Sa’aD Fahad Resan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Sa’aD Fahad Resan has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
Musab Sabah Abed
Civil Engineering Department, Engineering College, University of Misan, Amarah, Iraq
3 shared publications- Hayder Al-Khazraji
Department of Civil Engineering , University of Misan , Iraq
2 shared publications Jassim Kadhem Zamel
2 shared publications- Murtada Abass A. Alrubaie
University of Misan
2 shared publications Sajid Kamil Zemam
Civil Engineering Department, Engineering College, University of Misan, Amarah, Iraq
2 shared publications- Sajid Kamil Zemam
Civil Engineering Department, Engineering College, University of Misan, Amarah, Iraq
2 shared publications
Latest Publications
- Open Access
Behavior of Ferrocement Reinforced Concrete Beams Incorporating Waste Glass Exposed to Fire
This study is an experiment that looks at what happens when 18 supported reinforced concrete beams with waste glass inside them are put on fire. All the supported beams were tested under a three-point load. We classified the beams into three groups based on the glass-to-sand replacement ratio. Two sand replacement ratios (10% and 20%) were considered and compared with the control beams (without replacement). Two periods of burning were studied to investigate the mechanical properties of ferrocement and the behavior of simply supported beams. We considered a temperature of 550 °C and gradually increased the burning to reach this degree. Mode failure, mechanical properties, and load–deflection were present in this study. According to this study and its results, it seems that approximately all mode failures were compound flexural and shear failures. The flexural and compressive strength of replacing sand with glass concrete leads to an improvement in the flexural behavior of the reinforced concrete beam incorporating waste glass (brittle failure) that happened when burning the beam element without sand replacement glasses. The replacement ratio (10%) is the best value of the replacement ratio of the glasses; the compressive strength increased by about 10% to 29% by the replacement ratio. When replacing 10% of the sand with glasses, the ratio increases from 1% to 16%, but the compressive strength decreases from 20% to 51% when the burning time increases from one hour to an hour and a half. When 10% of the sand is replaced by glasses by weight, the first crack load capacity goes up by about 8% for one hour of burning and by 16% for one hour and a half of burning compared to beams that are not burning. The ultimate load capacity also goes up by about 17.5% for one hour of burning and by 23.5% for one hour and a half of burning compared to beams that are not burning. Otherwise, sand replacement was 10% by glasses; by weight, the ultimate load strength increased about 6% when the burning was one hour and 12% when the burning was one hour and a half compared with the beams without burning for the same phase.
Open AccessBehavior of Ferrocement Reinforced Concrete Beams Incorporating Waste Glass Exposed to Fire
This study is an experiment that looks at what happens when 18 supported reinforced concrete beams with waste glass inside them are put on fire. All the supported beams were tested under a three-point load. We classified the beams into three groups based on the glass-to-sand replacement ratio. Two sand replacement ratios (10% and 20%) were considered and compared with the control beams (without replacement). Two periods of burning were studied to investigate the mechanical properties of ferrocement and the behavior of simply supported beams. We considered a temperature of 550 °C and gradually increased the burning to reach this degree. Mode failure, mechanical properties, and load–deflection were present in this study. According to this study and its results, it seems that approximately all mode failures were compound flexural and shear failures. The flexural and compressive strength of replacing sand with glass concrete leads to an improvement in the flexural behavior of the reinforced concrete beam incorporating waste glass (brittle failure) that happened when burning the beam element without sand replacement glasses. The replacement ratio (10%) is the best value of the replacement ratio of the glasses; the compressive strength increased by about 10% to 29% by the replacement ratio. When replacing 10% of the sand with glasses, the ratio increases from 1% to 16%, but the compressive strength decreases from 20% to 51% when the burning time increases from one hour to an hour and a half. When 10% of the sand is replaced by glasses by weight, the first crack load capacity goes up by about 8% for one hour of burning and by 16% for one hour and a half of burning compared to beams that are not burning. The ultimate load capacity also goes up by about 17.5% for one hour of burning and by 23.5% for one hour and a half of burning compared to beams that are not burning. Otherwise, sand replacement was 10% by glasses; by weight, the ultimate load strength increased about 6% when the burning was one hour and 12% when the burning was one hour and a half compared with the beams without burning for the same phase.
- 16 November 2024
- Published by Springer Nature
- p. 43-56
Investigating the Behavior of Alternative Rectangle Steel Sections for Longitudinal Reinforcement in RC Columns
- 16 November 2024
- Published by Springer Nature
- p. 43-56
Investigating the Behavior of Alternative Rectangle Steel Sections for Longitudinal Reinforcement in RC Columns
- Open Access
- 2 May 2023
- Published by BioResources in BioResources
- Vol. 18 (3) , 4392-4394
Opportunities of using nanocellulose in construction materials
- 2 May 2023
- Published by BioResources in BioResources
- Vol. 18 (3) , 4392-4394
Open AccessOpportunities of using nanocellulose in construction materials
- Open Access
- 14 January 2023
- Published by Tikrit University in Tikrit Journal of Engineering Sciences
- Vol. 30 (1) , 1-11
Behavior of Multilayer Ferrocement Slab Containing Treated Sponge Layer Core
The current study investigates the structural performance of lightweight concrete panels produced using ferrocement (wire-meshed), hybrid (wire-meshed and steel fiber), and sponge-cementitious immersed layers. These panels presented a novel approach to producing a lightweight concrete panel to be used as an alternative to the traditional Jack-arch masonry slab system. The panels were made in dimensions of 600mm length(l), 200mm width (w), and 54mm thickness (h), using locally available sponge materials and super cementitious mortar incorporated with ferrocement layers. To determine the proper thickness of a sponge layer to be used in panel manufacturing, a material characterization was performed. The obtained results from the material characterization indicated a significant reduction in the density compared with the conventional Jack-arch slab system. The sponge core thickness positively affected the developmental compressive strength. For all sponge thickness modes, the density of developed sponging concrete was within the acceptance criteria of lightweight structural concrete. The average density of developing sponge concrete was 15.6 kN/m3, and the average absorption ratio was 14.78 %, while the density of cementitious mortar was 21.96 kN/m3. As for the structural performance of the resulting lightweight concrete panel, the panel with a hybrid layer (incorporating short steel fiber with steel wire mesh) 10mm layer was the best reinforcement method compared with reinforcing with the wire mesh (ferrocement) solely. Furthermore, the findings of this study depicted that the bending moment capacity of the developed lightweight concrete panel was higher than the conventional Jack-arch masonry usually used in traditional residential housing and lower density.
- 14 January 2023
- Published by Tikrit University in Tikrit Journal of Engineering Sciences
- Vol. 30 (1) , 1-11
Open AccessBehavior of Multilayer Ferrocement Slab Containing Treated Sponge Layer Core
The current study investigates the structural performance of lightweight concrete panels produced using ferrocement (wire-meshed), hybrid (wire-meshed and steel fiber), and sponge-cementitious immersed layers. These panels presented a novel approach to producing a lightweight concrete panel to be used as an alternative to the traditional Jack-arch masonry slab system. The panels were made in dimensions of 600mm length(l), 200mm width (w), and 54mm thickness (h), using locally available sponge materials and super cementitious mortar incorporated with ferrocement layers. To determine the proper thickness of a sponge layer to be used in panel manufacturing, a material characterization was performed. The obtained results from the material characterization indicated a significant reduction in the density compared with the conventional Jack-arch slab system. The sponge core thickness positively affected the developmental compressive strength. For all sponge thickness modes, the density of developed sponging concrete was within the acceptance criteria of lightweight structural concrete. The average density of developing sponge concrete was 15.6 kN/m3, and the average absorption ratio was 14.78 %, while the density of cementitious mortar was 21.96 kN/m3. As for the structural performance of the resulting lightweight concrete panel, the panel with a hybrid layer (incorporating short steel fiber with steel wire mesh) 10mm layer was the best reinforcement method compared with reinforcing with the wire mesh (ferrocement) solely. Furthermore, the findings of this study depicted that the bending moment capacity of the developed lightweight concrete panel was higher than the conventional Jack-arch masonry usually used in traditional residential housing and lower density.
- Open Access
- 1 January 2023
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2784 (1) , 020012
Moment redistribution assessment of continuous reinforced concrete beams of hybrid concrete strength: Experimental study
The current study intends to use moment redistribution concept besides the smart utilization of concrete strength to develop continuous reinforced concrete beam
- 1 January 2023
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2784 (1) , 020012
Open AccessMoment redistribution assessment of continuous reinforced concrete beams of hybrid concrete strength: Experimental study
The current study intends to use moment redistribution concept besides the smart utilization of concrete strength to develop continuous reinforced concrete beam
- 23 January 2022
- Published by Springer Nature in Asian Journal of Civil Engineering
- Vol. 23 (1) , 99-111
Developing knotted slender reinforced concrete column based on bamboo culm biomimicry
- 23 January 2022
- Published by Springer Nature in Asian Journal of Civil Engineering
- Vol. 23 (1) , 99-111
Developing knotted slender reinforced concrete column based on bamboo culm biomimicry
- Open Access
- 1 June 2021
- Published by Elsevier in Case Studies in Construction Materials
- Vol. 14
Rotation capacity assessment in developed non prismatic flanged reinforced concrete Tee beams
- 1 June 2021
- Published by Elsevier in Case Studies in Construction Materials
- Vol. 14
Open AccessRotation capacity assessment in developed non prismatic flanged reinforced concrete Tee beams
- 12 February 2021
- Published by Elsevier in Materials Today: Proceedings
- Vol. 42, 2974-2983
Flexural behavior of developed reinforced concrete beams of non prismatic flanges
- 12 February 2021
- Published by Elsevier in Materials Today: Proceedings
- Vol. 42, 2974-2983
Flexural behavior of developed reinforced concrete beams of non prismatic flanges
- 27 May 2020
- Published by SAGE Publications in Advances in Structural Engineering
- Vol. 23 (12) , 2741-2756
Developing tension field action of embedded steel plates-Stiffened rebars composite reinforcement within concrete deep beams
For reinforced concrete beams, the shear failure mode is confirmed to occur in disturbed regions rather than in the Bernoulli region where stresses can be computed from the flexure formula. Thus, the provision of such regions with shear deficiencies is of great importance. In this study, a tension field system is suggested to embrace the inevitable concrete compression field originating within disturbed regions. Nine rectangular reinforced concrete beams dominated by disturbed regions are tested to verify the proposed shear reinforcement approach of the tension field concept. In this approach, the thin steel plate is embedded within shear span to resist shear strength in two different modes: with and without enhancement of reinforcement as stiffeners. All specimens were tested for failure using a four-point load testing arrangement. Test results demonstrate the feasibility of using embedded mild thin steel plate with and without ribs of rebars as tension field action against initiated concrete compression field action to upgrade the section shear capacity. As depicted by experimental results, the provided tension field system can remarkably upgrade the post cracking, stiffness, and ultimate shear capacity of the considered concrete beams. The stringer panel model is considered to verify and confirm strength improvement. The numerical solution is considered to investigate the proposed composite reinforcement provided within concrete deep beams using the concrete damaged plasticity model. The numerical investigation succeeded to depict the generation of tension field action within the suggested embedded steel plates–stiffened rebars composite reinforcement.
- 27 May 2020
- Published by SAGE Publications in Advances in Structural Engineering
- Vol. 23 (12) , 2741-2756
Developing tension field action of embedded steel plates-Stiffened rebars composite reinforcement within concrete deep beams
For reinforced concrete beams, the shear failure mode is confirmed to occur in disturbed regions rather than in the Bernoulli region where stresses can be computed from the flexure formula. Thus, the provision of such regions with shear deficiencies is of great importance. In this study, a tension field system is suggested to embrace the inevitable concrete compression field originating within disturbed regions. Nine rectangular reinforced concrete beams dominated by disturbed regions are tested to verify the proposed shear reinforcement approach of the tension field concept. In this approach, the thin steel plate is embedded within shear span to resist shear strength in two different modes: with and without enhancement of reinforcement as stiffeners. All specimens were tested for failure using a four-point load testing arrangement. Test results demonstrate the feasibility of using embedded mild thin steel plate with and without ribs of rebars as tension field action against initiated concrete compression field action to upgrade the section shear capacity. As depicted by experimental results, the provided tension field system can remarkably upgrade the post cracking, stiffness, and ultimate shear capacity of the considered concrete beams. The stringer panel model is considered to verify and confirm strength improvement. The numerical solution is considered to investigate the proposed composite reinforcement provided within concrete deep beams using the concrete damaged plasticity model. The numerical investigation succeeded to depict the generation of tension field action within the suggested embedded steel plates–stiffened rebars composite reinforcement.
- 1 September 2019
- Published by Mustansiriyah University College of Engineering in Journal of Engineering and Sustainable Development
- Vol. 23 (5) , 95-107
DEVELOPING SELF-CURING CEMENT SAND MORTAR USING SODIUM POLYACRYLATE
- 1 September 2019
- Published by Mustansiriyah University College of Engineering in Journal of Engineering and Sustainable Development
- Vol. 23 (5) , 95-107
DEVELOPING SELF-CURING CEMENT SAND MORTAR USING SODIUM POLYACRYLATE