RSRyuichi Shinjo

Ryuichi Shinjo

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Ryuichi Shinjo has a total of 34 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Factors associated with favorable outcomes of floating fusion or lumbosacral spinal fusion in adult spinal deformity surgery: an analysis of the incidence of mechanical complications from a multicenter study

    by Yujiro Kagami, Hiroaki Nakashima, Naoki Segi, Sadayuki Ito, Jun Ouchida, Ippei Yamauchi, Yukihito Ode, Yasuhiro Nagatani, Yuya Okada, Yosuke Takeichi, et al.

    Purpose Lumbosacral fusion (LSF) is the standard approach in adult spinal deformity (ASD) surgery but is frequently associated with proximal junctional kyphosis. Floating fusion (FF) has been proposed as an alternative approach. This study examined factors influencing the selection of FF and identified postoperative adverse factors associated with each surgical approach. Methods This multicenter study retrospectively reviewed the records of patients who underwent surgery for ASD. They were divided into FF and LSF groups and compared by baseline patient characteristics and radiological parameters. Each group was further divided and compared according to mechanical complications (MC). Results The number of fusion levels (odds ratio [OR] = 0.50, 95% confidence interval [CI]: 0.41–0.61, P < 0.01), thoracic kyphosis (OR = 1.03, 95% CI: 1.00–1.06, P = 0.045), and lower lumbar lordosis (LL) (OR = 1.07, 95% CI: 1.03–1.10, P < 0.01) were independently associated with FF. In FF, the correction amounts for LL and PI − LL were lower in the MC subgroup (LL: no MC, 9.3 ± 12.5; MC, 2.1 ± 16.1, P = 0.04 and PI – LL: no MC, − 10.6 ± 12.3; MC, − 2.1 ± 14.1, P = 0.02). In LSF, the preoperative SVA was higher in the MC subgroup (no MC, 82.5 ± 55.4; MC, 103.1 ± 46.7; P = 0.049). Conclusion FF outcomes were more favorable in patients undergoing short-segment fusion who retained TK or lower lumbar lordosis. Various procedural demands influenced postoperative MC: FF requires LL proportional to the PI, whereas LSF focuses on global alignment correction.

  • Open Access

    Preoperative Low Lumbar Hounsfield Units and Global Alignment Predict Postoperative Mechanical Complications After Adult Spinal Deformity Surgery: A Multicenter Retrospective Study

    by Ippei Yamauchi, Hiroaki Nakashima, Sadayuki Ito, Naoki Segi, Jun Ouchida, Yoshinori Morita, Yukihito Ode, Yasuhiro Nagatani, Yuya Okada, Yosuke Takeichi, et al.

    Objectives: This study investigated the potential of Hounsfield unit (HU) values obtained from computed tomography (CT) scans as predictors of mechanical complications (MCs) in patients undergoing long-segment spinal fusion involving the pelvis. Additionally, it identified a threshold HU value associated with an increased risk of MCs. Methods: We conducted a retrospective, multicenter review of patients who underwent long-segment spinal fusion involving the pelvis, with a minimum follow-up period of two years. Patients were categorized based on the presence or absence of postoperative MCs. Both preoperative and postoperative radiographic parameters were analyzed, and HU values were quantified from CT images. Logistic regression modeling was used to identify independent risk factors for MCs. Results: Among 129 patients, 33 (25.6%) developed MCs, including proximal and distal junctional failures, rod fractures, and cases necessitating re-operation. The HU values were significantly lower in the MC group, whereas conventional bone mineral density (BMD) measurements showed no significant difference. Global alignment parameters, such as the sagittal vertical axis (SVA) and global tilt (GT), were consistently higher in patients with MCs. Receiver operating characteristic analysis identified 131 HU as the optimal cut-off, yielding a sensitivity of 56.4% and a specificity of 69.7%. Multivariate analysis confirmed that lower HU values were independently associated with the occurrence of MCs. Conclusions: Lower HU values and larger radiological global alignment parameters are significant predictors of MCs in patients undergoing surgery for adult spinal deformity. These findings underscore the importance of CT-based quantitative assessments in preoperative planning.


  • Comparative analysis of single-stage versus two-stage fusion surgeries for adult spinal deformity: radiographic outcomes, clinical improvements, and complication rates

    by Jun Ouchida, Hiroaki Nakashima, Sadayuki Ito, Naoki Segi, Ippei Yamauchi, Yoshinori Morita, Tokumi Kanemura, Tetsuya Ohara, Taichi Tsuji, Ryuichi Shinjo, et al.

    Purpose To compare single-stage and two-stage corrective fusion surgeries for adult spinal deformity (ASD), focusing on radiographic and clinical outcomes, and surgery-related complications. Methods A retrospective cohort study of 245 ASD patients who underwent spinal fusion surgery involving three or more vertebral levels was conducted. Patients were categorized into single-stage and two-stage groups. Propensity score matching was performed to adjust for age, surgical procedure, and radiographical parameters. Radiographic parameters, complication rates, and the Japanese Orthopaedics Association (JOA) score were compared Results After matching for clinical background, the two-stage group showed longer surgery times (493.7 ± 157.2 min vs. 271.3 ± 125.7 min, p < 0.001) and greater estimated blood loss (1617.1 ± 1276.9 mL vs. 1067.5 ± 1274.0 mL, p < 0.001). Surgery-related complication rates were similar between the two groups (20.0% vs. 20.0%, p = 1.000). At two years post-surgery, the two-stage group demonstrated significantly superior JOA score improvement (100.9 ± 84.5% vs. 68.2 ± 62.6%, p = 0.017), lower pelvic tilt (23.6 ± 11.3° vs. 29.1 ± 14.7°, p = 0.023) and a trend towards smaller sagittal vertical axis (40.6 ± 42.7 mm vs. 58.9 ± 58.7 mm, p = 0.075). Conclusions Comparative analysis with matched clinical backgrounds revealed that the two-stage approach maintained equivalent complication rates while achieving sufficient correction effects and favorable clinical score improvements at two years post-surgery. To elucidate the relationship between individual surgical strategies and personalized complication risks, further research is necessary.

  • Open Access

    Vertebral Endplate Concavity in Lateral Lumbar Interbody Fusion: Tapered 3D-Printed Porous Titanium Cage versus Squared PEEK Cage

    by Naoki Segi, Hiroaki Nakashima, Ryuichi Shinjo, Yujiro Kagami, Masaaki Machino, Sadayuki Ito, Jun Ouchida, Kazuaki Morishita, Ryotaro Oishi, Ippei Yamauchi, et al.

    Background and Objectives: To prevent postoperative problems in extreme lateral interbody fusion (XLIF), it is critical that the vertebral endplate not be injured. Unintentional endplate injuries may depend on the cage. A novel porous titanium cage for XLIF has improved geometry with a tapered tip and smooth surface. We hypothesized that this new cage should lead to fewer endplate injuries. Materials and Methods: This retrospective study included 32 patients (mean 74.1 ± 6.7 years, 22 females) who underwent anterior and posterior combined surgery with XLIF for lumbar degenerative disease or adult spinal deformity from January 2018 to June 2022. A tapered 3D porous titanium cage (3DTi; 11 patients) and a squared PEEK cage (sPEEK; 21 patients) were used. Spinal alignment values were measured on X-ray images. Vertebral endplate concavity (VEC) was defined as concavity ≥ 1 mm of the endplate on computed tomography (CT) images, which were evaluated preoperatively and at 1 week and 3 months postoperatively. Results: There were no significant differences in the patient demographic data and preoperative and 3-month postoperative spinal alignments between the groups. A 3DTi was used for 25 levels and an sPEEK was used for 38 levels. Preoperative local lordotic angles were 4.3° for 3DTi vs. 4.7° for sPEEK (p = 0.90), which were corrected to 12.3° and 9.1° (p = 0.029), respectively. At 3 months postoperatively, the angles were 11.6° for 3DTi and 8.2° for sPEEK (p = 0.013). VEC was present in 2 levels (8.0%) for 3DTi vs. 17 levels (45%) for sPEEK (p = 0.002). After 3 months postoperatively, none of the 3DTi had VEC progression; however, eight (21%) levels in sPEEK showed VEC progression (p = 0.019). Conclusions: The novel 3DTi cage reduced endplate injuries by reducing the endplate load during cage insertion.


  • Open Access

    Unilateral instrumented fixation for cervical dumbbell tumors

    by Kei Ando, Shiro Imagama, Zenya Ito, Kazuyoshi Kobayashi, Junichi Ukai, Akio Muramoto, Ryuichi Shinjo, Tomohiro Matsumoto, Hiroaki Nakashima, Yoshihiro Nishida, et al.

    The purpose of this study was to describe the radiological outcomes in patients with unilateral instrumented fixation for cervical dumbbell tumors. Fourteen consecutive individuals were included in the present study. We included Eden type II and III tumors in this cohort study and analyzed fixed segment fusion rates, screw failure with multiplanar reconstruction computed tomography (CT) scan radiographs and lateral radiographs with flexion-extension dynamic views, and immediate postoperative and last follow-up radiographs after surgery. The mean follow-up was 105.4 months. There were six men and eight women ranging in age from 32 to 70 years (mean age, 48 years). Twenty pedicle screws (PSs) and 11 lateral mass screws (LMSs) were used in total. There were seven patients with only PSs, four with only LMSs, and three with PSs at C2 and LMSs at C3. PS misplacement occurred in three screws of insertions including two screws with grade 1 misplacement and one screw with grade 2 misplacement, and no grade 3 misplacement occurred. All screws breached the lateral wall with no apparent superior or inferior misplacement. None of the LMSs were misplaced. Fortunately, no complication could be directly attributed to screw insertion. Radiological evidence showed that all patients achieved successful fusion with no screw loosening or breakage. However, two patients who received only LMS fixation had degenerative spondylolisthesis at the upper fusion segment at the last follow-up. Grade 2 PS misplacement occurred in one screw of insertions. Unilateral pedicle screw fixation for cervical dumbbell tumors is a useful surgical method that can successfully fuse vertebrae with good postoperative alignment.