Yen-Hsiang Chang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Yen-Hsiang Chang has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Chun-Li Lin
Department of Biomedical Engineering, National Yang Ming Chiao Tung University, Taipei, Taiwan
4 shared publications Chun-Li Lin
2 shared publications- Jin-Jie Yu
Department of Biomedical Engineering, National Yang-Ming University, No.155, Sec.2, Linong Street, Taipei, 112, Taiwan
2 shared publications Yu-Hao Lin
2 shared publications- Chun-Li Lin
Department of Mechanical Engineering, Chang Gung University, Tao-yuan, Taiwan
1 shared publication - Hao Lee
Department of Biomedical Engineering, National Yang-Ming University, No. 155, Sec. 2, Linong Street, Taipei 112, Taiwan
1 shared publication
Latest Publications
- Open Access
- 13 December 2014
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 13 (1) , 165
Examination of ceramic restoration adhesive coverage in cusp-replacement premolar using acoustic emission under fatigue testing
This study investigates CAD/CAM ceramic cusp-replacing restoration resistance with and without buccal cusp replacement under static and dynamic cyclic loads, monitored using the acoustic emission (AE) technique. The cavity was designed in a typical MODP (mesial-occlusal-distal-palatal) restoration failure shape when the palatal cusp has been lost. Two ceramic restorations [without coverage (WOC) and with (WC) buccal cuspal coverage with 2.0 mm reduction in cuspal height] were prepared to perform the fracture and fatigue tests with normal (200 N) and high (600 N) occlusal forces. The load versus AE signals in the fracture and fatigue tests were recorded to evaluate the restored tooth failure resistance. The results showed that non-significant differences in load value in the fracture test and the accumulated number of AE signals under normal occlusal force (200 N) in the fatigue test were found between with and without buccal cuspal coverage restorations. The first AE activity occurring for the WOC restoration was lower than that for the WC restoration in the fracture test. The number of AE signals increased with the cyclic load number. The accumulated number of AE signals for the WOC restoration was 187, higher than that (85) for the WC restoration under 600 N in the fatigue test. The AE technique and fatigue tests employed in this study were used as an assessment tool to evaluate the resistances in large CAD/CAM ceramic restorations. Non-significant differences in the tested fracture loads and accumulated number of AE signals under normal occlusal force (200 N) between different restorations indicated that aggressive treatment (with coverage preparation) in palatal cusp-replacing ceramic premolars require more attention for preserving and protecting the remaining tooth.
- 13 December 2014
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 13 (1) , 165
Open AccessExamination of ceramic restoration adhesive coverage in cusp-replacement premolar using acoustic emission under fatigue testing
This study investigates CAD/CAM ceramic cusp-replacing restoration resistance with and without buccal cusp replacement under static and dynamic cyclic loads, monitored using the acoustic emission (AE) technique. The cavity was designed in a typical MODP (mesial-occlusal-distal-palatal) restoration failure shape when the palatal cusp has been lost. Two ceramic restorations [without coverage (WOC) and with (WC) buccal cuspal coverage with 2.0 mm reduction in cuspal height] were prepared to perform the fracture and fatigue tests with normal (200 N) and high (600 N) occlusal forces. The load versus AE signals in the fracture and fatigue tests were recorded to evaluate the restored tooth failure resistance. The results showed that non-significant differences in load value in the fracture test and the accumulated number of AE signals under normal occlusal force (200 N) in the fatigue test were found between with and without buccal cuspal coverage restorations. The first AE activity occurring for the WOC restoration was lower than that for the WC restoration in the fracture test. The number of AE signals increased with the cyclic load number. The accumulated number of AE signals for the WOC restoration was 187, higher than that (85) for the WC restoration under 600 N in the fatigue test. The AE technique and fatigue tests employed in this study were used as an assessment tool to evaluate the resistances in large CAD/CAM ceramic restorations. Non-significant differences in the tested fracture loads and accumulated number of AE signals under normal occlusal force (200 N) between different restorations indicated that aggressive treatment (with coverage preparation) in palatal cusp-replacing ceramic premolars require more attention for preserving and protecting the remaining tooth.
- 1 August 2014
- Published by Elsevier in Dental Materials
- Vol. 30 (8) , 910-916
Examination of ceramic/enamel interfacial debonding using acoustic emission and optical coherence tomography
- 1 August 2014
- Published by Elsevier in Dental Materials
- Vol. 30 (8) , 910-916
Examination of ceramic/enamel interfacial debonding using acoustic emission and optical coherence tomography
- 11 July 2006
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 44 (8) , 665-673
Buttressing angle of the double-plating fixation of a distal radius fracture: a finite element study
Treatment of a distal radius fracture should consider principles including stable fixation and early motion. The aim of this study was to investigate the biomechanical interactions of plate-fixation angles in the internal double-plating method coupled with various load conditions using non-linear finite element analysis (FEA). A 3D finite element distal radius fracture model with three separation angles (50, 70, and 90 degrees ) between the buttressed L- and straight plates was generated based on computed tomography data. After model verification and validation, frictional (contact) elements were used to simulate the interface condition between the fixation plates and the bony surface. The stress/strain distributions and displacements at the radius end were observed under axial, bending, and torsion load conditions. The simulated results indicated that the bending and torsion increased the stress values more than the axial load. The radius and straight plate stress values decreased significantly with increasing fixation angles for all load conditions. However, the L-plate stress values increased slightly under the bending buckling effect. The displacements at the radius end and strains at the fracture healing interface decreased with increasing fixation angles for axial and torsion conditions but displayed a slight difference for the bending condition. The findings using FEA provide quantitative evidence to identify that much larger plate fixation angles could provide better mechanical strength to establish favorable stress-transmission and prevent distal fragment dislocation.
- 11 July 2006
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 44 (8) , 665-673
Buttressing angle of the double-plating fixation of a distal radius fracture: a finite element study
Treatment of a distal radius fracture should consider principles including stable fixation and early motion. The aim of this study was to investigate the biomechanical interactions of plate-fixation angles in the internal double-plating method coupled with various load conditions using non-linear finite element analysis (FEA). A 3D finite element distal radius fracture model with three separation angles (50, 70, and 90 degrees ) between the buttressed L- and straight plates was generated based on computed tomography data. After model verification and validation, frictional (contact) elements were used to simulate the interface condition between the fixation plates and the bony surface. The stress/strain distributions and displacements at the radius end were observed under axial, bending, and torsion load conditions. The simulated results indicated that the bending and torsion increased the stress values more than the axial load. The radius and straight plate stress values decreased significantly with increasing fixation angles for all load conditions. However, the L-plate stress values increased slightly under the bending buckling effect. The displacements at the radius end and strains at the fracture healing interface decreased with increasing fixation angles for axial and torsion conditions but displayed a slight difference for the bending condition. The findings using FEA provide quantitative evidence to identify that much larger plate fixation angles could provide better mechanical strength to establish favorable stress-transmission and prevent distal fragment dislocation.