Hayder Al-Khazraji
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Hayder Al-Khazraji has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Abbas Oda Dawood
Professor, Dept. of Civil Engineering, College of Engineering, Univ. of Misan, Amarah, Maysan 62001, Iraq. ORCID:
2 shared publications - Abdulkhaliq Abdulyimah Jaafer
Misan University
2 shared publications - Al-Zahraa Hayder Abbood
Department of Civil Engineering , University of Misan , Iraq
2 shared publications - Haider H. Haider
Civil Engineering Department, Engineering College, University of Misan, Amarah 62001, Iraq
2 shared publications - Haider Sattar Faraj
Department of Civil Engineering, Engineering College, University of Misan, Amarah, Iraq
2 shared publications - Majed Ali Mozan
Department of Civil Engineering, Engineering College, University of Misan, Amarah, Iraq
2 shared publications
Latest Publications
- Open Access
- 1 November 2025
- Published by IOP Publishing in IOP Conference Series: Earth and Environmental Science
- Vol. 1545 (1)
Effect of L-Steel Section on Hybrid Deep Beam Performance with Arched Struts
The purpose of this study is to experimentally investigate the impact of alternative shear reinforcement systems on the shear performance of deep beams. Additionally, the research aims to determine the optimal distribution of concrete types in hybrid deep beams to minimize cost and weight while maintaining structural capacity without significant loss. Five beam specimens were cast and divided into two groups. The first group, serving as the control, consisted of two beams: one made of normal-strength concrete and the other of high-strength concrete, both with identical reinforcement details. The second group included three hybrid beams composed of normal- and high-strength concrete, arranged in an arch-shaped hybrid configuration. Angle steel sections (40×40×4 mm) were employed as an alternative to conventional strut reinforcement. All beams shared the same dimensions: 1200 mm in length, 500 mm in depth, and 150 mm in width. The tests were conducted using a single-point loading setup with a constant shear span-to-effective depth ratio (a/d = 1). Compared to the first control beam (normal-strength concrete), the hybrid specimens in the second group exhibited improvements in load-carrying capacity by 40%, 23.3%, and 80%, respectively. Stiffness increased by 54.08%, −15.52%, and 69.76%, while toughness improved by 83.3%, 103.68%, and 215.6%, respectively. In comparison with the second control beam (high-strength concrete), the same hybrid specimens showed increases in load capacity of 7.7%, −5.13%, and 38.46%, respectively. Stiffness improved by 16%, −36.4%, and 27.8%, while toughness increased by 7.3%, 19.93%, and 85.84%, respectively.
- 1 November 2025
- Published by IOP Publishing in IOP Conference Series: Earth and Environmental Science
- Vol. 1545 (1)
Open AccessEffect of L-Steel Section on Hybrid Deep Beam Performance with Arched Struts
The purpose of this study is to experimentally investigate the impact of alternative shear reinforcement systems on the shear performance of deep beams. Additionally, the research aims to determine the optimal distribution of concrete types in hybrid deep beams to minimize cost and weight while maintaining structural capacity without significant loss. Five beam specimens were cast and divided into two groups. The first group, serving as the control, consisted of two beams: one made of normal-strength concrete and the other of high-strength concrete, both with identical reinforcement details. The second group included three hybrid beams composed of normal- and high-strength concrete, arranged in an arch-shaped hybrid configuration. Angle steel sections (40×40×4 mm) were employed as an alternative to conventional strut reinforcement. All beams shared the same dimensions: 1200 mm in length, 500 mm in depth, and 150 mm in width. The tests were conducted using a single-point loading setup with a constant shear span-to-effective depth ratio (a/d = 1). Compared to the first control beam (normal-strength concrete), the hybrid specimens in the second group exhibited improvements in load-carrying capacity by 40%, 23.3%, and 80%, respectively. Stiffness increased by 54.08%, −15.52%, and 69.76%, while toughness improved by 83.3%, 103.68%, and 215.6%, respectively. In comparison with the second control beam (high-strength concrete), the same hybrid specimens showed increases in load capacity of 7.7%, −5.13%, and 38.46%, respectively. Stiffness improved by 16%, −36.4%, and 27.8%, while toughness increased by 7.3%, 19.93%, and 85.84%, respectively.
- 1 January 2024
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 3203 (1) , 050033
Mechanical and physical properties of concrete mixture containing scraped PVC pipes waste as partial sand replacement
This study deals with the effect of using polyvinyl plastic waste (PVC) as a partial replacement for fine aggregate on the physical and mechanical properties of This study deals with the effect of using polyvinyl plastic waste (PVC) as a partial replacement for fine aggregate on the physical and mechanical properties of
- 1 January 2024
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 3203 (1) , 050033
Mechanical and physical properties of concrete mixture containing scraped PVC pipes waste as partial sand replacement
This study deals with the effect of using polyvinyl plastic waste (PVC) as a partial replacement for fine aggregate on the physical and mechanical properties of This study deals with the effect of using polyvinyl plastic waste (PVC) as a partial replacement for fine aggregate on the physical and mechanical properties of
- Open Access
- 1 January 2024
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 3059 (1) , 050003
Flexural strength of reinforced concrete beams of concrete containing iron filings as partial sand replacement
In this study, the effect of using iron filler as a partial substitute for natural sand. Four concrete beams 150×200×1600 mm with similar steel reinforcement (o
- 1 January 2024
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 3059 (1) , 050003
Open AccessFlexural strength of reinforced concrete beams of concrete containing iron filings as partial sand replacement
In this study, the effect of using iron filler as a partial substitute for natural sand. Four concrete beams 150×200×1600 mm with similar steel reinforcement (o
- Open Access
- 12 May 2023
- Published by Walter de Gruyter GmbH in Civil and Environmental Engineering
- Vol. 19 (1) , 248-259
Investigation of Wastes Plastic and Glass to Enhance Physical - Mechanical Properties of Fired Clay Brick
Around the world, large amounts of plastic and glass waste have been collected. This work is given as a way to reduce this material. This paper aims to investigate how fired clay bricks' physical and mechanical properties are affected by plastic/glass ( P/G) powder. It is used as a replacement for clay, varying the plastic/glass content 00/20, 05/15, 10/10, 15/05, and 20/00 weight %. The ratio of soil to water remains constant 0.3. The maximum temperature is presented after three fire phases. The temperatures are 300 °C for the first, 600 °C for the second, and 900 °C for the third. Results for the physical properties showed an increase in the water absorption of clay brick specimens as the plastic content increased; in addition, efflorescence was increased with plastic powder. However, the density and firing shrinkage decrease with plastic quantity. Also, the experimental results showed a decrease in water absorption and efflorescence when the glass powder was increased. While the density is higher when glass powder is 20 %. According to the findings on mechanical properties, clay brick samples with higher plastic powder content 20 % displayed a decrease in compressive strength and flexural bending strength, i. e. the mechanical properties (compressive and flexural strengths) are increased with the increased
- 12 May 2023
- Published by Walter de Gruyter GmbH in Civil and Environmental Engineering
- Vol. 19 (1) , 248-259
Open AccessInvestigation of Wastes Plastic and Glass to Enhance Physical - Mechanical Properties of Fired Clay Brick
Around the world, large amounts of plastic and glass waste have been collected. This work is given as a way to reduce this material. This paper aims to investigate how fired clay bricks' physical and mechanical properties are affected by plastic/glass ( P/G) powder. It is used as a replacement for clay, varying the plastic/glass content 00/20, 05/15, 10/10, 15/05, and 20/00 weight %. The ratio of soil to water remains constant 0.3. The maximum temperature is presented after three fire phases. The temperatures are 300 °C for the first, 600 °C for the second, and 900 °C for the third. Results for the physical properties showed an increase in the water absorption of clay brick specimens as the plastic content increased; in addition, efflorescence was increased with plastic powder. However, the density and firing shrinkage decrease with plastic quantity. Also, the experimental results showed a decrease in water absorption and efflorescence when the glass powder was increased. While the density is higher when glass powder is 20 %. According to the findings on mechanical properties, clay brick samples with higher plastic powder content 20 % displayed a decrease in compressive strength and flexural bending strength, i. e. the mechanical properties (compressive and flexural strengths) are increased with the increased
- 2 February 2023
- Published by Springer Nature in Asian Journal of Civil Engineering
- p. 1-14
New technique used for strengthening jack arch slabs
- 2 February 2023
- Published by Springer Nature in Asian Journal of Civil Engineering
- p. 1-14
New technique used for strengthening jack arch slabs
- Open Access
- 14 January 2023
- Published by Tikrit University in Tikrit Journal of Engineering Sciences
- Vol. 30 (1) , 1-11
Behavior of Multilayer Ferrocement Slab Containing Treated Sponge Layer Core
The current study investigates the structural performance of lightweight concrete panels produced using ferrocement (wire-meshed), hybrid (wire-meshed and steel fiber), and sponge-cementitious immersed layers. These panels presented a novel approach to producing a lightweight concrete panel to be used as an alternative to the traditional Jack-arch masonry slab system. The panels were made in dimensions of 600mm length(l), 200mm width (w), and 54mm thickness (h), using locally available sponge materials and super cementitious mortar incorporated with ferrocement layers. To determine the proper thickness of a sponge layer to be used in panel manufacturing, a material characterization was performed. The obtained results from the material characterization indicated a significant reduction in the density compared with the conventional Jack-arch slab system. The sponge core thickness positively affected the developmental compressive strength. For all sponge thickness modes, the density of developed sponging concrete was within the acceptance criteria of lightweight structural concrete. The average density of developing sponge concrete was 15.6 kN/m3, and the average absorption ratio was 14.78 %, while the density of cementitious mortar was 21.96 kN/m3. As for the structural performance of the resulting lightweight concrete panel, the panel with a hybrid layer (incorporating short steel fiber with steel wire mesh) 10mm layer was the best reinforcement method compared with reinforcing with the wire mesh (ferrocement) solely. Furthermore, the findings of this study depicted that the bending moment capacity of the developed lightweight concrete panel was higher than the conventional Jack-arch masonry usually used in traditional residential housing and lower density.
- 14 January 2023
- Published by Tikrit University in Tikrit Journal of Engineering Sciences
- Vol. 30 (1) , 1-11
Open AccessBehavior of Multilayer Ferrocement Slab Containing Treated Sponge Layer Core
The current study investigates the structural performance of lightweight concrete panels produced using ferrocement (wire-meshed), hybrid (wire-meshed and steel fiber), and sponge-cementitious immersed layers. These panels presented a novel approach to producing a lightweight concrete panel to be used as an alternative to the traditional Jack-arch masonry slab system. The panels were made in dimensions of 600mm length(l), 200mm width (w), and 54mm thickness (h), using locally available sponge materials and super cementitious mortar incorporated with ferrocement layers. To determine the proper thickness of a sponge layer to be used in panel manufacturing, a material characterization was performed. The obtained results from the material characterization indicated a significant reduction in the density compared with the conventional Jack-arch slab system. The sponge core thickness positively affected the developmental compressive strength. For all sponge thickness modes, the density of developed sponging concrete was within the acceptance criteria of lightweight structural concrete. The average density of developing sponge concrete was 15.6 kN/m3, and the average absorption ratio was 14.78 %, while the density of cementitious mortar was 21.96 kN/m3. As for the structural performance of the resulting lightweight concrete panel, the panel with a hybrid layer (incorporating short steel fiber with steel wire mesh) 10mm layer was the best reinforcement method compared with reinforcing with the wire mesh (ferrocement) solely. Furthermore, the findings of this study depicted that the bending moment capacity of the developed lightweight concrete panel was higher than the conventional Jack-arch masonry usually used in traditional residential housing and lower density.
- Open Access
- 1 January 2023
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2784 (1) , 020012
Moment redistribution assessment of continuous reinforced concrete beams of hybrid concrete strength: Experimental study
The current study intends to use moment redistribution concept besides the smart utilization of concrete strength to develop continuous reinforced concrete beam
- 1 January 2023
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2784 (1) , 020012
Open AccessMoment redistribution assessment of continuous reinforced concrete beams of hybrid concrete strength: Experimental study
The current study intends to use moment redistribution concept besides the smart utilization of concrete strength to develop continuous reinforced concrete beam
- Open Access
- 1 December 2022
- Published by Walter de Gruyter GmbH in Civil and Environmental Engineering
- Vol. 18 (2) , 750-759
Utilization of Limestone to Effect on Physical - Mechanical Properties of Fired Clay Brick
Limestone wastes have accumulated in large quantities in countries all over the world. To reduce this materials this work is presented. The goal of this paper is to study the influence of limestone powder on the physical and mechanical of fired clay bricks. It is as replacement of clay, varying the limestone content 5, 10, 15 and 20 wt % . The water / soil ratio is constant 0.3. Three stages of firing are presented to achieve the maximum temperature. The first one is 300 °C and the second one is 600 °C and the last one is 900 °C. Results for the physical properties are showed an increasing of water absorption of clay brick specimens with the limestone content increased, in addition the efflorescence is increased. However, the density and firing shrinkage are decreased with limestone quantity. For the mechanical properties, the results indicate that the clay brick specimens with higher limestone 20 % , showed a decrease in compressive strength and flexural bending strength.
- 1 December 2022
- Published by Walter de Gruyter GmbH in Civil and Environmental Engineering
- Vol. 18 (2) , 750-759
Open AccessUtilization of Limestone to Effect on Physical - Mechanical Properties of Fired Clay Brick
Limestone wastes have accumulated in large quantities in countries all over the world. To reduce this materials this work is presented. The goal of this paper is to study the influence of limestone powder on the physical and mechanical of fired clay bricks. It is as replacement of clay, varying the limestone content 5, 10, 15 and 20 wt % . The water / soil ratio is constant 0.3. Three stages of firing are presented to achieve the maximum temperature. The first one is 300 °C and the second one is 600 °C and the last one is 900 °C. Results for the physical properties are showed an increasing of water absorption of clay brick specimens with the limestone content increased, in addition the efflorescence is increased. However, the density and firing shrinkage are decreased with limestone quantity. For the mechanical properties, the results indicate that the clay brick specimens with higher limestone 20 % , showed a decrease in compressive strength and flexural bending strength.
- Open Access
- 10 November 2022
- Published by Springer Nature in Research Square
New Technique Used for Strengthening Jack Arch Slab
The use of fiber-reinforced polymer rope (FRPR) increases the seismic performance of clay-brick unreinforced masonry slabs and increases the flexural strength of jack arch slabs or roofs. This study examines the bond strength between the clay brick units that make up the jack arch slab and strengthens it using fiber-reinforced polymer rope (FRPR) utilizing a load deflection test. Various parameters were studied, clay brick types affected, span length, camber high and number of injection point (i.e. number of FRPR strengthening are used for each span). The results show the bond strength for jack arch specimens at mid-span for two solid and perforated clay brick slabs gives the most flexural failure. In addition, the increase in the performance of jack arch slabs under line loading (i.e. it is higher deflection) with camber and number of injection.
- 10 November 2022
- Published by Springer Nature in Research Square
Open AccessNew Technique Used for Strengthening Jack Arch Slab
The use of fiber-reinforced polymer rope (FRPR) increases the seismic performance of clay-brick unreinforced masonry slabs and increases the flexural strength of jack arch slabs or roofs. This study examines the bond strength between the clay brick units that make up the jack arch slab and strengthens it using fiber-reinforced polymer rope (FRPR) utilizing a load deflection test. Various parameters were studied, clay brick types affected, span length, camber high and number of injection point (i.e. number of FRPR strengthening are used for each span). The results show the bond strength for jack arch specimens at mid-span for two solid and perforated clay brick slabs gives the most flexural failure. In addition, the increase in the performance of jack arch slabs under line loading (i.e. it is higher deflection) with camber and number of injection.