Byung-Yun Lee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Byung-Yun Lee has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Dong-Seok Lee
Department of Architectural Engineering, Inha University, Incheon 22212, Korea
1 shared publication - Jae-Hun Jo
Division of Architecture, Inha University, Incheon 22212, Republic of Korea
1 shared publication - Jiyoung Park
School of Architecture, Inha University, Incheon 22212, Republic of Korea
1 shared publication - Joon-Gul Oh
Department of Architecture, Seoul National University of Science & Technology, 232 Gongneung-ro, Nowon-gu, Seoul 01811, Korea
1 shared publication - Kyung Sun Lee
School of Architecture, Hongik University, 94 Wausan-ro, Mapo-gu, Seoul 02481, Korea
1 shared publication - Santiago Porras Álvarez
Department of Architecture, Korea University, 145 Anam-ro, Seongbuk-gu, Seoul 02481, Korea
1 shared publication
Latest Publications
- Open Access
- 27 February 2019
- Published by MDPI AG in Sustainability
- Vol. 11 (5) , 1253
Heating, Cooling, and Lighting Energy Demand Simulation Analysis of Kinetic Shading Devices with Automatic Dimming Control for Asian Countries
Kinetic shading devices have recently been introduced for energy-saving and for their innovative appearance. Quantifiable research on kinetic operation systems is necessary to evaluate their applicability in a specific region. This study developed a theoretical methodology for producing an optimal positioning algorithm targeting minimizing total energy demands of kinetic shading devices; the control algorithms for hourly operation were tested through a combined analysis framework of energy performance simulations and spreadsheet analysis. Two common types of external shading devices, vertical-folding and horizontal-rotating types, were simulated in three Asian cities with different climate conditions. Automatic kinetic operation with a consequential dimming control was simulated on the east, south and west facade of an office building, selecting the optimal position every hour based on total energy demand for heating, cooling, and lighting. Comparative simulation analyses for kinetic operation and fixed shading demonstrated that the energy saving potential of fixed shading was greater than that of kinetic operation shading. Kinetic operation was the most applicable in Seoul, where seasonal optimal operation was required for both types of kinetic shadings. In Abu Dhabi and Hanoi, cooling and lighting energy demands were balanced every hour through kinetic operation. Rotating-type kinetic operation in these two regions resulted in better energy-saving performance. The operation frequency pattern of rotating-type kinetic shading provided more active operation and consequent outperformance over the folding-type.
- 27 February 2019
- Published by MDPI AG in Sustainability
- Vol. 11 (5) , 1253
Open AccessHeating, Cooling, and Lighting Energy Demand Simulation Analysis of Kinetic Shading Devices with Automatic Dimming Control for Asian Countries
Kinetic shading devices have recently been introduced for energy-saving and for their innovative appearance. Quantifiable research on kinetic operation systems is necessary to evaluate their applicability in a specific region. This study developed a theoretical methodology for producing an optimal positioning algorithm targeting minimizing total energy demands of kinetic shading devices; the control algorithms for hourly operation were tested through a combined analysis framework of energy performance simulations and spreadsheet analysis. Two common types of external shading devices, vertical-folding and horizontal-rotating types, were simulated in three Asian cities with different climate conditions. Automatic kinetic operation with a consequential dimming control was simulated on the east, south and west facade of an office building, selecting the optimal position every hour based on total energy demand for heating, cooling, and lighting. Comparative simulation analyses for kinetic operation and fixed shading demonstrated that the energy saving potential of fixed shading was greater than that of kinetic operation shading. Kinetic operation was the most applicable in Seoul, where seasonal optimal operation was required for both types of kinetic shadings. In Abu Dhabi and Hanoi, cooling and lighting energy demands were balanced every hour through kinetic operation. Rotating-type kinetic operation in these two regions resulted in better energy-saving performance. The operation frequency pattern of rotating-type kinetic shading provided more active operation and consequent outperformance over the folding-type.
- Open Access
- 27 June 2017
- Published by MDPI AG in Sustainability
- Vol. 9 (7) , 1121
Integration of Sustainability into Architectural Education at Accredited Korean Universities
This paper examines the integration of sustainability principles into architectural education programs at South Korean Universities that have been accredited by the Korea Architectural Accrediting Board (KAAB). Accreditation requires the successful implementation of 30 so-called Student Performance Criteria (SPCs). Similar to recent improvements to international architectural education, different principles of sustainability have been successfully implemented by the KAAB. This paper identifies eight sustainability-related SPCs that can be utilized to teach sustainability. The analysis of 48 accredited five-year architectural education program curricula in South Korea has revealed which sustainability-related SPCs are addressed each semester. Furthermore, the average number of credits per sustainability-related SPC in different course types, such as theory courses and design studios, has been identified. Theory courses with an emphasis on sustainability education have been defined as sustainability core courses. The results reveal that a majority of existing programs primarily address environmental aspects of sustainability. Furthermore, a sequential course structure analysis elucidates three main curriculum types, with different potential for integrated sustainability education in sustainability core courses and design studios: (i) sustainability core course preceding (high potential); (ii) sustainability core courses and design studio, accompanying (high potential); and (iii) sustainability core course following (low potential).
- 27 June 2017
- Published by MDPI AG in Sustainability
- Vol. 9 (7) , 1121
Open AccessIntegration of Sustainability into Architectural Education at Accredited Korean Universities
This paper examines the integration of sustainability principles into architectural education programs at South Korean Universities that have been accredited by the Korea Architectural Accrediting Board (KAAB). Accreditation requires the successful implementation of 30 so-called Student Performance Criteria (SPCs). Similar to recent improvements to international architectural education, different principles of sustainability have been successfully implemented by the KAAB. This paper identifies eight sustainability-related SPCs that can be utilized to teach sustainability. The analysis of 48 accredited five-year architectural education program curricula in South Korea has revealed which sustainability-related SPCs are addressed each semester. Furthermore, the average number of credits per sustainability-related SPC in different course types, such as theory courses and design studios, has been identified. Theory courses with an emphasis on sustainability education have been defined as sustainability core courses. The results reveal that a majority of existing programs primarily address environmental aspects of sustainability. Furthermore, a sequential course structure analysis elucidates three main curriculum types, with different potential for integrated sustainability education in sustainability core courses and design studios: (i) sustainability core course preceding (high potential); (ii) sustainability core courses and design studio, accompanying (high potential); and (iii) sustainability core course following (low potential).
- Open Access
- 10 February 2015
- Published by MDPI AG in Sustainability
- Vol. 7 (2) , 1884-1899
Development of Climate Indices Using Local Weather Data for Shading Design
The energy performance of buildings depends on how effectively the building envelope responds to climate. Architects, therefore, need to design building envelopes with the consideration of local climate characteristics in the early design stage. Simplified formulas were used that evaluate the heating and cooling energy demand of building envelopes, which were applied to a model building with envelope and climate properties according to eight climate zones. Two climate indices, P and S, were developed. P enables the comparison of the heating and cooling energy demand of building envelopes, and S is for comparing the solar heat gain during heating and cooling seasons to review the feasibility of installing shading devices. The physical properties of envelopes were set differently according to the requirements in each climate zone proposed by American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) 90.1. Using local climate data, the P and S of 24 cities over eight climate zones in the United States were derived, which can be used to evaluate the heating and cooling energy characteristics of envelopes. The indices not only enable users to understand the characteristics of the local climate conditions in a simple manner, but also to carry out quantitative assessments on whether shading devices are feasible and, if so, what type is recommended.
- 10 February 2015
- Published by MDPI AG in Sustainability
- Vol. 7 (2) , 1884-1899
Open AccessDevelopment of Climate Indices Using Local Weather Data for Shading Design
The energy performance of buildings depends on how effectively the building envelope responds to climate. Architects, therefore, need to design building envelopes with the consideration of local climate characteristics in the early design stage. Simplified formulas were used that evaluate the heating and cooling energy demand of building envelopes, which were applied to a model building with envelope and climate properties according to eight climate zones. Two climate indices, P and S, were developed. P enables the comparison of the heating and cooling energy demand of building envelopes, and S is for comparing the solar heat gain during heating and cooling seasons to review the feasibility of installing shading devices. The physical properties of envelopes were set differently according to the requirements in each climate zone proposed by American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) 90.1. Using local climate data, the P and S of 24 cities over eight climate zones in the United States were derived, which can be used to evaluate the heating and cooling energy characteristics of envelopes. The indices not only enable users to understand the characteristics of the local climate conditions in a simple manner, but also to carry out quantitative assessments on whether shading devices are feasible and, if so, what type is recommended.