HGHanqing Gu

Hanqing Gu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Hanqing Gu has a total of 24 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Study on the osteogenesis of rat mesenchymal stem cells and the long‐term antibacterial activity of Staphylococcus epidermidis on the surface of silver‐rich TiN/Ag modified titanium alloy

    by Rongxin Wan, Shanshan Chu, Xiaojuan Wang, Li Lei, Huiqing Tang, Guoying Hu, Lei Dong, Dejun Li, Hanqing Gu

    The main causes of failure of orthopedic implants are infection and poor bone ingrowth. Surface modification of the implants to allow for long‐term antibacterial and osteogenic functions is an effective solution to prevent failure of the implants. We developed silver‐rich TiN/Ag nano‐multilayers on the surface of titanium alloy with different doses of Ag+. The antibacterial stability and osteogenesis of the silver‐rich surface were determined by evaluating the adhesion and proliferation of Staphylococcus epidermidis, and the adhesion, proliferation, alkaline phosphatase activity, extracellular matrix mineralization, and the expression level of genes involved in osteogenic differentiation of rat bone mesenchymal stem cells (BMSCs). The results demonstrated that the antibacterial rates (Ra) of 5 × 1016‐Ag, 1 × 1017‐Ag, 5 × 1017‐Ag, and 1 × 1018‐Ag were respectively 46.21%, 85.66%, 94.99%, 98.48%, and 99.99%. After subcutaneous implantation in rats or immersion in phosphate buffered saline for up to 12 weeks, the silver‐rich surface of the titanium alloy showed long‐term stable inhibition of Staphylococcus epidermidis. Furthermore, in vitro and in vivo studies indicated that the Ag‐implanted titanium did not show apparent cytotoxicity and that lower Ag+ implanted groups (5 × 1016‐Ag, 1 × 1017‐Ag) had better viability and biological safety when compared with higher Ag+ implanted groups. In addition, when compared with the Ti6Al4V‐group, all Ag‐implanted groups exhibited enhanced osteogenic indicators in rat BMSCs. Regarding osteogenic indicators, the surfaces of the 5 × 1017‐Ag group had better osteogenic effects than those of other groups. Therefore, the proper dose of Ag+ implanted TiN/Ag nano‐multilayers may be one of the options for the hard tissue replacement materials with antibacterial activity and osteogenic functions.


  • Open Access

    Influence of Content of Al2O3 on Structure and Properties of Nanocomposite Nb-B-Al-O films

    by Na Liu, Lei Dong, Jiangang Yu, Yupeng Pan, Rongxin Wan, Hanqing Gu, Dejun Li

    Nb-B-Al-O nanocomposite films with different power of Al2O3 were successfully deposited on the Si substrate via multi-target magnetron co-sputtering method. The influences of Al2O3’s content on structure and properties of obtained nanocomposite films through controlling Al2O3’s power were investigated. Increasing the power of Al2O3 can influence the bombarding energy and cause the momentum transfer of NbB2. This can lead to the decreasing content of Al2O3. Furthermore, the whole films showed monocrystalline NbB2’s (100) phase, and Al2O3 shaded from amorphous to weak cubic-crystalline when decreasing content of Al2O3. This structure and content changes were proof by X-ray diffraction (XRD) and high-resolution transmission electron microscopy (TEM) and X-ray photoelectron spectroscopy (XPS). When NbB2 grains were far from each other in lower power of Al2O3, the whole films showed a typical nanocomposite microstructure with crystalline NbB2 grains embedded in a matrix of an amorphous Al2O3 phase. Continuing increasing the power of Al2O3, the less content of Al2O3 tended to cause crystalline of cubic-Al2O3 between the close distances of different crystalline NbB2 grains. The appearance of cubic-crystallization Al2O3 can help to raise the nanocomposite films’ mechanical properties to some extent. The maximum hardness and elastic modulus were up to 21.60 and 332.78 GPa, which were higher than the NbB2 and amorphous Al2O3 monolithic films. Furthermore, this structure change made the chemistry bond of O atom change from the existence of O-Nb, O-B, and O-Al bonds to single O-Al bond and increased the specific value of Al and O. It also influenced the hardness in higher temperature, which made the hardness variation of different Al2O3 content reduced. These results revealed that it can enhance the films’ oxidation resistance properties and keep the mechanical properties at high temperature. The study highlighted the importance of controlling the Al2O3’s content to prepare well-defined films with high mechanical properties and thermal stability.


  • Open Access

    Effect of nitrogen atomic percentage on N+-bombarded MWCNTs in cytocompatibility and hemocompatibility

    by Mengli Zhao, Ye Cao, Xiaoqi Liu, Jianhua Deng, Dejun Li, Hanqing Gu

    N+-bombarded multi-walled carbon nanotubes (N+-bombarded MWCNTs), with different nitrogen atomic percentages, were achieved by different N ion beam currents using ion beam-assisted deposition (IBAD) on MWCNTs synthesized by chemical vapor deposition (CVD). Characterizations of N+-bombarded MWCNTs were evaluated by X-ray photoelectron spectroscopy (XPS), transmission electron microscopy (TEM), Raman spectroscopy, and contact angle. For comparison, the in vitro cytocompatibility of the N+-bombarded MWCNTs with different N atomic percentages was assessed by cellular adhesion investigation using human endothelial cells (EAHY926) and mouse fibroblast cells (L929), respectively. The results showed that the presence of nitrogen in MWCNTs accelerated cell growth and proliferation of cell culture. The higher nitrogen content of N+-bombarded MWCNTs, the better cytocompatibility. In addition, N+-bombarded MWCNTs with higher N atomic percentage displayed lower platelet adhesion rate. No hemolysis can be observed on the surfaces. These results proved that higher N atomic percentage led N+-bombarded MWCNTs to better hemocompatibility.


  • Open Access

    NH2+ implantations induced superior hemocompatibility of carbon nanotubes

    by Meixian Guo, Dejun Li, Mengli Zhao, Yiteng Zhang, Xiangyun Deng, Dongsheng Geng, Ruying Li, Xueliang Sun, Hanqing Gu, Rongxin Wan

    NH2 + implantation was performed on multiwalled carbon nanotubes (MWCNTs) prepared by chemical vapor deposition. The hemocompatibility of MWCNTs and NH2 +-implanted MWCNTs was evaluated based on in vitro hemolysis, platelet adhesion, and kinetic-clotting tests. Compared with MWCNTs, NH2 +-implanted MWCNTs displayed more perfect platelets and red blood cells in morphology, lower platelet adhesion rate, lower hemolytic rate, and longer kinetic blood-clotting time. NH2 +-implanted MWCNTs with higher fluency of 1 × 1016 ions/cm2 led to the best thromboresistance, hence desired hemocompatibility. Fourier transfer infrared and X-ray photoelectron spectroscopy analyses showed that NH2 + implantation caused the cleavage of some pendants and the formation of some new N-containing functional groups. These results were responsible for the enhanced hemocompatibility of NH2 +-implanted MWCNTs.