic cough hypersensitivity syndrome. A previous reliability study of a new laryngopharyngeal endoscopic esthesiometer and rangefinder (LPEER) showed high intra- and inter-rater reliability; however, its accuracy has not been tested. We performed an accuracy study of the LPEER in a prospectively and consecutively recruited cohort of 118 patients at two tertiary care university hospitals. Most of the patients were suffering from dysphagia, and all of them underwent a standard clinical evaluation and fiberoptic endoscopic evaluation of swallowing with sensory testing (FEESST) using a new sensory testing protocol. The sensory test included determinations of the laryngeal adductor reflex threshold (LART), the cough reflex threshold (CRT) and the gag reflex threshold (GRT). Abnormalities on these reflex thresholds were evaluated for associations with major alterations in swallowing safety (pharyngeal residues, penetration, and aspiration). We evaluated the discriminative capacity of the LPMS test using ROC curves and the area under the curve (AUC–ROC) and its relationship with the eight-point penetration–aspiration scale (PAS) using the Spearman’s ρ correlation coefficient (SCC). We found a positive correlation between the PAS and LART (SCC 0.47; P < 0.001), CRT (SCC 0.46; P < 0.001) and GRT (SCC 0.34; P = 0.002). The AUC–ROC values for detecting a PAS ≥7 were as follows: LART, 0.83 (P < 0.0001); CRT, 0.79 (P < 0.0001); GRT, 0.72 (P < 0.0001). In this study, the LPEER showed good accuracy for evaluating LPMS. These results justify further validation studies in independent populations.
- 24 March 2017
- Published by Springer Nature in European Archives of Oto-Rhino-Laryngology
- Vol. 274 (7) , 2861-2870
Reliability of a laryngo-pharyngeal esthesiometer and a method for measuring laryngo-pharyngeal mechano-sensitivity in a prospectively recruited cohort of patients
Background There are not reliable methods for measuring laryngo-pharyngeal mechano-sensitivity (LPMS). We aimed to determine the reliability of a new method for measuring LPMS using a new laryngo-pharyngeal esthesiometer (LPEER) in a prospective cohort of dysphagic stroke and non-dysphagic patients. The patients underwent clinical and endoscopic evaluations of swallowing (FESSST). The LPMS assessments consisted of measurements by an expert and a novel rater of the laryngeal-adductor reflex threshold (LART), cough reflex threshold (CRT) and gag reflex threshold (GRT) using the LPEER. We assessed the Bland–Altman limits of agreement, the intraclass correlation coefficients (ICCs) and Spearman correlation coefficients (SCCs). For the inter-rater comparisons, we contrasted the expert and novel raters. A total of 1608 measurements were obtained from 34 dysphagic stroke patients and 33 non-dysphagic patients. The intra-rater ICCs for all reflex thresholds were >0.90. The inter-rater ICCs were 0.87 for the LART, 0.79 for the CRT and 0.70 for the GRT. The intra-rater SCCs for all reflex thresholds were above 0.88 (P < 0.0001). The inter-rater SCC were 0.80 for the LART, 0.79 for the CRT and 0.70 for the GRT (all P < 0.0001). The Bland–Altman plots revealed good agreement for the LART and CRT and moderate agreement for the GRT. The median normal value was 0.14 mN for the LART, 4.4 mN for the CRT and 11.9 mN for the GRT. The median thresholds values in patients with aspiration were LART: 1.31 mN; CRT: 32.9 mN and GRT: 32.9 mN (all P < 0.006 vs normal thresholds). The LPEER exhibited substantial to excellent intra- and inter-rater reliability.
- 24 March 2017
- Published by Springer Nature in European Archives of Oto-Rhino-Laryngology
- Vol. 274 (7) , 2861-2870
Reliability of a laryngo-pharyngeal esthesiometer and a method for measuring laryngo-pharyngeal mechano-sensitivity in a prospectively recruited cohort of patients
Background There are not reliable methods for measuring laryngo-pharyngeal mechano-sensitivity (LPMS). We aimed to determine the reliability of a new method for measuring LPMS using a new laryngo-pharyngeal esthesiometer (LPEER) in a prospective cohort of dysphagic stroke and non-dysphagic patients. The patients underwent clinical and endoscopic evaluations of swallowing (FESSST). The LPMS assessments consisted of measurements by an expert and a novel rater of the laryngeal-adductor reflex threshold (LART), cough reflex threshold (CRT) and gag reflex threshold (GRT) using the LPEER. We assessed the Bland–Altman limits of agreement, the intraclass correlation coefficients (ICCs) and Spearman correlation coefficients (SCCs). For the inter-rater comparisons, we contrasted the expert and novel raters. A total of 1608 measurements were obtained from 34 dysphagic stroke patients and 33 non-dysphagic patients. The intra-rater ICCs for all reflex thresholds were >0.90. The inter-rater ICCs were 0.87 for the LART, 0.79 for the CRT and 0.70 for the GRT. The intra-rater SCCs for all reflex thresholds were above 0.88 (P < 0.0001). The inter-rater SCC were 0.80 for the LART, 0.79 for the CRT and 0.70 for the GRT (all P < 0.0001). The Bland–Altman plots revealed good agreement for the LART and CRT and moderate agreement for the GRT. The median normal value was 0.14 mN for the LART, 4.4 mN for the CRT and 11.9 mN for the GRT. The median thresholds values in patients with aspiration were LART: 1.31 mN; CRT: 32.9 mN and GRT: 32.9 mN (all P < 0.006 vs normal thresholds). The LPEER exhibited substantial to excellent intra- and inter-rater reliability.
- Open Access
- 10 May 2016
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 15 (1) , 1-23
Design, development and validation of a new laryngo-pharyngeal endoscopic esthesiometer and range-finder based on the assessment of air-pulse variability determinants
Laryngo-pharyngeal mechano-sensitivity (LPMS) is involved in dysphagia, sleep apnea, stroke, irritable larynx syndrome and cough hypersensitivity syndrome among other disorders. These conditions are associated with a wide range of airway reflex abnormalities. However, the current device for exploring LPMS is limited because it assesses only the laryngeal adductor reflex during fiber-optic endoscopic evaluations of swallowing and requires a high degree of expertise to obtain reliable results, introducing intrinsic expert variability and subjectivity. We designed, developed and validated a new air-pulse laryngo-pharyngeal endoscopic esthesiometer with a built-in laser range-finder (LPEER) based on the evaluation and control of air-pulse variability determinants and on intrinsic observer variability and subjectivity determinants of the distance, angle and site of stimulus impact. The LPEER was designed to be capable of delivering precise and accurate stimuli with a wide range of intensities that can explore most laryngo-pharyngeal reflexes. We initially explored the potential factors affecting the reliability of LPMS tests and included these factors in a multiple linear regression model. The following factors significantly affected the precision and accuracy of the test (P < 0.001): the tube conducting the air-pulses, the supply pressure of the system, the duration of the air-pulses, and the distance and angle between the end of the tube conducting the air-pulses and the site of impact. To control all of these factors, an LPEER consisting of an air-pulse generator and an endoscopic laser range-finder was designed and manufactured. We assessed the precision and accuracy of the LPEER’s stimulus and range-finder according to the coefficient of variation (CV) and by looking at the differences between the measured properties and the desired values, and we performed a pilot validation on ten human subjects. The air-pulses and range-finder exhibited good precision and accuracy (CV < 0.06), with differences between the desired and measured properties at <3 % and a range-finder measurement error of <1 mm. The tests in patients demonstrated obtainable and reproducible thresholds for the laryngeal adductor, cough and gag reflexes. The new LPEER was capable of delivering precise and accurate stimuli for exploring laryngo-pharyngeal reflexes.
- 10 May 2016
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 15 (1) , 1-23
Open AccessDesign, development and validation of a new laryngo-pharyngeal endoscopic esthesiometer and range-finder based on the assessment of air-pulse variability determinants
Laryngo-pharyngeal mechano-sensitivity (LPMS) is involved in dysphagia, sleep apnea, stroke, irritable larynx syndrome and cough hypersensitivity syndrome among other disorders. These conditions are associated with a wide range of airway reflex abnormalities. However, the current device for exploring LPMS is limited because it assesses only the laryngeal adductor reflex during fiber-optic endoscopic evaluations of swallowing and requires a high degree of expertise to obtain reliable results, introducing intrinsic expert variability and subjectivity. We designed, developed and validated a new air-pulse laryngo-pharyngeal endoscopic esthesiometer with a built-in laser range-finder (LPEER) based on the evaluation and control of air-pulse variability determinants and on intrinsic observer variability and subjectivity determinants of the distance, angle and site of stimulus impact. The LPEER was designed to be capable of delivering precise and accurate stimuli with a wide range of intensities that can explore most laryngo-pharyngeal reflexes. We initially explored the potential factors affecting the reliability of LPMS tests and included these factors in a multiple linear regression model. The following factors significantly affected the precision and accuracy of the test (P < 0.001): the tube conducting the air-pulses, the supply pressure of the system, the duration of the air-pulses, and the distance and angle between the end of the tube conducting the air-pulses and the site of impact. To control all of these factors, an LPEER consisting of an air-pulse generator and an endoscopic laser range-finder was designed and manufactured. We assessed the precision and accuracy of the LPEER’s stimulus and range-finder according to the coefficient of variation (CV) and by looking at the differences between the measured properties and the desired values, and we performed a pilot validation on ten human subjects. The air-pulses and range-finder exhibited good precision and accuracy (CV < 0.06), with differences between the desired and measured properties at <3 % and a range-finder measurement error of <1 mm. The tests in patients demonstrated obtainable and reproducible thresholds for the laryngeal adductor, cough and gag reflexes. The new LPEER was capable of delivering precise and accurate stimuli for exploring laryngo-pharyngeal reflexes.