RWRongxin Wan

Rongxin Wan

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Rongxin Wan has a total of 17 co-authors. Here are the top co-authors by number of shared publications:

  • Hanqing Gu

    Central Laboratory, the Second Hospital of Tianjin Medical University, Tianjin 300211, China

    3 shared publications
  • Dejun Li

    College of Physics and Materials Science, Tianjin Normal University 1 , Tianjin 300387

    2 shared publications
  • Dongsheng Geng

    Jiangsu Key Laboratory of New Energy Devices & Interface Science, School of Chemistry and Materials Science, Nanjing University of Information Science & Technology (NUIST), Nanjing 210000, China

    1 shared publication
  • Guoying Hu

    Central Laboratory, the Second Hospital of Tianjin Medical University, Tianjin 300211, China

    1 shared publication
  • Huiqing Tang

    Central Laboratory, the Second Hospital of Tianjin Medical University, Tianjin 300211, China

    1 shared publication
  • Jiangang Yu

    State Key Laboratory of Extreme Environment Optoelectronic Dynamic Measurement Technology and Instrument, North University of China, Taiyuan 030051, China

    1 shared publication

Latest Publications

  • Open Access

    Influence of Content of Al2O3 on Structure and Properties of Nanocomposite Nb-B-Al-O films

    by Na Liu, Lei Dong, Jiangang Yu, Yupeng Pan, Rongxin Wan, Hanqing Gu, Dejun Li

    Nb-B-Al-O nanocomposite films with different power of Al2O3 were successfully deposited on the Si substrate via multi-target magnetron co-sputtering method. The influences of Al2O3’s content on structure and properties of obtained nanocomposite films through controlling Al2O3’s power were investigated. Increasing the power of Al2O3 can influence the bombarding energy and cause the momentum transfer of NbB2. This can lead to the decreasing content of Al2O3. Furthermore, the whole films showed monocrystalline NbB2’s (100) phase, and Al2O3 shaded from amorphous to weak cubic-crystalline when decreasing content of Al2O3. This structure and content changes were proof by X-ray diffraction (XRD) and high-resolution transmission electron microscopy (TEM) and X-ray photoelectron spectroscopy (XPS). When NbB2 grains were far from each other in lower power of Al2O3, the whole films showed a typical nanocomposite microstructure with crystalline NbB2 grains embedded in a matrix of an amorphous Al2O3 phase. Continuing increasing the power of Al2O3, the less content of Al2O3 tended to cause crystalline of cubic-Al2O3 between the close distances of different crystalline NbB2 grains. The appearance of cubic-crystallization Al2O3 can help to raise the nanocomposite films’ mechanical properties to some extent. The maximum hardness and elastic modulus were up to 21.60 and 332.78 GPa, which were higher than the NbB2 and amorphous Al2O3 monolithic films. Furthermore, this structure change made the chemistry bond of O atom change from the existence of O-Nb, O-B, and O-Al bonds to single O-Al bond and increased the specific value of Al and O. It also influenced the hardness in higher temperature, which made the hardness variation of different Al2O3 content reduced. These results revealed that it can enhance the films’ oxidation resistance properties and keep the mechanical properties at high temperature. The study highlighted the importance of controlling the Al2O3’s content to prepare well-defined films with high mechanical properties and thermal stability.


  • Open Access

    NH2+ implantations induced superior hemocompatibility of carbon nanotubes

    by Meixian Guo, Dejun Li, Mengli Zhao, Yiteng Zhang, Xiangyun Deng, Dongsheng Geng, Ruying Li, Xueliang Sun, Hanqing Gu, Rongxin Wan

    NH2 + implantation was performed on multiwalled carbon nanotubes (MWCNTs) prepared by chemical vapor deposition. The hemocompatibility of MWCNTs and NH2 +-implanted MWCNTs was evaluated based on in vitro hemolysis, platelet adhesion, and kinetic-clotting tests. Compared with MWCNTs, NH2 +-implanted MWCNTs displayed more perfect platelets and red blood cells in morphology, lower platelet adhesion rate, lower hemolytic rate, and longer kinetic blood-clotting time. NH2 +-implanted MWCNTs with higher fluency of 1 × 1016 ions/cm2 led to the best thromboresistance, hence desired hemocompatibility. Fourier transfer infrared and X-ray photoelectron spectroscopy analyses showed that NH2 + implantation caused the cleavage of some pendants and the formation of some new N-containing functional groups. These results were responsible for the enhanced hemocompatibility of NH2 +-implanted MWCNTs.