Juncong Mo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Juncong Mo has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Honglei Pei
Department of Radiation Oncology, The Third Affiliated Hospital of Soochow University, The First Peoples' Hospital of Changzhou, Changzhou, 213003, China.
1 shared publication - Jin-Ming Mu
Department of Radiation Oncology, The Third Affiliated Hospital of Soochow University, The First People's Hospital of Changzhou City, 185 Ju Qian Jie, Changzhou City, 213003, Jiangsu Province, China.
1 shared publication - Min Gao
Department of Radiation Oncology, The Third Affiliated Hospital of Soochow University, The First People's Hospital of Changzhou City, 185 Ju Qian Jie, Changzhou City, 213003, Jiangsu Province, China.
1 shared publication - Qilin Li
Department of Radiation Oncology, The Third Affiliated Hospital of Soochow University, The First People's Hospital of Changzhou City, 185 Ju Qian Jie, Changzhou City, 213003, Jiangsu Province, China.
1 shared publication - Wendong Gu
Department of Radiation Therapy, The First People Hospital of Changzhou, Hefei, China
1 shared publication - Wenming Yin
Department of Radiation Oncology, The Third Affiliated Hospital of Soochow University, The First People's Hospital of Changzhou City, 185 Ju Qian Jie, Changzhou City, 213003, Jiangsu Province, China.
1 shared publication
Latest Publications
- Open Access
- 19 November 2015
- Published by Springer Nature in Radiation Oncology
- Vol. 10 (1) , 235
Collimator rotation in volumetric modulated arc therapy for craniospinal irradiation and the dose distribution in the beam junction region
The purpose of this study was to investigate the role of beam collimator rotation in Volumetric Modulated Arc Therapy (VMAT) for craniospinal irradiation (CSI), and the impact on dose distribution in the beam junctions. Six adult patients were selected for the study. Six VMAT plans with different collimator angles were generated for each patient. The patients were treated in supine position with two beam isocenters. The plans were evaluated by analysis of Dose-Volume Histogram (DVHs) data for planning target volume (PTV) and organs at risk (OAR), and conformity index (CI) and homogeneity index (HI) for the target. Dose distributions in the beam junctions were examined carefully and experimentally validated in phantom, with measurement using an ion chamber array and film. The mean values of HI and CI for the plans with different beam collimator angles were not significantly different. The numbers of segments, monitor units (MUs) and the delivery time of the plans with 45° beam collimator were obviously higher than those in plans with other beam collimator angles. When collimator angle for both sets of beams were set at 0°, there was a 1 mm low dose gap measured in the junction region. By setting the collimator angle to 45°, only two isocenters were needed for the treatment of a target with the length up to 90 cm. The HI and CI of the plans were almost the same, regardless if the collimator angles were at 0°. The collimator angles for at least one set of beams should be off 0° in order to avoid a dose gap in the beam junction region.
- 19 November 2015
- Published by Springer Nature in Radiation Oncology
- Vol. 10 (1) , 235
Open AccessCollimator rotation in volumetric modulated arc therapy for craniospinal irradiation and the dose distribution in the beam junction region
The purpose of this study was to investigate the role of beam collimator rotation in Volumetric Modulated Arc Therapy (VMAT) for craniospinal irradiation (CSI), and the impact on dose distribution in the beam junctions. Six adult patients were selected for the study. Six VMAT plans with different collimator angles were generated for each patient. The patients were treated in supine position with two beam isocenters. The plans were evaluated by analysis of Dose-Volume Histogram (DVHs) data for planning target volume (PTV) and organs at risk (OAR), and conformity index (CI) and homogeneity index (HI) for the target. Dose distributions in the beam junctions were examined carefully and experimentally validated in phantom, with measurement using an ion chamber array and film. The mean values of HI and CI for the plans with different beam collimator angles were not significantly different. The numbers of segments, monitor units (MUs) and the delivery time of the plans with 45° beam collimator were obviously higher than those in plans with other beam collimator angles. When collimator angle for both sets of beams were set at 0°, there was a 1 mm low dose gap measured in the junction region. By setting the collimator angle to 45°, only two isocenters were needed for the treatment of a target with the length up to 90 cm. The HI and CI of the plans were almost the same, regardless if the collimator angles were at 0°. The collimator angles for at least one set of beams should be off 0° in order to avoid a dose gap in the beam junction region.