Chao Zhuang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Chao Zhuang has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Genki Yoshikawa
Research Center for Macromolecules and Biomaterials, National Institute for Materials Science, 1-1 Namiki, Tsukuba, Ibaraki 305-0044, Japan
4 shared publications - Kosuke Minami
Research Center for Macromolecules and Biomaterials, National Institute for Materials Science, 1-1 Namiki, Tsukuba, Ibaraki 305-0044, Japan
4 shared publications - Kota Shiba
Research Center for Macromolecules and Biomaterials (RCMB) National Institute for Materials Science (NIMS) Tsukuba Ibaraki Japan
4 shared publications - Aephraim M. Steinberg
University of Toronto
1 shared publication - Chen Gu
Teaching Center of Experimental Physics, Tsinghua University, Beijing, China
1 shared publication - David A. Weitz
John A. Paulson School of Engineering and Applied Sciences Harvard University Cambridge Massachusetts USA
1 shared publication
Latest Publications
- 1 January 2024
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 63 (1) , 015005
Tailoring stresses in piezoresistive microcantilevers for enhanced surface stress sensing: insights from topology optimization
In assessing piezoresistive microcantilever sensitivity for surface stress sensing, the key is its capacity to translate surface stress into changes in resistance. This change hinges on the interplay between stresses and piezoresistivity. Traditional optimization has been constrained by rudimentary 1D models, overlooking potentially superior designs. Addressing this, we employed topology optimization to optimize Si(100) microcantilevers with a p-type piezoresistor. This led to optimized designs with up to 30% enhanced sensitivity over conventional designs. A recurrent “double-cantilever” configuration emerged, which optimizes longitudinal stress and reduces transverse stress at the piezoresistor, resulting in enhanced sensitivity. We developed a simplified model to analyze stress distributions in these designs. By adjusting geometrical features in this model, we identified ideal parameter combinations for optimal stress distribution. Contrary to conventional designs favoring short cantilevers, our findings redefine efficient surface stress sensing, paving the way for innovative sensor designs beyond the conventional rectangular cantilevers.
- 1 January 2024
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 63 (1) , 015005
Tailoring stresses in piezoresistive microcantilevers for enhanced surface stress sensing: insights from topology optimization
In assessing piezoresistive microcantilever sensitivity for surface stress sensing, the key is its capacity to translate surface stress into changes in resistance. This change hinges on the interplay between stresses and piezoresistivity. Traditional optimization has been constrained by rudimentary 1D models, overlooking potentially superior designs. Addressing this, we employed topology optimization to optimize Si(100) microcantilevers with a p-type piezoresistor. This led to optimized designs with up to 30% enhanced sensitivity over conventional designs. A recurrent “double-cantilever” configuration emerged, which optimizes longitudinal stress and reduces transverse stress at the piezoresistor, resulting in enhanced sensitivity. We developed a simplified model to analyze stress distributions in these designs. By adjusting geometrical features in this model, we identified ideal parameter combinations for optimal stress distribution. Contrary to conventional designs favoring short cantilevers, our findings redefine efficient surface stress sensing, paving the way for innovative sensor designs beyond the conventional rectangular cantilevers.
- Open Access
- 11 August 2023
- Published by IOP Publishing in Nano Express
- Vol. 4 (3) , 035007
Topology optimization for piezoresistive nanomechanical surface stress sensors in anisotropic 〈111〉 orientations
Microelectromechanical systems (MEMS)-based piezoresistive nanomechanical sensors are compact sensing platforms widely employed in vapor sensing, environmental monitoring, and biosensing. Despite their extensive utility, their lower sensitivity relative to their optical readout counterparts has been a limiting factor, constraining the wider application of this technology. Prior research has suggested that alternative silicon orientations, such as 〈111〉 orientations in (110) wafers, can significantly improve the sensitivity of piezoresistive sensors. However, the complexity of optimizing two-dimensional stress distribution and handling anisotropic elasticity has made device design a formidable task, leaving this promising avenue largely unexplored. To address this challenge, we employ density-based topology optimization to generate a series of optimized designs for piezoresistive nanomechanical sensors manufactured along 〈111〉 orientations. The properties of the immobilization layer—the functional coating on the sensor—are parametrically varied to explore optimal designs. Our study reveals a transition in optimized designs from a double-cantilever configuration to a suspended platform configuration, dictated by the stiffness ratio between the immobilization layer and the silicon layer. This transition is attributed to the shift in the neutral plane and the prevailing stress relaxation mechanism. In addition, we scrutinize the effects of piezoresistor geometry and find that the optimized designs depend asymmetrically on the piezoresistor position, a characteristic stemming from the anisotropic elasticity in 〈111〉 orientations. These optimized designs, verified by finite element analysis (FEA), demonstrate a notable improvement in sensitivity of more than 20% when benchmarked against traditional rectangular designs and equivalent optimized designs in conventional orientations, thereby validating the effectiveness of the present model. This study provides crucial knowledge for the design of piezoresistive biosensors, facilitating more efficient geometric design in future sensor development.
- 11 August 2023
- Published by IOP Publishing in Nano Express
- Vol. 4 (3) , 035007
Open AccessTopology optimization for piezoresistive nanomechanical surface stress sensors in anisotropic 〈111〉 orientations
Microelectromechanical systems (MEMS)-based piezoresistive nanomechanical sensors are compact sensing platforms widely employed in vapor sensing, environmental monitoring, and biosensing. Despite their extensive utility, their lower sensitivity relative to their optical readout counterparts has been a limiting factor, constraining the wider application of this technology. Prior research has suggested that alternative silicon orientations, such as 〈111〉 orientations in (110) wafers, can significantly improve the sensitivity of piezoresistive sensors. However, the complexity of optimizing two-dimensional stress distribution and handling anisotropic elasticity has made device design a formidable task, leaving this promising avenue largely unexplored. To address this challenge, we employ density-based topology optimization to generate a series of optimized designs for piezoresistive nanomechanical sensors manufactured along 〈111〉 orientations. The properties of the immobilization layer—the functional coating on the sensor—are parametrically varied to explore optimal designs. Our study reveals a transition in optimized designs from a double-cantilever configuration to a suspended platform configuration, dictated by the stiffness ratio between the immobilization layer and the silicon layer. This transition is attributed to the shift in the neutral plane and the prevailing stress relaxation mechanism. In addition, we scrutinize the effects of piezoresistor geometry and find that the optimized designs depend asymmetrically on the piezoresistor position, a characteristic stemming from the anisotropic elasticity in 〈111〉 orientations. These optimized designs, verified by finite element analysis (FEA), demonstrate a notable improvement in sensitivity of more than 20% when benchmarked against traditional rectangular designs and equivalent optimized designs in conventional orientations, thereby validating the effectiveness of the present model. This study provides crucial knowledge for the design of piezoresistive biosensors, facilitating more efficient geometric design in future sensor development.
- 21 March 2023
- Published by American Chemical Society (ACS) in ACS Applied Engineering Materials
- Vol. 1 (4) , 1213-1219
Linear Stiffness Tuning in MEMS Devices via Prestress Introduced by TiN Thin Films
- 21 March 2023
- Published by American Chemical Society (ACS) in ACS Applied Engineering Materials
- Vol. 1 (4) , 1213-1219
Linear Stiffness Tuning in MEMS Devices via Prestress Introduced by TiN Thin Films
- Open Access
- 17 November 2022
- Published by Wiley in Advanced Science
- Vol. 10 (1)
Visualization of Flow‐Induced Strain Using Structural Color in Channel‐Free Polydimethylsiloxane Devices
Measuring flow of gases is of fundamental importance yet is typically done with complex equipment. There is, therefore, a longstanding need for a simple and inexpensive means of flow measurement. Here, gas flow is measured using an extremely simple device that consists of an Ar plasma‐treated polydimethylsiloxane (PDMS) slab adhered on a glass substrate with a tight seal. This device does not even have a channel, instead, gas can flow between the PDMS and the glass by deforming the PDMS wall, in other words, by making an interstice as a temporary path for the flow. The formation of the temporary path results in a compressive bending stress at the inner wall of the path, which leads to the formation of well‐ordered wrinkles, and hence, the emergence of structural color that changes the optical transmittance of the device. Although it is very simple, this setup works sufficiently well to measure arbitrary gases and analyzes their flow rates, densities, and viscosities based on the change in color. It is also demonstrated that this technique is applicable to the flow‐induced display of a pattern such as a logo for advanced applications.
- 17 November 2022
- Published by Wiley in Advanced Science
- Vol. 10 (1)
Open AccessVisualization of Flow‐Induced Strain Using Structural Color in Channel‐Free Polydimethylsiloxane Devices
Measuring flow of gases is of fundamental importance yet is typically done with complex equipment. There is, therefore, a longstanding need for a simple and inexpensive means of flow measurement. Here, gas flow is measured using an extremely simple device that consists of an Ar plasma‐treated polydimethylsiloxane (PDMS) slab adhered on a glass substrate with a tight seal. This device does not even have a channel, instead, gas can flow between the PDMS and the glass by deforming the PDMS wall, in other words, by making an interstice as a temporary path for the flow. The formation of the temporary path results in a compressive bending stress at the inner wall of the path, which leads to the formation of well‐ordered wrinkles, and hence, the emergence of structural color that changes the optical transmittance of the device. Although it is very simple, this setup works sufficiently well to measure arbitrary gases and analyzes their flow rates, densities, and viscosities based on the change in color. It is also demonstrated that this technique is applicable to the flow‐induced display of a pattern such as a logo for advanced applications.
- Open Access
Plasmonic Sensing Characteristics of Gold Nanorods with Large Aspect Ratios
Plasmonic gold nanorods play important roles in nowadays state-of-the-art plasmonic sensing techniques. Most of the previous studies and applications focused on gold nanorods with relatively small aspect ratios, where the plasmon wavelengths are smaller than 900 nm. Gold nanorods with large aspect ratios are predicted to exhibit high refractive-index sensitivity (Langmir 2008, 24, 5233–5237), which therefore should be promising for the development of high-performance plasmonic chemical- and bio-sensors. In this study, we developed gold nanorods with aspect ratios over 7.9, which exhibit plasmon resonances around 1064 nm. The refractive index (RI) sensitivity of these nanorods have been evaluated by varying their dielectric environment, whereby a sensitivity as high as 473 nm/RIU (refractive index unit) can be obtained. Furthermore, we have demonstrated the large-aspect-ratio nanorods as efficient substrate for surface enhanced Raman spectroscopy (SERS), where an enhancement factor (EF) as high as 9.47 × 108 was measured using 4-methylbenzenethiol (4-MBT) as probe molecule. Finally, a type of flexible SERS substrate is developed by conjugating the gold nanorods with the polystyrene (PS) polymer. The results obtained in our study can benefit the development of plasmonic sensing techniques utilized in the near-infrared spectral region.
Open AccessPlasmonic Sensing Characteristics of Gold Nanorods with Large Aspect Ratios
Plasmonic gold nanorods play important roles in nowadays state-of-the-art plasmonic sensing techniques. Most of the previous studies and applications focused on gold nanorods with relatively small aspect ratios, where the plasmon wavelengths are smaller than 900 nm. Gold nanorods with large aspect ratios are predicted to exhibit high refractive-index sensitivity (Langmir 2008, 24, 5233–5237), which therefore should be promising for the development of high-performance plasmonic chemical- and bio-sensors. In this study, we developed gold nanorods with aspect ratios over 7.9, which exhibit plasmon resonances around 1064 nm. The refractive index (RI) sensitivity of these nanorods have been evaluated by varying their dielectric environment, whereby a sensitivity as high as 473 nm/RIU (refractive index unit) can be obtained. Furthermore, we have demonstrated the large-aspect-ratio nanorods as efficient substrate for surface enhanced Raman spectroscopy (SERS), where an enhancement factor (EF) as high as 9.47 × 108 was measured using 4-methylbenzenethiol (4-MBT) as probe molecule. Finally, a type of flexible SERS substrate is developed by conjugating the gold nanorods with the polystyrene (PS) polymer. The results obtained in our study can benefit the development of plasmonic sensing techniques utilized in the near-infrared spectral region.
- Open Access
- 5 February 2008
- Published by American Physical Society (APS) in Physical Review A
- Vol. 77 (2) , 022303
Efficient vibrational state coupling in an optical tilted-washboard potential via multiple spatial translations and application to pulse echoes
We measure the application of simple and compound pulses consisting of time-dependent spatial translations to coupling vibrational states of ultracold atoms in a far-detuned 1D optical lattice. The lattice wells are so shallow as to support only two bound states, and we prepare the atoms in the ground state. The lattice is oriented vertically, leading to a tilted-washboard potential analogous to those encountered in condensed-matter systems. Experimentally, we find that a square pulse consisting of lattice displacements and a delay is more efficient than single-step pulses or Gaussian pulses. This is described as an example of coherent control. It is striking that contrary to the intuition that soft pulses minimize loss, the Gaussian pulse is outperformed by the square pulse. Numerical calculations are in strong agreement with our experimental results and show the superiority of the square pulse to the single-step pulse for all lattice depths and to the Gaussian pulse for lattice depths greater than seven lattice recoil energies. We also compare the effectiveness of these pulses for reviving oscillations of atoms in vibrational superposition states using the pulse-echo technique. We find that the square and Gaussian pulses result in higher echo amplitudes than the single-step pulse. These improved echo pulses allow us to probe coherence at longer times than in the past, measuring a plateau which has yet to be explained. In addition, we show numerically that the vibrational state coupling due to such lattice manipulations is more efficient in shallow lattices than in deep lattices. The coupling probability for an optimized single-step pulse approaches as the depth goes to infinity (harmonic-oscillator limit), while in shallow lattices with large anharmonicity, the coupling probability reaches a maximum value of 0.51 for a lattice depth of five recoil energies. For square and Gaussian pulses the coupling in the lattice is even stronger, reaching maxima of 0.64 at 6 recoil energies and 0.67 at 5 recoil energies, respectively.- 5 February 2008
- Published by American Physical Society (APS) in Physical Review A
- Vol. 77 (2) , 022303
Open AccessEfficient vibrational state coupling in an optical tilted-washboard potential via multiple spatial translations and application to pulse echoes
We measure the application of simple and compound pulses consisting of time-dependent spatial translations to coupling vibrational states of ultracold atoms in a far-detuned 1D optical lattice. The lattice wells are so shallow as to support only two bound states, and we prepare the atoms in the ground state. The lattice is oriented vertically, leading to a tilted-washboard potential analogous to those encountered in condensed-matter systems. Experimentally, we find that a square pulse consisting of lattice displacements and a delay is more efficient than single-step pulses or Gaussian pulses. This is described as an example of coherent control. It is striking that contrary to the intuition that soft pulses minimize loss, the Gaussian pulse is outperformed by the square pulse. Numerical calculations are in strong agreement with our experimental results and show the superiority of the square pulse to the single-step pulse for all lattice depths and to the Gaussian pulse for lattice depths greater than seven lattice recoil energies. We also compare the effectiveness of these pulses for reviving oscillations of atoms in vibrational superposition states using the pulse-echo technique. We find that the square and Gaussian pulses result in higher echo amplitudes than the single-step pulse. These improved echo pulses allow us to probe coherence at longer times than in the past, measuring a plateau which has yet to be explained. In addition, we show numerically that the vibrational state coupling due to such lattice manipulations is more efficient in shallow lattices than in deep lattices. The coupling probability for an optimized single-step pulse approaches as the depth goes to infinity (harmonic-oscillator limit), while in shallow lattices with large anharmonicity, the coupling probability reaches a maximum value of 0.51 for a lattice depth of five recoil energies. For square and Gaussian pulses the coupling in the lattice is even stronger, reaching maxima of 0.64 at 6 recoil energies and 0.67 at 5 recoil energies, respectively. - 31 August 2005
- Published by Elsevier in Physica C: Superconductivity and its Applications
- Vol. 426-431, 1385-1389
Voltage–current property of two HTS tapes connected by ordinary Sn–Pb solder
- 31 August 2005
- Published by Elsevier in Physica C: Superconductivity and its Applications
- Vol. 426-431, 1385-1389
Voltage–current property of two HTS tapes connected by ordinary Sn–Pb solder