Takaaki Kitano
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Takaaki Kitano has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Shigekiyo Matsumoto
Department of Anesthesiology, Faculty of Medicine, Oita University, Yufu, Japan
2 shared publications - Chihiro Shingu
Department of Anesthesiology, Faculty of Medicine, Oita University, Yufu 879-5593, Japan
1 shared publication - Harushi Niu
Department of Medical Technologists, Division of Engineering, Kokura Memorial Hospital, 3-2-1 Asano-Kokura Kitaku, Kitakyushu City, Fukuoka 802-8555 Japan
1 shared publication - Hiroshi Miyawaki
Department of Anesthesiology and Intensive Care Medicine, Kokura Memorial Hospital, 3-2-1 Asano-Kokura Kitaku, Kitakyushu City, Fukuoka 802-8555 Japan
1 shared publication - Junichi Michikoshi
Department of Anesthesiology and Intensive Care, Faculty of Medicine, Oita University, Oita, Japan,
1 shared publication - Katsuhiro Seo
Department of Anesthesiology and Intensive Care Medicine, Kokura Memorial Hospital, 3-2-1 Asano, Kokurakita, Kitakyushu, 802-8555, Japan
1 shared publication
Latest Publications
- Open Access
- 23 June 2022
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (13) , 3633
Incidence, Outcome, and Risk Factors of Cardiovascular Surgery-Associated Disseminated Intravascular Coagulation: A Single-Center Retrospective Study
Cardiovascular surgery is highly invasive, with a risk of postoperative coagulopathy due to various factors such as bleeding. Coagulopathy can progress to disseminated intravascular coagulation (DIC), which complicates various clinical conditions. However, no study to date has reported on DIC associated with cardiovascular surgery. Therefore, we investigated retrospectively the incidence, outcome, and risk factors of cardiovascular surgery-associated DIC in our institute. All patients who underwent cardiovascular surgery and were admitted to our intensive care unit between January 2016 and December 2017 were included in this study. The Japanese Association for Acute Medicine (JAAM) DIC score was calculated using our institute’s database at the following time points: preoperatively, postoperative day 1 (POD1), POD3, and POD7. Data regarding surgery, 90-day mortality, and risk factors of DIC were also collected and analyzed by multiple regression. In total, 553 patients were considered eligible for analysis. Median age of eligible patients was 72 years, with a 90-day mortality rate of 1.4%. Patients with DIC at POD7 had higher Sequential Organ Failure Assessment (SOFA) score, preoperative JAAM DIC scores, and a longer anesthesia time than those without DIC. Female sex, preoperative DIC score, and anesthesia time were found to be risk factors for DIC.
- 23 June 2022
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (13) , 3633
Open AccessIncidence, Outcome, and Risk Factors of Cardiovascular Surgery-Associated Disseminated Intravascular Coagulation: A Single-Center Retrospective Study
Cardiovascular surgery is highly invasive, with a risk of postoperative coagulopathy due to various factors such as bleeding. Coagulopathy can progress to disseminated intravascular coagulation (DIC), which complicates various clinical conditions. However, no study to date has reported on DIC associated with cardiovascular surgery. Therefore, we investigated retrospectively the incidence, outcome, and risk factors of cardiovascular surgery-associated DIC in our institute. All patients who underwent cardiovascular surgery and were admitted to our intensive care unit between January 2016 and December 2017 were included in this study. The Japanese Association for Acute Medicine (JAAM) DIC score was calculated using our institute’s database at the following time points: preoperatively, postoperative day 1 (POD1), POD3, and POD7. Data regarding surgery, 90-day mortality, and risk factors of DIC were also collected and analyzed by multiple regression. In total, 553 patients were considered eligible for analysis. Median age of eligible patients was 72 years, with a 90-day mortality rate of 1.4%. Patients with DIC at POD7 had higher Sequential Organ Failure Assessment (SOFA) score, preoperative JAAM DIC scores, and a longer anesthesia time than those without DIC. Female sex, preoperative DIC score, and anesthesia time were found to be risk factors for DIC.
- Open Access
- 12 January 2016
- Published by Springer Nature in Journal of Intensive Care
- Vol. 4 (1) , 1-7
Performance comparison of a new automated cuff pressure controller with currently available devices in both basic research and clinical settings
The management of tracheal tube cuff pressure in patients receiving mechanical ventilation is important for the prevention of ventilator-associated pneumonia. Currently, cuff pressure is intermittently monitored with a pressure gauge and adjusted when necessary in a routine practice. However, this method results in wide variations in pressure, and adequate management is difficult due to the spontaneous release of air from the cuff, which reduces cuff pressure. In order to continuously maintain a uniform cuff pressure, we developed a new automated cuff pressure controller and compared its properties with existing devices. The effectiveness of the new device was assessed with a model trachea/lung and tracheal tube by measuring cuff pressure while on mechanical ventilation. An electrically powered automatic cuff controller or manual cuff pressure control was used for comparison purposes. The effectiveness of the new device was also examined in patients receiving mechanical ventilation by continuously measuring cuff pressure for a 24-h period. Cuff pressure was uniformly maintained with the new device. Moreover, in the clinical setting, variation in pressure from the set pressure was minimal with both the new device and existing device, relative to the intermittent monitoring method. This suggests that, as with the existing device, uniform cuff pressure management is possible with the new device. Our results demonstrate the ability of the new cuff pressure controller to manage cuff pressure without the need of a power source, highlighting its potential utility in clinical settings.
- 12 January 2016
- Published by Springer Nature in Journal of Intensive Care
- Vol. 4 (1) , 1-7
Open AccessPerformance comparison of a new automated cuff pressure controller with currently available devices in both basic research and clinical settings
The management of tracheal tube cuff pressure in patients receiving mechanical ventilation is important for the prevention of ventilator-associated pneumonia. Currently, cuff pressure is intermittently monitored with a pressure gauge and adjusted when necessary in a routine practice. However, this method results in wide variations in pressure, and adequate management is difficult due to the spontaneous release of air from the cuff, which reduces cuff pressure. In order to continuously maintain a uniform cuff pressure, we developed a new automated cuff pressure controller and compared its properties with existing devices. The effectiveness of the new device was assessed with a model trachea/lung and tracheal tube by measuring cuff pressure while on mechanical ventilation. An electrically powered automatic cuff controller or manual cuff pressure control was used for comparison purposes. The effectiveness of the new device was also examined in patients receiving mechanical ventilation by continuously measuring cuff pressure for a 24-h period. Cuff pressure was uniformly maintained with the new device. Moreover, in the clinical setting, variation in pressure from the set pressure was minimal with both the new device and existing device, relative to the intermittent monitoring method. This suggests that, as with the existing device, uniform cuff pressure management is possible with the new device. Our results demonstrate the ability of the new cuff pressure controller to manage cuff pressure without the need of a power source, highlighting its potential utility in clinical settings.