Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Ljubomir Jankovic has a total of 78 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Overheating Risk Assessment of a Future Homes Standard (FHS) Compliant Dwelling Under Current and Future UK Climates

    by Yingchun Ji, Christopher Tsang, Ljubomir Jankovic, Richard Fitton, William Swan, Angela Lee

    This paper investigates the overheating risk of a dwelling designed to meet the UK’s forthcoming Future Homes Standard (FHS). In-situ measurements from co-heating tests conducted within the Energy House 2.0 facility were used to validate a dynamic thermal simulation model. Overheating performance was assessed using both CIBSE TM59 and newly proposed mean nighttime temperature threshold (MNTT) criteria under current and future UK climate scenarios, including different characteristics of summer. The findings indicate that overheating is already evident for highly insulated and airtight FHS-compliant homes, with risk varying considerably across UK locations and climate conditions. The MNTT criteria predicted overheating less frequently than TM59, highlighting differences in assessment outcomes. Window ventilation plays a critical role in mitigating overheating. A step-function control strategy that allows window to open only when outdoor air temperature is lower than indoor air temperature outperforms the ventilation approaches recommended by TM59 and UK Building Regulation Part O, reducing both peak indoor temperatures and the rate of temperature increase. These results suggest that FHS-compliant homes may already fail current overheating criteria in warmer parts of the UK under present-day climates. The study highlights the importance of effective ventilation control and the need to reconcile competing overheating assessment methods as the Future Homes Standard is rolled out.

  • Open Access

    Energy house 2.0: The design, build, commissioning, performance & early findings of a large-scale building physics test facility

    by Richard Fitton, Grant Henshaw, William Swan, Ben Roberts, Toby Le Hunte, Xinyi Zhang, Ljubomir Jankovic

    The global issue of climate change is now readily accepted by most. Buildings contribute 40% of EU emissions, so the need to address mitigation is clear, but changing climate also creates a need for adaptation in buildings. Modelling is an accepted way of estimating the performance of buildings, but issues exist with accuracy and assumptions. This calls for measurements to be made on new build and retrofit homes. However, field measurements can have issues; they are time consuming, expensive, and can also be intrusive. It is for these reasons that the facilities “Salford Energy House” and “Energy House 2.0” were constructed at the University of Salford in the UK. These globally unique facilities allow for full scale homes to be built inside climatic chambers where variables such as temperature, wind, rain, solar radiation, and snow can be replicated, meaning weather conditions experienced by 95% of the worlds populated land mass can be simulated. The chambers are currently home to five structures in total; examining future housing systems, conservatories, window treatments and whole house retrofit scenarios. In this paper we will discuss the design, construction, benefits, limitations, and an overview of research findings from these facilities. Practical application: This paper provides insights and learnings as to how environmental chambers shall be designed, specified, constructed and commissioned to lead to successful facilities, it gives details on some of the issues that were encountered around the energy performance gap. Also, some key learnings are delivered from the initial rounds of research on ASHP and building fabric that are useful for domestic design engineers.

  • Open Access

    Experimental Investigation of Natural Ventilation Rates in a Domestic House in Laboratory Conditions

    by Sara Fateri, Ljubomir Jankovic, Grant Henshaw, William Swan, Richard Fitton

    Stack-driven ventilation is one of the key forms of natural ventilation. Yet, it has rarely been tested at full scale, even though such studies offer critical evidence for validating simplified theoretical models. To investigate stack-driven ventilation experimentally, a full-scale Future Home house was tested under controlled laboratory conditions in an environmental chamber at Energy House 2.0, in the absence of wind and with a stable indoor–outdoor temperature difference. The indoor air was heated to 35 °C, while the surrounding chamber was maintained at 15 °C. Subsequently, six windows were opened simultaneously for 24 h, three on the ground floor and three on the first floor. Air velocities were measured at each opening with hot-wire probes and converted into volumetric flow rates. The total inflow averaged 1.19 m3/s compared with a theoretical prediction of 1.93 m3/s, indicating systematic overestimation by the stack effect equation. A back-calculation suggested a discharge coefficient of 0.37 instead of 0.60. The cooling energy from natural ventilation was quantified and evaluated for its capability to reduce internal air temperature in overheating conditions. The findings increase the understanding of buoyancy-driven ventilation, while underlining the need to calibrate simplified equations against experimental data.


  • Harnessing digital twin for simulation performance analysis, using a hempcrete building

    by Ataitiya Paterson Bana, Ljubomir Jankovic

    The emergence of new technologies has increasingly stimulated advancement in building performance simulation and enables sustainable construction, towards climate change mitigation. This paper harnesses digital twins to investigate simulation performance analysis and consequently, performance gap reduction using a hempcrete building. A monitored hempcrete building is used as the physical object and database system, where relevant monitored data of temperature and relative humidity is obtained. The digital imitation of the hempcrete building is the digital twin that contains static and dynamic data obtained from its physical twin. Also, the measured model interacts with the simulated system and the model then processes the data to extract relevant information for simulation. The digital twin simulation and analysis of the synthesized data is carried out in IES iSCAN. Simulation of the monitored hempcrete building is carried out in IES Virtual Environment. The results will provide insights on calibrated digital twin framework for facilitating simulation performance analysis and optimize hempcrete simulation for energy efficient designs in the built environment.

  • Open Access

    Calibration of Building Performance Simulations for Zero Carbon Ready Homes: Two Open Access Case Studies Under Controlled Conditions

    by Christopher Tsang, Richard Fitton, Xinyi Zhang, Grant Henshaw, Heidi Paola Díaz-Hernández, David Farmer, David Allinson, Anestis Sitmalidis, Mohamed Dgali, Ljubomir Jankovic, et al.

    This study provides a detailed dataset from two modern homes constructed inside an environmentally controlled chamber. These data are used to carefully calibrate a dynamic thermal simulation model of these homes. The calibrated models show good agreement with measurements taken under controlled conditions. The two case study homes, “The Future Home” and “eHome2”, were constructed within the University of Salford’s Energy House 2.0, and high-quality data were collected over eight days. The calibration process involved updating U-values, air permeability rates, and modelling refinements, such as roof ventilation, ground temperatures, and sub-floor void exchange rates, set as boundary conditions. Results demonstrated a high level of accuracy, with performance gaps in whole-house heat transfer coefficient reduced to 0.5% for “The Future Home” and 0.6% for “eHome2”, falling within aggregate heat loss test uncertainty ranges by a significant amount. The study highlights the improved accuracy of calibrated dynamic thermal simulation models, compared to results from the steady-state Standard Assessment Procedure model. By providing openly accessible calibrated models and a clearly defined methodology, this research presents valuable resources for future building performance modelling studies. The findings support the UK’s transition to dynamic modelling approaches proposed in the recently introduced Home Energy Model approach, contributing to improved prediction of energy efficiency and aligning with goals for zero carbon ready and sustainable housing development.


  • Open Access

    A Comparative Analysis of Solar Thermal and Photovoltaic Systems with Heat-Pump Integration in a New-Build House Under Controlled Conditions

    by Christopher Tsang, Ljubomir Jankovic, William Swan, Richard Fitton, Grant Henshaw

    This study investigates the relative benefits of solar thermal (ST) and photovoltaic (PV) systems integrated with air-source heat pumps for domestic hot water production in newly built residential buildings. Using calibrated DesignBuilder simulations of “The Future Home” located in Energy House 2.0, an environmental chamber, the study analyzes energy performance and carbon emissions for eight scenarios: (1) baseline heat pump only, (2) heat pump with 4 m2 PV panels, (3) heat pump with 4 m2 ST panels, (4) heat pump with 2 m2 PV + 2 m2 ST panels, and (5–8) variants with increased hot water demand. While ST systems directly heat water through thermal energy transfer, PV systems contribute to water heating indirectly by providing electricity to power the heat pump. The results show that the ST system provides 964.6 kWh of thermal energy annually, increasing to 1528 kWh with enhanced hot water demand, while a similarly sized PV system generates 532.5 kWh of electricity. The research reveals that Standard Assessment Procedure methodology’s fixed hot water demand assumptions could significantly underpredict solar thermal benefits, potentially discouraging UK house builders from adopting this technology.


  • Open Access

    Heat Transfer Coefficient of a Building: A Constant with Limited Variability or Dynamically Variable?

    by Ljubomir Jankovic, Grant Henshaw, Christopher Tsang, Xinyi Zhang, Richard Fitton, William Swan

    The heat transfer coefficient, or the HTC, is an industry-standard indicator of building energy performance. It is predicated on an assumption that it is of a constant value, and several different methods have been developed to measure and calculate the HTC as a constant. Whilst there are limited variations in the results obtained from these different methods, none of these methods consider a possibility that the HTC could be dynamically variable. Our experimental work shows that the HTC is not a constant. The experimental evidence based on our environmental chambers, which contain detached houses and in which the ambient air temperature can be controlled between −24 °C and +51 °C, with additional relative humidity control and with weather rigs that can introduce solar radiation, rain, and snow, shows that the HTC is dynamically variable. The analysis of data from the fully instrumented and monitored houses in combination with calibrated simulation models and data processing scripts based on genetic algorithm optimization provide experimental evidence of the dynamic variability of the HTC. This research increases the understanding of buildings physics properties and has the potential to change the way the heat transfer coefficient is used in building performance analysis.


  • Open Access

    Heat Transfer Coefficient of a Building: A Constant with Limited Variability or Dynamically Variable?

    by Ljubomir Jankovic, Grant Henshaw, Christopher Tsang, Xinyi Zhang, Richard Fitton, William Swan

    The heat transfer coefficient or the HTC is an industry-standard indicator of building energy performance. It has been predicated on an assumption that it is of a constant value, and several different methods have been developed to measure and calculate the HTC as a constant. Whilst there are limited variations of results obtained from these different methods, none of these methods consider a possibility that the HTC could be dynamically variable. Our experimental work shows that the HTC is not a constant. Experimental evidence base from our environmental chambers, which contain detached houses, and in which ambient air temperature can be controlled between -20 °C and +40 °C, with additional relative humidity control and with weather rigs that can introduce solar radiation, rain and snow, shows that the HTC is dynamically variable. Analysis of data from fully instrumented and monitored houses in a combination with calibrated simulation models and data processing scripts based on genetic algorithm optimization provide experimental evidence of dynamic variability of the HTC. This research increases the understanding of building physics properties and has a potential to change the way the heat transfer coefficient is used in building performance analysis.


  • Open Access

    Calibration of Building Performance Simulations for Zero Carbon Ready Homes: Two Open Access Case Studies in Controlled Conditions

    by Christopher Tsang, Richard Fitton, Xinyi Zhang, Grant Henshaw, Heidi Paola Díaz-Hernández, David Farmer, David Allinson, Anestis Sitmalidis, Mohamed Dagli, Ljubomir Jankovic, et al.


  • Open Access

    A Multi-Objective Design Optimization of a New-Build Future Homes Standard House in Controlled Conditions

    by Christopher Tsang, Ljubomir Jankovic, Richard Fitton, Grant Henshaw

    This paper aims to determine the optimal construction strategies for new-build houses in the UK to minimize heating energy demand and discomfort hours. This research utilizes a previously calibrated model of “The Future Home” in Energy House 2.0’s environmental chamber. Eight design variables were optimized including multiple building fabric specifications, air permeability rates, and heating setpoint temperatures. Three optimization scenarios were investigated: fixed heating setpoints, variable heating setpoints, and variable setpoints with comfort constraints. The analysis revealed that while fixed heating setpoints showed limited optimization potential, variable setpoint scenarios identified three distinct clusters of optimal solutions. The optimization consistently favored superior building fabric parameters, though air permeability solutions became more nuanced with variable heating control. When constrained to a maximum of 400 discomfort hours, solutions required elevated heating setpoints (22–23 °C) while maintaining high fabric specifications. These findings advance building optimization methodology by demonstrating the importance of heating control flexibility and comfort constraints in achieving optimal performance, while the use of a calibrated model in controlled conditions overcomes the limitations of previous studies that relied on uncalibrated or hypothetical models. As in situ field measurements of short- and long-term building performance are often subjected to disruptions, delays, and uncertainties, the building performance research under controlled conditions reported in this article will lead towards the achievement of net zero targets in a timelier manner and with more certainty.