Hilary Shanahan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Hilary Shanahan has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Conan McCaul
The Rotunda Hospital, Dublin, Ireland; Mater Misericordiae University Hospital, Dublin, Ireland; University College Dublin, Ireland
1 shared publication - Jonathan Royds
Guys & St. Thomas NHS Foundation Trust, London, UK
1 shared publication - Mark Campbell
Department of Anesthesia, The Rotunda Hospital, Parnell Square, Dublin 1, Ireland
1 shared publication - Simon A. Ash
Department of Anesthesia, The Rotunda Hospital, Parnell Square, Dublin 1, Ireland
1 shared publication - Viera Husarova
Department of Anesthesia, The Rotunda Hospital, Parnell Square, Dublin 1, Ireland
1 shared publication
Latest Publications
- Open Access
- 22 November 2014
- Published by Springer Nature in BMC Anesthesiology
- Vol. 14 (1) , 108
The accuracy of locating the cricothyroid membrane by palpation – an intergender study
The cricothyroid membrane (CTM) is the recommended site of access to the airway during cricothyrotomy to provide emergency oxygenation. We sought to compare the ability of physicians to correctly identify the CTM in male and female patients. In a prospective observational study, anaesthetists were asked to locate the CTM by palpation which was then identified using ultrasound and the distance between the actual and estimated margin of the CTM was measured. Participants assessed the ease of CTM palpation using a visual analog scale. In a second series, the angulation of the posterior junction of the thyroid laminae was measured using ultrasound. 23 anaesthetists and 44 subjects participated. A total of 36 assessments were carried out in each gender. Incorrect identification of the CTM was more common in females (29/36 vs. 11/36, P < 0.001) and the distance from the CTM in the vertical plane was greater (11.0 [6.5–20.0] vs. 0.0 [0.0–10.0] mm, P < 0.001). In females distance from the CTM correlated positively with neck circumference (P = 0.005) and BMI (P = 0.00005) and negatively with subject height (P = 0.01). Posterior thyroid cartilage angulation was greater in females (118.6 ± 9.4° vs. 95.9 ± 12.9°, P = 0.02) and was lower in patients with correctly identified CTMs (100.0 ± 14.9° vs. 115.6 ± 15.9°, P = 0.02). VRS palpation correlated with decreased posterior thyroid cartilage angulation (P = 0.04). CTM localisation is more difficult in female subjects irrespective of body habitus. It may be prudent to localize this structure by additional means (e.g. ultrasound) in advance of any airway manoeuvres or to modify the cricothyrotomy technique in the event that it is necessary in an emergency.
- 22 November 2014
- Published by Springer Nature in BMC Anesthesiology
- Vol. 14 (1) , 108
Open AccessThe accuracy of locating the cricothyroid membrane by palpation – an intergender study
The cricothyroid membrane (CTM) is the recommended site of access to the airway during cricothyrotomy to provide emergency oxygenation. We sought to compare the ability of physicians to correctly identify the CTM in male and female patients. In a prospective observational study, anaesthetists were asked to locate the CTM by palpation which was then identified using ultrasound and the distance between the actual and estimated margin of the CTM was measured. Participants assessed the ease of CTM palpation using a visual analog scale. In a second series, the angulation of the posterior junction of the thyroid laminae was measured using ultrasound. 23 anaesthetists and 44 subjects participated. A total of 36 assessments were carried out in each gender. Incorrect identification of the CTM was more common in females (29/36 vs. 11/36, P < 0.001) and the distance from the CTM in the vertical plane was greater (11.0 [6.5–20.0] vs. 0.0 [0.0–10.0] mm, P < 0.001). In females distance from the CTM correlated positively with neck circumference (P = 0.005) and BMI (P = 0.00005) and negatively with subject height (P = 0.01). Posterior thyroid cartilage angulation was greater in females (118.6 ± 9.4° vs. 95.9 ± 12.9°, P = 0.02) and was lower in patients with correctly identified CTMs (100.0 ± 14.9° vs. 115.6 ± 15.9°, P = 0.02). VRS palpation correlated with decreased posterior thyroid cartilage angulation (P = 0.04). CTM localisation is more difficult in female subjects irrespective of body habitus. It may be prudent to localize this structure by additional means (e.g. ultrasound) in advance of any airway manoeuvres or to modify the cricothyrotomy technique in the event that it is necessary in an emergency.