Jin-Jie Yu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Jin-Jie Yu has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Chun-Li Lin
Department of Biomedical Engineering, National Yang Ming Chiao Tung University, Taipei, Taiwan
2 shared publications - Yen-Hsiang Chang
Department of General Dentistry, Chang Gung Memorial Hospital, 123, Ding-Hu Road, Kuei-Shan, Tao-Yuan 333, Taiwan
2 shared publications - Wen-Chuan Kuo
Institute of Biophotonics National Yang Ming Chiao Tung University Taipei Taiwan
1 shared publication - Yun-Chu Lin
Department of Biomedical Engineering, National Yang-Ming University, Taipei, Taiwan
1 shared publication
Latest Publications
- Open Access
- 13 December 2014
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 13 (1) , 165
Examination of ceramic restoration adhesive coverage in cusp-replacement premolar using acoustic emission under fatigue testing
This study investigates CAD/CAM ceramic cusp-replacing restoration resistance with and without buccal cusp replacement under static and dynamic cyclic loads, monitored using the acoustic emission (AE) technique. The cavity was designed in a typical MODP (mesial-occlusal-distal-palatal) restoration failure shape when the palatal cusp has been lost. Two ceramic restorations [without coverage (WOC) and with (WC) buccal cuspal coverage with 2.0 mm reduction in cuspal height] were prepared to perform the fracture and fatigue tests with normal (200 N) and high (600 N) occlusal forces. The load versus AE signals in the fracture and fatigue tests were recorded to evaluate the restored tooth failure resistance. The results showed that non-significant differences in load value in the fracture test and the accumulated number of AE signals under normal occlusal force (200 N) in the fatigue test were found between with and without buccal cuspal coverage restorations. The first AE activity occurring for the WOC restoration was lower than that for the WC restoration in the fracture test. The number of AE signals increased with the cyclic load number. The accumulated number of AE signals for the WOC restoration was 187, higher than that (85) for the WC restoration under 600 N in the fatigue test. The AE technique and fatigue tests employed in this study were used as an assessment tool to evaluate the resistances in large CAD/CAM ceramic restorations. Non-significant differences in the tested fracture loads and accumulated number of AE signals under normal occlusal force (200 N) between different restorations indicated that aggressive treatment (with coverage preparation) in palatal cusp-replacing ceramic premolars require more attention for preserving and protecting the remaining tooth.
- 13 December 2014
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 13 (1) , 165
Open AccessExamination of ceramic restoration adhesive coverage in cusp-replacement premolar using acoustic emission under fatigue testing
This study investigates CAD/CAM ceramic cusp-replacing restoration resistance with and without buccal cusp replacement under static and dynamic cyclic loads, monitored using the acoustic emission (AE) technique. The cavity was designed in a typical MODP (mesial-occlusal-distal-palatal) restoration failure shape when the palatal cusp has been lost. Two ceramic restorations [without coverage (WOC) and with (WC) buccal cuspal coverage with 2.0 mm reduction in cuspal height] were prepared to perform the fracture and fatigue tests with normal (200 N) and high (600 N) occlusal forces. The load versus AE signals in the fracture and fatigue tests were recorded to evaluate the restored tooth failure resistance. The results showed that non-significant differences in load value in the fracture test and the accumulated number of AE signals under normal occlusal force (200 N) in the fatigue test were found between with and without buccal cuspal coverage restorations. The first AE activity occurring for the WOC restoration was lower than that for the WC restoration in the fracture test. The number of AE signals increased with the cyclic load number. The accumulated number of AE signals for the WOC restoration was 187, higher than that (85) for the WC restoration under 600 N in the fatigue test. The AE technique and fatigue tests employed in this study were used as an assessment tool to evaluate the resistances in large CAD/CAM ceramic restorations. Non-significant differences in the tested fracture loads and accumulated number of AE signals under normal occlusal force (200 N) between different restorations indicated that aggressive treatment (with coverage preparation) in palatal cusp-replacing ceramic premolars require more attention for preserving and protecting the remaining tooth.
- 1 August 2014
- Published by Elsevier in Dental Materials
- Vol. 30 (8) , 910-916
Examination of ceramic/enamel interfacial debonding using acoustic emission and optical coherence tomography
- 1 August 2014
- Published by Elsevier in Dental Materials
- Vol. 30 (8) , 910-916
Examination of ceramic/enamel interfacial debonding using acoustic emission and optical coherence tomography