Gregg Chapman
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Gregg Chapman has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Aditya Nechiyil
Department of Electrical and Computer Engineering, The Ohio State University, Columbus, USA
2 shared publications - Douglas A MurreyJr
Division of Molecular Imaging and Nuclear Medicine, Department of Radiology, The Ohio State University Wexner Medical Center, Columbus, OH 43210, USA
2 shared publications - Edward W MartinJr
Division of Surgical Oncology, Department of Surgery, Arthur G. James Cancer Hospital and Richard J. Solove Research Institute and Comprehensive Cancer Center, The Ohio State University Wexner Medical Center, Columbus, OH 43210, USA
2 shared publications - Nathan C. Hall
Department of Educational and Counselling Psychology, McGill University, Montréal, Canada
2 shared publications - Robert Lee
Department of Electrical and Computer Engineering, The Ohio State University, Columbus, OH 43210, USA
2 shared publications - Robert Lee
Department of Electrical and Computer Engineering ElectroScience Laboratory The Ohio State University 43212-1166 Columbus OH USA
2 shared publications
Latest Publications
- Open Access
- 8 August 2024
- Published by Springer Nature in Journal of Failure Analysis and Prevention
- Vol. 24 (5) , 2105-2112
Classification and Novelty Detection of Tampered ICs Using ResCav
This paper investigates the capabilities of the resonant cavity system (ResCav) for detecting tampered integrated circuits (ICs) within supply chains. Prior research showcased ResCav’s ability to discern minor circuit variations, this study focuses on enhancing supervised classification results and introduces a one-class support vector machine (SVM) approach with a modified radial basis function kernel for novelty detection. Through finer hyperparameter tuning, the system achieves improved classification accuracy, demonstrating its potential to identify nuanced alterations with even higher precision and recall rates. Additionally, the application of a one-class SVM enables the detection of tampered ICs without reliance on labeled datasets, expanding utility in scenarios where access is limited to golden ICs. These advancements in ResCav’s capabilities signify progress in failure prevention methodologies, offering an efficient and non-destructive solution crucial for safeguarding against counterfeit and non-conforming components infiltrating critical supply chains.
- 8 August 2024
- Published by Springer Nature in Journal of Failure Analysis and Prevention
- Vol. 24 (5) , 2105-2112
Open AccessClassification and Novelty Detection of Tampered ICs Using ResCav
This paper investigates the capabilities of the resonant cavity system (ResCav) for detecting tampered integrated circuits (ICs) within supply chains. Prior research showcased ResCav’s ability to discern minor circuit variations, this study focuses on enhancing supervised classification results and introduces a one-class support vector machine (SVM) approach with a modified radial basis function kernel for novelty detection. Through finer hyperparameter tuning, the system achieves improved classification accuracy, demonstrating its potential to identify nuanced alterations with even higher precision and recall rates. Additionally, the application of a one-class SVM enables the detection of tampered ICs without reliance on labeled datasets, expanding utility in scenarios where access is limited to golden ICs. These advancements in ResCav’s capabilities signify progress in failure prevention methodologies, offering an efficient and non-destructive solution crucial for safeguarding against counterfeit and non-conforming components infiltrating critical supply chains.
- Open Access
- 7 July 2024
- Published by MDPI AG in Instruments
- Vol. 8 (3) , 37
A Rapid, Non-Destructive Method to Detect Counterfeit Integrated Circuits Using a Resonant Cavity System
The counterfeiting of integrated circuits (ICs) has been a growing issue. Current available methods used to detect counterfeit ICs can be expensive, imprecise, and time-consuming. This paper explores the resonant cavity system: a non-contact, non-destructive method to rapidly differentiate counterfeit ICs from authentic ones. The system captures a unique signature of an IC placed inside it. Data were captured for ICs of various technologies and authenticities. The data included return loss values captured at various transverse electric (TE) modes between 2.8 GHz and 6 GHz. This allowed for the comparison of the effectiveness of the various TE modes in being able to distinguish ICs. The resonant cavity system was able to distinguish most of the ICs at higher TE modes.
- 7 July 2024
- Published by MDPI AG in Instruments
- Vol. 8 (3) , 37
Open AccessA Rapid, Non-Destructive Method to Detect Counterfeit Integrated Circuits Using a Resonant Cavity System
The counterfeiting of integrated circuits (ICs) has been a growing issue. Current available methods used to detect counterfeit ICs can be expensive, imprecise, and time-consuming. This paper explores the resonant cavity system: a non-contact, non-destructive method to rapidly differentiate counterfeit ICs from authentic ones. The system captures a unique signature of an IC placed inside it. Data were captured for ICs of various technologies and authenticities. The data included return loss values captured at various transverse electric (TE) modes between 2.8 GHz and 6 GHz. This allowed for the comparison of the effectiveness of the various TE modes in being able to distinguish ICs. The resonant cavity system was able to distinguish most of the ICs at higher TE modes.
- Open Access
- 13 September 2014
- Published by Springer Nature in BMC Cancer
- Vol. 14 (1) , 667
Comparison of two threshold detection criteria methodologies for determination of probe positivity for intraoperative in situ identification of presumed abnormal 18F-FDG-avid tissue sites during radioguided oncologic surgery
Intraoperative in situ identification of 18F-FDG-avid tissue sites during radioguided oncologic surgery remains a significant challenge for surgeons. The purpose of our study was to evaluate the 1.5-to-1 ratiometric threshold criteria method versus the three-sigma statistical threshold criteria method for determination of gamma detection probe positivity for intraoperative in situ identification of presumed abnormal 18F-FDG-avid tissue sites in a manner that was independent of the specific type of gamma detection probe used. From among 52 patients undergoing appropriate in situ evaluation of presumed abnormal 18F-FDG-avid tissue sites during 18F-FDG-directed surgery using 6 available gamma detection probe systems, a total of 401 intraoperative gamma detection probe measurement sets of in situ counts per second measurements were cumulatively taken. For the 401 intraoperative gamma detection probe measurement sets, probe positivity was successfully met by the 1.5-to-1 ratiometric threshold criteria method in 150/401 instances (37.4%) and by the three-sigma statistical threshold criteria method in 259/401 instances (64.6%) (P < 0.001). Likewise, the three-sigma statistical threshold criteria method detected true positive results at target-to-background ratios much lower than the 1.5-to-1 target-to-background ratio of the 1.5-to-1 ratiometric threshold criteria method. The three-sigma statistical threshold criteria method was significantly better than the 1.5-to-1 ratiometric threshold criteria method for determination of gamma detection probe positivity for intraoperative in situ detection of presumed abnormal 18F-FDG-avid tissue sites during radioguided oncologic surgery. This finding may be extremely important for reshaping the ongoing and future research and development of gamma detection probe systems that are necessary for optimizing the in situ detection of radioisotopes of higher-energy gamma photon emissions used during radioguided oncologic surgery.
- 13 September 2014
- Published by Springer Nature in BMC Cancer
- Vol. 14 (1) , 667
Open AccessComparison of two threshold detection criteria methodologies for determination of probe positivity for intraoperative in situ identification of presumed abnormal 18F-FDG-avid tissue sites during radioguided oncologic surgery
Intraoperative in situ identification of 18F-FDG-avid tissue sites during radioguided oncologic surgery remains a significant challenge for surgeons. The purpose of our study was to evaluate the 1.5-to-1 ratiometric threshold criteria method versus the three-sigma statistical threshold criteria method for determination of gamma detection probe positivity for intraoperative in situ identification of presumed abnormal 18F-FDG-avid tissue sites in a manner that was independent of the specific type of gamma detection probe used. From among 52 patients undergoing appropriate in situ evaluation of presumed abnormal 18F-FDG-avid tissue sites during 18F-FDG-directed surgery using 6 available gamma detection probe systems, a total of 401 intraoperative gamma detection probe measurement sets of in situ counts per second measurements were cumulatively taken. For the 401 intraoperative gamma detection probe measurement sets, probe positivity was successfully met by the 1.5-to-1 ratiometric threshold criteria method in 150/401 instances (37.4%) and by the three-sigma statistical threshold criteria method in 259/401 instances (64.6%) (P < 0.001). Likewise, the three-sigma statistical threshold criteria method detected true positive results at target-to-background ratios much lower than the 1.5-to-1 target-to-background ratio of the 1.5-to-1 ratiometric threshold criteria method. The three-sigma statistical threshold criteria method was significantly better than the 1.5-to-1 ratiometric threshold criteria method for determination of gamma detection probe positivity for intraoperative in situ detection of presumed abnormal 18F-FDG-avid tissue sites during radioguided oncologic surgery. This finding may be extremely important for reshaping the ongoing and future research and development of gamma detection probe systems that are necessary for optimizing the in situ detection of radioisotopes of higher-energy gamma photon emissions used during radioguided oncologic surgery.
- Open Access
- 4 March 2013
- Published by Springer Nature in BMC Cancer
- Vol. 13 (1) , 98
Intraoperative detection of 18F-FDG-avid tissue sites using the increased probe counting efficiency of the K-alpha probe design and variance-based statistical analysis with the three-sigma criteria
Intraoperative detection of 18F-FDG-avid tissue sites during 18F-FDG-directed surgery can be very challenging when utilizing gamma detection probes that rely on a fixed target-to-background (T/B) ratio (ratiometric threshold) for determination of probe positivity. The purpose of our study was to evaluate the counting efficiency and the success rate of in situ intraoperative detection of 18F-FDG-avid tissue sites (using the three-sigma statistical threshold criteria method and the ratiometric threshold criteria method) for three different gamma detection probe systems.
- 4 March 2013
- Published by Springer Nature in BMC Cancer
- Vol. 13 (1) , 98
Open AccessIntraoperative detection of 18F-FDG-avid tissue sites using the increased probe counting efficiency of the K-alpha probe design and variance-based statistical analysis with the three-sigma criteria
Intraoperative detection of 18F-FDG-avid tissue sites during 18F-FDG-directed surgery can be very challenging when utilizing gamma detection probes that rely on a fixed target-to-background (T/B) ratio (ratiometric threshold) for determination of probe positivity. The purpose of our study was to evaluate the counting efficiency and the success rate of in situ intraoperative detection of 18F-FDG-avid tissue sites (using the three-sigma statistical threshold criteria method and the ratiometric threshold criteria method) for three different gamma detection probe systems.