Uday Bhonsle
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Uday Bhonsle has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Bhaskar Mukherjee
School of Physics, The University of Sydney, NSW, 2006, Australia
1 shared publication - Joe Khachan
School of Physics, University of Sydney 1 , Physics Building, Physics Rd., Camperdown, NSW 2006
1 shared publication - R. Hentschel
Detector and Sensor Group, West German Proton Therapy Centre Essen (WPE), Essen, Germany
1 shared publication - Yaser Hadi Gholami
The University of Sydney
1 shared publication
Latest Publications
- 1 December 2015
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 88 (1056) , 20150035
A unique alpha dosimetry technique using Gafchromic EBT3®film and feasibility study for an activity calibrator for alpha-emitting radiopharmaceuticals
Objective:To develop an alpha dosimetry technique for activity calibration of alpha-emitting radiopharmaceuticals using the Gafchromic® EBT3 (Gaf-EBT3) radiochromic film (International Speciality product, Wayne, NJ).Methods:The Gaf-EBT3 has a tissue equivalent radiosensitive layer (approximately 28 μm) sandwiched between two 100-μm thick polyester sheaths, thereby making it insensitive to alpha particles. We have split a Gaf-EBT3 sheet using a surgical scalpel to remove one of the polyester protective layers and covered the radiosensitive layer with thin Mylar® foil (Goodfellow Cambridge Limited, Huntingdon, UK) (2.5 μm). Small pieces of modified film were exposed at contact with a 560-Bq thin 241Am source for 5, 10, 24 and 94 h. The optical density of the films was evaluated using an optical densitometer. The alpha energy spectra of the 241Am source were recorded using a Si(Li) surface barrier detector.Results:Time-integrated specific alpha surface activity (kBq cm−2 h) was represented as a function of o...
- 1 December 2015
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 88 (1056) , 20150035
A unique alpha dosimetry technique using Gafchromic EBT3®film and feasibility study for an activity calibrator for alpha-emitting radiopharmaceuticals
Objective:To develop an alpha dosimetry technique for activity calibration of alpha-emitting radiopharmaceuticals using the Gafchromic® EBT3 (Gaf-EBT3) radiochromic film (International Speciality product, Wayne, NJ).Methods:The Gaf-EBT3 has a tissue equivalent radiosensitive layer (approximately 28 μm) sandwiched between two 100-μm thick polyester sheaths, thereby making it insensitive to alpha particles. We have split a Gaf-EBT3 sheet using a surgical scalpel to remove one of the polyester protective layers and covered the radiosensitive layer with thin Mylar® foil (Goodfellow Cambridge Limited, Huntingdon, UK) (2.5 μm). Small pieces of modified film were exposed at contact with a 560-Bq thin 241Am source for 5, 10, 24 and 94 h. The optical density of the films was evaluated using an optical densitometer. The alpha energy spectra of the 241Am source were recorded using a Si(Li) surface barrier detector.Results:Time-integrated specific alpha surface activity (kBq cm−2 h) was represented as a function of o...