Sandeep Nalla
Research Subjects
Sandeep Nalla has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Ram B. Basany
Department of Prosthodontics and Crown and Bridge, Sri Venkata Sai (SVS) Institute of Dental Sciences, Mahabubnagar, IND
2 shared publications - Anam Chandra Sekar
Department of Prosthodontics and Crown & Bridge, SVS Institute of Dental Sciences, Mahabubnagar, IND
1 shared publication - Anil G Kumar
Department of Conservative and Endodontics, Saraswati Dhanwantari Dental College and Hospital, Parbhani, (MS), 431401, India
1 shared publication - Ashwini Thandu
Department of Prosthodontics and Crown & Bridge, SVS Institute of Dental Sciences, Mahabubnagar, IND
1 shared publication B Anantha Reddy
Professor, Department of Prosthodontics, SVS Institute of Dental Sciences, Mahabubnagar, Telangana, India
1 shared publicationChandra Sekhar Reddy
Professor, Department of Prosthodontics, Career Postgraduate Institute of Dental Sciences and Hospital, Lucknow, Uttar Pradesh, India
1 shared publication
Latest Publications
- Open Access
- 23 December 2022
- Published by Springer Nature in Cureus
- Vol. 14 (12)
Reliability of Using Texture Analysis of Periapical Radiographs Obtained Using Radiovisiography for Assessing Bone Quality in Dental Implant Planning: A Cross-Sectional Study
Pre-prosthetic implant radiographic imaging helps in the quantitative and qualitative analysis of the bone structure and also enables the evaluation of the relationship between critical structures and potential implant sites. The aim of the study was to define the reliability of utilizing the analysis of textures from the periapical radiographic images obtained through Radiovisiography (RVG) in order to better plan for dental implantations. A cross-sectional study was conducted using 50 intraoral periapical radiographs which were obtained through RVG performed prior to the placement of implants. The radiographs were segregated based on anatomical locations i.e. 12 for the anterior maxilla, nine for the posterior maxilla, seven for the anterior mandible, and 22 for the posterior mandible. Each of the radiographs was visually assessed by four experienced examiners, namely a Prosthodontist E1, Periodontist E2, Oral surgeon E3, and Oral radiologist E4, which was then compared to an experienced operator's tactile perception during a pilot drill for implant placement. As a reference, the Lekholm and Zarb classification was provided to all the examiners for them to qualitatively assess the bone structure in the radiographs. The examiners’ results were correlated with the assessment provided by the experienced operator. E1 and E4 successfully assessed 42% of the radiographs while E2 had the least success with only 26%. Of the 12 anterior maxillary radiographs, only eight were accurately assessed by E1. With respect to the posterior maxilla, all examiners correctly assessed four radiographs each. Of the seven anterior mandibular radiographs, except for E2, the rest correctly assessed three radiographs each. Of the 22 posterior mandibular radiographs, only nine were accurately assessed by E4. Intraoral periapical radiographs obtained through RVG did not meet the desired parameters for assessing the bone quality during the planning stage for implants.
- 23 December 2022
- Published by Springer Nature in Cureus
- Vol. 14 (12)
Open AccessReliability of Using Texture Analysis of Periapical Radiographs Obtained Using Radiovisiography for Assessing Bone Quality in Dental Implant Planning: A Cross-Sectional Study
Pre-prosthetic implant radiographic imaging helps in the quantitative and qualitative analysis of the bone structure and also enables the evaluation of the relationship between critical structures and potential implant sites. The aim of the study was to define the reliability of utilizing the analysis of textures from the periapical radiographic images obtained through Radiovisiography (RVG) in order to better plan for dental implantations. A cross-sectional study was conducted using 50 intraoral periapical radiographs which were obtained through RVG performed prior to the placement of implants. The radiographs were segregated based on anatomical locations i.e. 12 for the anterior maxilla, nine for the posterior maxilla, seven for the anterior mandible, and 22 for the posterior mandible. Each of the radiographs was visually assessed by four experienced examiners, namely a Prosthodontist E1, Periodontist E2, Oral surgeon E3, and Oral radiologist E4, which was then compared to an experienced operator's tactile perception during a pilot drill for implant placement. As a reference, the Lekholm and Zarb classification was provided to all the examiners for them to qualitatively assess the bone structure in the radiographs. The examiners’ results were correlated with the assessment provided by the experienced operator. E1 and E4 successfully assessed 42% of the radiographs while E2 had the least success with only 26%. Of the 12 anterior maxillary radiographs, only eight were accurately assessed by E1. With respect to the posterior maxilla, all examiners correctly assessed four radiographs each. Of the seven anterior mandibular radiographs, except for E2, the rest correctly assessed three radiographs each. Of the 22 posterior mandibular radiographs, only nine were accurately assessed by E4. Intraoral periapical radiographs obtained through RVG did not meet the desired parameters for assessing the bone quality during the planning stage for implants.
- Open Access
- 29 April 2022
- Published by Springer Nature in Cureus
- Vol. 14 (4) , e24591
Biomechanical Evaluation of Stress Distribution in Equicrestal and Sub-crestally Placed, Platform-Switched Morse Taper Dental Implants in D3 Bone: Finite Element Analysis
The aim of the study was to assess the effect of implant placement depth on stress distribution in bone around a platform-switched and Morse taper dental implants placed at the equi-crestal and 1 mm and 2 mm sub-crestal levels in a D3 bone using the 3D finite element analysis. A mechanical model of a partially edentulous maxilla was generated from a computerized tomography (CT) scan of an edentulous patient, as it can give exact bony contours of cortical bone. Also, from accurate geometric measurements obtained from the manufacturer, 3D models of Morse taper and platform-switched implants were manually drawn. The implant and bone models were then superimposed to simulate implant insertion in bone. Three implant positioning levels such as the equi-crestal, 1 mm sub-crestal, and 2 mm sub-crestal models were created, and meshing was done to create the number of elements for distribution of applying loads. The elastic properties of cortical bone and implant, such as Young's modulus and Poisson's ratio (µ), were determined. A load (axial and oblique) of 200N that simulated masticatory force was applied. On comparing stresses within the bone around the equi-crestal and 1 mm and 2 mm sub-crestal implants, it was observed that the maximum stresses were seen within cortical bone around the equi-crestally placed implant (21.694), the least in the 2 mm sub-crestally placed implant (18.85), and intermediate stresses were seen within the 1 mm sub-crestally placed implant (18.876). Sub-crestal (1-2mm) placement of a Morse taper and a platform-switched implant is recommended for long-term success, as maximum von Mises stresses were found within cortical bone around the equi-crestal implant followed by the 1 mm sub-crestal implant and then the 2 mm sub-crestal implant.
- 29 April 2022
- Published by Springer Nature in Cureus
- Vol. 14 (4) , e24591
Open AccessBiomechanical Evaluation of Stress Distribution in Equicrestal and Sub-crestally Placed, Platform-Switched Morse Taper Dental Implants in D3 Bone: Finite Element Analysis
The aim of the study was to assess the effect of implant placement depth on stress distribution in bone around a platform-switched and Morse taper dental implants placed at the equi-crestal and 1 mm and 2 mm sub-crestal levels in a D3 bone using the 3D finite element analysis. A mechanical model of a partially edentulous maxilla was generated from a computerized tomography (CT) scan of an edentulous patient, as it can give exact bony contours of cortical bone. Also, from accurate geometric measurements obtained from the manufacturer, 3D models of Morse taper and platform-switched implants were manually drawn. The implant and bone models were then superimposed to simulate implant insertion in bone. Three implant positioning levels such as the equi-crestal, 1 mm sub-crestal, and 2 mm sub-crestal models were created, and meshing was done to create the number of elements for distribution of applying loads. The elastic properties of cortical bone and implant, such as Young's modulus and Poisson's ratio (µ), were determined. A load (axial and oblique) of 200N that simulated masticatory force was applied. On comparing stresses within the bone around the equi-crestal and 1 mm and 2 mm sub-crestal implants, it was observed that the maximum stresses were seen within cortical bone around the equi-crestally placed implant (21.694), the least in the 2 mm sub-crestally placed implant (18.85), and intermediate stresses were seen within the 1 mm sub-crestally placed implant (18.876). Sub-crestal (1-2mm) placement of a Morse taper and a platform-switched implant is recommended for long-term success, as maximum von Mises stresses were found within cortical bone around the equi-crestal implant followed by the 1 mm sub-crestal implant and then the 2 mm sub-crestal implant.
- Open Access
- 1 September 2015
- Vol. 7 (9) , 18-21
An Analysis of Maxillary Anterior Teeth Dimensions for the Existence of Golden Proportion: Clinical Study
Appearance of the face is a great concern to everyone, as it is a significant part of self-image. The study analyzed the clinical crown dimensions of the maxillary anterior teeth with respect to their apparent mesiodistal widths, width-to-height ratio to determine whether golden proportion existed among the South Indian population. A total of 240 dentulous subjects were chosen for the study (120 males and 120 females) age ranging between 18 and 28 years. Full face and anterior teeth images of the subjects were made on specially designed device resembling a face-bow, mounted onto the wall under a standard light source. The width and height of the maxillary central incisors were measured on the stone casts using a digital caliper. The mean perceived maxillary lateral incisor to central incisor width ratio was 0.67 in males and 0.703 in females. The mean perceived maxillary canine to lateral incisor width ratio was 0.744 in males and 0.714 in females. The mean width-to-height ratio of the maxillary central incisor was 79.49% in males and 79.197% in females. The golden proportion was not found between perceived mesiodistal widths of maxillary central and lateral incisors and nor between perceived mesiodistal widths of maxillary lateral incisors and canines. In the majority of subjects, the width-to-height ratio of maxillary central incisor was within 75-80%. There are no statistically significant differences in maxillary anterior teeth proportions between males and females. The results may serve as guidelines for treatment planning in restorative dentistry and periodontal surgery.
- 1 September 2015
- Vol. 7 (9) , 18-21
Open AccessAn Analysis of Maxillary Anterior Teeth Dimensions for the Existence of Golden Proportion: Clinical Study
Appearance of the face is a great concern to everyone, as it is a significant part of self-image. The study analyzed the clinical crown dimensions of the maxillary anterior teeth with respect to their apparent mesiodistal widths, width-to-height ratio to determine whether golden proportion existed among the South Indian population. A total of 240 dentulous subjects were chosen for the study (120 males and 120 females) age ranging between 18 and 28 years. Full face and anterior teeth images of the subjects were made on specially designed device resembling a face-bow, mounted onto the wall under a standard light source. The width and height of the maxillary central incisors were measured on the stone casts using a digital caliper. The mean perceived maxillary lateral incisor to central incisor width ratio was 0.67 in males and 0.703 in females. The mean perceived maxillary canine to lateral incisor width ratio was 0.744 in males and 0.714 in females. The mean width-to-height ratio of the maxillary central incisor was 79.49% in males and 79.197% in females. The golden proportion was not found between perceived mesiodistal widths of maxillary central and lateral incisors and nor between perceived mesiodistal widths of maxillary lateral incisors and canines. In the majority of subjects, the width-to-height ratio of maxillary central incisor was within 75-80%. There are no statistically significant differences in maxillary anterior teeth proportions between males and females. The results may serve as guidelines for treatment planning in restorative dentistry and periodontal surgery.
- Open Access
- 5 October 2012
- Published by Springer Nature in Head & Face Medicine
- Vol. 8 (1) , 27
A comparative evaluation of dimensional stability of three types of interocclusal recording materials-an in-vitro multi-centre study
Background: The introduction of different interocclusal recording materials has put clinicians in dilemma that which material should be used in routine clinical practice for precise recording and transferring of accurate existing occlusal records for articulation of patient’s diagnostic or working casts in the fabrication of good satisfactory prosthesis. In the era of developing world of dentistry the different materials are introduced for interocclusal record with different brand names because of this; the utility of the material is confusing for successful delivery of prosthesis with lack of in vitro or in vivo studies which will predict the property of the material with utility recommendations. Purpose of the study: The aim of this multicenter research is to evaluate the time dependent linear dimensional stability of three types of interocclusal recording materials; which gives very clear idea to clinicians in regard to its usage in routine practice and recommendations for usage of the different materials. Also to find out ideal time for articulation of three types of interocclusal recording materials with accuracy. Materials and method: Commercially available and ADA approved Polyether bite registration paste (Ramitec), Poly vinyl siloxane bite registration paste (Jetbite) and Zinc oxide eugenol (ZOE) bite registration paste (Super bite) were used in the study. A stainless steel die was made according to modified American dental Associations (ADA) specification no. 19. Each one of the tested materials were manipulated according to manufacturers’ instructions. The materials separated from die, 3-mins after their respective setting time, resulted in disks of standard diameter. Two parallel lines and three perpendicular lines reproduced on the surface. The distance between two parallel lines was measured at different time intervals i.e. 1 hour, 24, 48 and 72 hours by using travelling microscope (magnus) and compared with standard die measurements made according to ADA specification no.19 to find out the dimensional stability of these interocclusal recording materials. Total 120 samples were made for observation and results were subjected to statistical analysis. Statistical analysis was performed using analysis of variance (ANOVA) and then Tukey’s Honestly Significant Difference (HSD) test for comparison among groups at the 0.05 level of significance. After statistical analysis of the data, results were obtained and analyzed for interpretation. Results: The results shows significant difference between the dimensional stability of all three material at different intervals with p-value <0.05. Comparatively the polyether bite registration material showed less distortion with good dimensional stability compared to Poly vinyl siloxane bite (Jetbite), Zinc oxide eugenol(ZOE) bite (Super bite) at 1 hour, 24, 48, and 72 hours. Conclusion: The dimensional stability decreased with increase in time and is influenced by both material factor and time factor. Polyether was found to be more dimensionally stable interocclusal recording material, which was followed by Silicone and Zinc oxide eugenol (ZOE). The dimensional stability of Polyether was good. Zinc oxide eugenol is dimensionally more unstable when compared with polyether and polyvinyl siloxane. We recommend that the polyether interocclusal records must be articulated within 48 hours and Polyvinylsiloxane interocclusal records must be articulated within 24 hours and the ZOE should be articulated within 1 hour to get a correct restoration to have very minimum distortion and maximum satisfaction without failure of prosthesis.
- 5 October 2012
- Published by Springer Nature in Head & Face Medicine
- Vol. 8 (1) , 27
Open AccessA comparative evaluation of dimensional stability of three types of interocclusal recording materials-an in-vitro multi-centre study
Background: The introduction of different interocclusal recording materials has put clinicians in dilemma that which material should be used in routine clinical practice for precise recording and transferring of accurate existing occlusal records for articulation of patient’s diagnostic or working casts in the fabrication of good satisfactory prosthesis. In the era of developing world of dentistry the different materials are introduced for interocclusal record with different brand names because of this; the utility of the material is confusing for successful delivery of prosthesis with lack of in vitro or in vivo studies which will predict the property of the material with utility recommendations. Purpose of the study: The aim of this multicenter research is to evaluate the time dependent linear dimensional stability of three types of interocclusal recording materials; which gives very clear idea to clinicians in regard to its usage in routine practice and recommendations for usage of the different materials. Also to find out ideal time for articulation of three types of interocclusal recording materials with accuracy. Materials and method: Commercially available and ADA approved Polyether bite registration paste (Ramitec), Poly vinyl siloxane bite registration paste (Jetbite) and Zinc oxide eugenol (ZOE) bite registration paste (Super bite) were used in the study. A stainless steel die was made according to modified American dental Associations (ADA) specification no. 19. Each one of the tested materials were manipulated according to manufacturers’ instructions. The materials separated from die, 3-mins after their respective setting time, resulted in disks of standard diameter. Two parallel lines and three perpendicular lines reproduced on the surface. The distance between two parallel lines was measured at different time intervals i.e. 1 hour, 24, 48 and 72 hours by using travelling microscope (magnus) and compared with standard die measurements made according to ADA specification no.19 to find out the dimensional stability of these interocclusal recording materials. Total 120 samples were made for observation and results were subjected to statistical analysis. Statistical analysis was performed using analysis of variance (ANOVA) and then Tukey’s Honestly Significant Difference (HSD) test for comparison among groups at the 0.05 level of significance. After statistical analysis of the data, results were obtained and analyzed for interpretation. Results: The results shows significant difference between the dimensional stability of all three material at different intervals with p-value <0.05. Comparatively the polyether bite registration material showed less distortion with good dimensional stability compared to Poly vinyl siloxane bite (Jetbite), Zinc oxide eugenol(ZOE) bite (Super bite) at 1 hour, 24, 48, and 72 hours. Conclusion: The dimensional stability decreased with increase in time and is influenced by both material factor and time factor. Polyether was found to be more dimensionally stable interocclusal recording material, which was followed by Silicone and Zinc oxide eugenol (ZOE). The dimensional stability of Polyether was good. Zinc oxide eugenol is dimensionally more unstable when compared with polyether and polyvinyl siloxane. We recommend that the polyether interocclusal records must be articulated within 48 hours and Polyvinylsiloxane interocclusal records must be articulated within 24 hours and the ZOE should be articulated within 1 hour to get a correct restoration to have very minimum distortion and maximum satisfaction without failure of prosthesis.