Juliane Stuth
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Juliane Stuth has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Belinda Stock
Department of Cellular Therapeutics (GMP), German Red Cross Blood Service Baden-Württemberg-Hesse, Institute Frankfurt, Frankfurt, Germany
1 shared publication - Carolin Poppe
Institute Frankfurt, German Red Cross Blood Service Baden-Württemberg-Hessen, Sandhofstr. 1, 60528, Frankfurt, Germany
1 shared publication - Christiane Hümmer
Institute Frankfurt, German Red Cross Blood Service Baden-Württemberg-Hessen, Sandhofstr. 1, 60528, Frankfurt, Germany
1 shared publication - Erhard Seifried
13Institute of Transfusion Medicine and Immunohematology, German Red Cross Blood Transfusion Service Baden-Württemberg – Hessen, Frankfurt, Germany
1 shared publication - Eva Wingenfeld
Institute Frankfurt, German Red Cross Blood Service Baden-Württemberg-Hessen, Sandhofstr. 1, 60528, Frankfurt, Germany
1 shared publication - Halvard Bonig
Institute for Transfusion Medicine and Immunohematology, Goethe University and German Red Cross Blood Service BaWueHe, Frankfurt, Germany
1 shared publication
Latest Publications
- Open Access
- 16 March 2016
- Published by Springer Nature in Journal of Translational Medicine
- Vol. 14 (1) , 1-7
Automation of cellular therapy product manufacturing: results of a split validation comparing CD34 selection of peripheral blood stem cell apheresis product with a semi-manual vs. an automatic procedure
Automation of cell therapy manufacturing promises higher productivity of cell factories, more economical use of highly-trained (and costly) manufacturing staff, facilitation of processes requiring manufacturing steps at inconvenient hours, improved consistency of processing steps and other benefits. One of the most broadly disseminated engineered cell therapy products is immunomagnetically selected CD34+ hematopoietic “stem” cells (HSCs). As the clinical GMP-compliant automat CliniMACS Prodigy is being programmed to perform ever more complex sequential manufacturing steps, we developed a CD34+ selection module for comparison with the standard semi-automatic CD34 “normal scale” selection process on CliniMACS Plus, applicable for 600 × 106 target cells out of 60 × 109 total cells. Three split-validation processings with healthy donor G-CSF-mobilized apheresis products were performed; feasibility, time consumption and product quality were assessed. All processes proceeded uneventfully. Prodigy runs took about 1 h longer than CliniMACS Plus runs, albeit with markedly less hands-on operator time and therefore also suitable for less experienced operators. Recovery of target cells was the same for both technologies. Although impurities, specifically T- and B-cells, were 5 ± 1.6-fold and 4 ± 0.4-fold higher in the Prodigy products (p = ns and p = 0.013 for T and B cell depletion, respectively), T cell contents per kg of a virtual recipient receiving 4 × 106 CD34+ cells/kg was below 10 × 103/kg even in the worst Prodigy product and thus more than fivefold below the specification of CD34+ selected mismatched-donor stem cell products. The products’ theoretical clinical usability is thus confirmed. This split validation exercise of a relatively short and simple process exemplifies the potential of automatic cell manufacturing. Automation will further gain in attractiveness when applied to more complex processes, requiring frequent interventions or handling at unfavourable working hours, such as re-targeting of T-cells.
- 16 March 2016
- Published by Springer Nature in Journal of Translational Medicine
- Vol. 14 (1) , 1-7
Open AccessAutomation of cellular therapy product manufacturing: results of a split validation comparing CD34 selection of peripheral blood stem cell apheresis product with a semi-manual vs. an automatic procedure
Automation of cell therapy manufacturing promises higher productivity of cell factories, more economical use of highly-trained (and costly) manufacturing staff, facilitation of processes requiring manufacturing steps at inconvenient hours, improved consistency of processing steps and other benefits. One of the most broadly disseminated engineered cell therapy products is immunomagnetically selected CD34+ hematopoietic “stem” cells (HSCs). As the clinical GMP-compliant automat CliniMACS Prodigy is being programmed to perform ever more complex sequential manufacturing steps, we developed a CD34+ selection module for comparison with the standard semi-automatic CD34 “normal scale” selection process on CliniMACS Plus, applicable for 600 × 106 target cells out of 60 × 109 total cells. Three split-validation processings with healthy donor G-CSF-mobilized apheresis products were performed; feasibility, time consumption and product quality were assessed. All processes proceeded uneventfully. Prodigy runs took about 1 h longer than CliniMACS Plus runs, albeit with markedly less hands-on operator time and therefore also suitable for less experienced operators. Recovery of target cells was the same for both technologies. Although impurities, specifically T- and B-cells, were 5 ± 1.6-fold and 4 ± 0.4-fold higher in the Prodigy products (p = ns and p = 0.013 for T and B cell depletion, respectively), T cell contents per kg of a virtual recipient receiving 4 × 106 CD34+ cells/kg was below 10 × 103/kg even in the worst Prodigy product and thus more than fivefold below the specification of CD34+ selected mismatched-donor stem cell products. The products’ theoretical clinical usability is thus confirmed. This split validation exercise of a relatively short and simple process exemplifies the potential of automatic cell manufacturing. Automation will further gain in attractiveness when applied to more complex processes, requiring frequent interventions or handling at unfavourable working hours, such as re-targeting of T-cells.