Michael W. Jenkins
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Michael W. Jenkins has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- David L. Wilson
Department of Biomedical Engineering, Case Western Reserve University , 10900 Euclid Avenue, Cleveland, OH 44106
2 shared publications Maryse Lapierre-Landry
Department of Biomedical Engineering, Case Western Reserve University, 10900 Euclid Ave, Cleveland, OH, USA, 44106
2 shared publicationsYehe Liu
Department of Biomedical Engineering, Case Western Reserve University, 10900 Euclid Ave, Cleveland, OH, USA, 44106
2 shared publications- Andrew M.. Rollins
Case Western Reserve University, Department of Biomedical Engineering, Cleveland, Ohio, United States
1 shared publication David L. Wilson
Department of Biomedical Engineering, Case Western Reserve University, 10900 Euclid Ave, Cleveland, OH, USA, 44106
1 shared publication- George C. Linderman
Yale University
1 shared publication
Latest Publications
- 1 January 2023
- Published by Optica Publishing Group
- p. DTh1A.3
Digital Labeling of the Vasculature: Toward Label-Free and Labor-Free Vessel Segmentation
We propose digital labeling, a method for automated, three-dimensional segmentation of blood vessels without vascular contrast agents. Our deep learning approach greatly simplifies the sample preparation required for 3D microscopy and accelerate image post-processing.
- 1 January 2023
- Published by Optica Publishing Group
- p. DTh1A.3
Digital Labeling of the Vasculature: Toward Label-Free and Labor-Free Vessel Segmentation
We propose digital labeling, a method for automated, three-dimensional segmentation of blood vessels without vascular contrast agents. Our deep learning approach greatly simplifies the sample preparation required for 3D microscopy and accelerate image post-processing.
- Open Access
- 19 April 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 60396-60408
Nuclei Detection for 3D Microscopy With a Fully Convolutional Regression Network
Advances in three-dimensional microscopy and tissue clearing are enabling whole-organ imaging with single-cell resolution. Fast and reliable image processing tools are needed to analyze the resulting image volumes, including automated cell detection, cell counting and cell analytics. Deep learning approaches have shown promising results in two- and three-dimensional nuclei detection tasks, however detecting overlapping or non-spherical nuclei of different sizes and shapes in the presence of a blurring point spread function remains challenging and often leads to incorrect nuclei merging and splitting. Here we present a new regression-based fully convolutional network that located a thousand nuclei centroids with high accuracy in under a minute when combined with V-net, a popular three-dimensional semantic-segmentation architecture. High nuclei detection F1-scores of 95.3% and 92.5% were obtained in two different whole quail embryonic hearts, a tissue type difficult to segment because of its high cell density, and heterogeneous and elliptical nuclei. Similar high scores were obtained in the mouse brain stem, demonstrating that this approach is highly transferable to nuclei of different shapes and intensities. Finally, spatial statistics were performed on the resulting centroids. The spatial distribution of nuclei obtained by our approach most resembles the spatial distribution of manually identified nuclei, indicating that this approach could serve in future spatial analyses of cell organization.
- 19 April 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 60396-60408
Open AccessNuclei Detection for 3D Microscopy With a Fully Convolutional Regression Network
Advances in three-dimensional microscopy and tissue clearing are enabling whole-organ imaging with single-cell resolution. Fast and reliable image processing tools are needed to analyze the resulting image volumes, including automated cell detection, cell counting and cell analytics. Deep learning approaches have shown promising results in two- and three-dimensional nuclei detection tasks, however detecting overlapping or non-spherical nuclei of different sizes and shapes in the presence of a blurring point spread function remains challenging and often leads to incorrect nuclei merging and splitting. Here we present a new regression-based fully convolutional network that located a thousand nuclei centroids with high accuracy in under a minute when combined with V-net, a popular three-dimensional semantic-segmentation architecture. High nuclei detection F1-scores of 95.3% and 92.5% were obtained in two different whole quail embryonic hearts, a tissue type difficult to segment because of its high cell density, and heterogeneous and elliptical nuclei. Similar high scores were obtained in the mouse brain stem, demonstrating that this approach is highly transferable to nuclei of different shapes and intensities. Finally, spatial statistics were performed on the resulting centroids. The spatial distribution of nuclei obtained by our approach most resembles the spatial distribution of manually identified nuclei, indicating that this approach could serve in future spatial analyses of cell organization.
- Open Access
- 11 September 2020
- Published by Springer Nature in Scientific Reports
- Vol. 10 (1) , 1-15
Three-dimensional alignment of microvasculature and cardiomyocytes in the developing ventricle
While major coronary artery development and pathologies affecting them have been extensively studied, understanding the development and organization of the coronary microvasculature beyond the earliest developmental stages requires new tools. Without techniques to image the coronary microvasculature over the whole heart, it is likely we are underestimating the microvasculature’s impact on normal development and diseases. We present a new imaging and analysis toolset to visualize the coronary microvasculature in intact embryonic hearts and quantify vessel organization. The fluorescent dyes DiI and DAPI were used to stain the coronary vasculature and cardiomyocyte nuclei in quail embryo hearts during rapid growth and morphogenesis of the left ventricular wall. Vessel and cardiomyocytes orientation were automatically extracted and quantified, and vessel density was calculated. The coronary microvasculature was found to follow the known helical organization of cardiomyocytes in the ventricular wall. Vessel density in the left ventricle did not change during and after compaction. This quantitative and automated approach will enable future cohort studies to understand the microvasculature’s role in diseases such as hypertrophic cardiomyopathy where misalignment of cardiomyocytes has been observed in utero.
- 11 September 2020
- Published by Springer Nature in Scientific Reports
- Vol. 10 (1) , 1-15
Open AccessThree-dimensional alignment of microvasculature and cardiomyocytes in the developing ventricle
While major coronary artery development and pathologies affecting them have been extensively studied, understanding the development and organization of the coronary microvasculature beyond the earliest developmental stages requires new tools. Without techniques to image the coronary microvasculature over the whole heart, it is likely we are underestimating the microvasculature’s impact on normal development and diseases. We present a new imaging and analysis toolset to visualize the coronary microvasculature in intact embryonic hearts and quantify vessel organization. The fluorescent dyes DiI and DAPI were used to stain the coronary vasculature and cardiomyocyte nuclei in quail embryo hearts during rapid growth and morphogenesis of the left ventricular wall. Vessel and cardiomyocytes orientation were automatically extracted and quantified, and vessel density was calculated. The coronary microvasculature was found to follow the known helical organization of cardiomyocytes in the ventricular wall. Vessel density in the left ventricle did not change during and after compaction. This quantitative and automated approach will enable future cohort studies to understand the microvasculature’s role in diseases such as hypertrophic cardiomyopathy where misalignment of cardiomyocytes has been observed in utero.
- 24 February 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 34 (7) , 1549-1561
3-D Stent Detection in Intravascular OCT Using a Bayesian Network and Graph Search
Worldwide, many hundreds of thousands of stents are implanted each year to revascularize occlusions in coronary arteries. Intravascular optical coherence tomography is an important emerging imaging technique, which has the resolution and contrast necessary to quantitatively analyze stent deployment and tissue coverage following stent implantation. Automation is needed, as current, it takes up to 16 h to manually analyze hundreds of images and thousands of stent struts from a single pullback. For automated strut detection, we used image formation physics and machine learning via a Bayesian network, and 3-D knowledge of stent structure via graph search. Graph search was done on en face projections using minimum spanning tree algorithms. Depths of all struts in a pullback were simultaneously determined using graph cut. To assess the method, we employed the largest validation data set used so far, involving more than 8000 clinical images from 103 pullbacks from 72 patients. Automated strut detection achieved a 0.91±0.04 recall, and 0.84±0.08 precision. Performance was robust in images of varying quality. This method can improve the workflow for analysis of stent clinical trial data, and can potentially be used in the clinic to facilitate real-time stent analysis and visualization, aiding stent implantation.
- 24 February 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 34 (7) , 1549-1561
3-D Stent Detection in Intravascular OCT Using a Bayesian Network and Graph Search
Worldwide, many hundreds of thousands of stents are implanted each year to revascularize occlusions in coronary arteries. Intravascular optical coherence tomography is an important emerging imaging technique, which has the resolution and contrast necessary to quantitatively analyze stent deployment and tissue coverage following stent implantation. Automation is needed, as current, it takes up to 16 h to manually analyze hundreds of images and thousands of stent struts from a single pullback. For automated strut detection, we used image formation physics and machine learning via a Bayesian network, and 3-D knowledge of stent structure via graph search. Graph search was done on en face projections using minimum spanning tree algorithms. Depths of all struts in a pullback were simultaneously determined using graph cut. To assess the method, we employed the largest validation data set used so far, involving more than 8000 clinical images from 103 pullbacks from 72 patients. Automated strut detection achieved a 0.91±0.04 recall, and 0.84±0.08 precision. Performance was robust in images of varying quality. This method can improve the workflow for analysis of stent clinical trial data, and can potentially be used in the clinic to facilitate real-time stent analysis and visualization, aiding stent implantation.