Grant Henshaw
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Grant Henshaw has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
- Richard Fitton
Energy House Labs, University of Salford, Manchester M5 4WT, UK
9 shared publications - Ljubomir Jankovic
Energy House Labs, University of Salford, Manchester M5 4WT, UK
8 shared publications - William Swan
Energy House Labs, University of Salford, Manchester M5 4WT, UK
8 shared publications - Christopher Tsang
Energy House Labs, School of Science, Engineering and Environment, University of Salford, Manchester M5 4WT, UK
6 shared publications Richard Fitton
5 shared publications- David Farmer
Energy House Labs, University of Salford, Manchester M5 4WT, UK
3 shared publications
Latest Publications
- Open Access
Validation of the Heat3D System for Mapping U-Values in Homes Through a Two-Phase Winter Field Trial
Effective evaluation of building fabric is essential to understanding building performance. Traditional methods, such as ISO 9869-1, provide point U-values but do not always capture the complete picture, and new measurement-led approaches are needed to support building retrofit. Heat3D is a novel iOS application that performs rapid U-value measurements of building elements by mapping thermographic images from a mobile infrared camera onto an augmented reality (AR) model of a room, from which heat flux across the element is calculated. A field trial of 22 UK properties during the 2019–2020 winter heating season assessed Heat3D’s heat flux measurements against traditional heat flux plates, with 90% of 295 Heat3D surveys falling within the combined uncertainty of the reference method. A second field trial, conducted over the 2020–2021 winter heating period, evaluated a new timelapse iteration of the method capable of measuring wall U-value within approximately 60 min; 90% of 42 Heat3D surveys fell within the combined confidence interval of the ISO 9869-1-measured U-value. These results indicate that Heat3D offers a viable, rapid alternative to traditional methods for both heat flux and U-value measurement.
Open AccessValidation of the Heat3D System for Mapping U-Values in Homes Through a Two-Phase Winter Field Trial
Effective evaluation of building fabric is essential to understanding building performance. Traditional methods, such as ISO 9869-1, provide point U-values but do not always capture the complete picture, and new measurement-led approaches are needed to support building retrofit. Heat3D is a novel iOS application that performs rapid U-value measurements of building elements by mapping thermographic images from a mobile infrared camera onto an augmented reality (AR) model of a room, from which heat flux across the element is calculated. A field trial of 22 UK properties during the 2019–2020 winter heating season assessed Heat3D’s heat flux measurements against traditional heat flux plates, with 90% of 295 Heat3D surveys falling within the combined uncertainty of the reference method. A second field trial, conducted over the 2020–2021 winter heating period, evaluated a new timelapse iteration of the method capable of measuring wall U-value within approximately 60 min; 90% of 42 Heat3D surveys fell within the combined confidence interval of the ISO 9869-1-measured U-value. These results indicate that Heat3D offers a viable, rapid alternative to traditional methods for both heat flux and U-value measurement.
- Open Access
- 20 March 2026
- Published by Elsevier in Building and Environment
- Vol. 297
Indoor air quality in UK future standard homes: Experimental evaluation of mitigation and ventilation strategies
- 20 March 2026
- Published by Elsevier in Building and Environment
- Vol. 297
Open AccessIndoor air quality in UK future standard homes: Experimental evaluation of mitigation and ventilation strategies
- Open Access
- 30 January 2026
- Published by SAGE Publications in Building Services Engineering Research & Technology
- Vol. 47 (2) , 247-262
Energy house 2.0: The design, build, commissioning, performance & early findings of a large-scale building physics test facility
The global issue of climate change is now readily accepted by most. Buildings contribute 40% of EU emissions, so the need to address mitigation is clear, but changing climate also creates a need for adaptation in buildings. Modelling is an accepted way of estimating the performance of buildings, but issues exist with accuracy and assumptions. This calls for measurements to be made on new build and retrofit homes. However, field measurements can have issues; they are time consuming, expensive, and can also be intrusive. It is for these reasons that the facilities “Salford Energy House” and “Energy House 2.0” were constructed at the University of Salford in the UK. These globally unique facilities allow for full scale homes to be built inside climatic chambers where variables such as temperature, wind, rain, solar radiation, and snow can be replicated, meaning weather conditions experienced by 95% of the worlds populated land mass can be simulated. The chambers are currently home to five structures in total; examining future housing systems, conservatories, window treatments and whole house retrofit scenarios. In this paper we will discuss the design, construction, benefits, limitations, and an overview of research findings from these facilities. Practical application: This paper provides insights and learnings as to how environmental chambers shall be designed, specified, constructed and commissioned to lead to successful facilities, it gives details on some of the issues that were encountered around the energy performance gap. Also, some key learnings are delivered from the initial rounds of research on ASHP and building fabric that are useful for domestic design engineers.
- 30 January 2026
- Published by SAGE Publications in Building Services Engineering Research & Technology
- Vol. 47 (2) , 247-262
Open AccessEnergy house 2.0: The design, build, commissioning, performance & early findings of a large-scale building physics test facility
The global issue of climate change is now readily accepted by most. Buildings contribute 40% of EU emissions, so the need to address mitigation is clear, but changing climate also creates a need for adaptation in buildings. Modelling is an accepted way of estimating the performance of buildings, but issues exist with accuracy and assumptions. This calls for measurements to be made on new build and retrofit homes. However, field measurements can have issues; they are time consuming, expensive, and can also be intrusive. It is for these reasons that the facilities “Salford Energy House” and “Energy House 2.0” were constructed at the University of Salford in the UK. These globally unique facilities allow for full scale homes to be built inside climatic chambers where variables such as temperature, wind, rain, solar radiation, and snow can be replicated, meaning weather conditions experienced by 95% of the worlds populated land mass can be simulated. The chambers are currently home to five structures in total; examining future housing systems, conservatories, window treatments and whole house retrofit scenarios. In this paper we will discuss the design, construction, benefits, limitations, and an overview of research findings from these facilities. Practical application: This paper provides insights and learnings as to how environmental chambers shall be designed, specified, constructed and commissioned to lead to successful facilities, it gives details on some of the issues that were encountered around the energy performance gap. Also, some key learnings are delivered from the initial rounds of research on ASHP and building fabric that are useful for domestic design engineers.
- Open Access
Experimental Investigation of Natural Ventilation Rates in a Domestic House in Laboratory Conditions
Stack-driven ventilation is one of the key forms of natural ventilation. Yet, it has rarely been tested at full scale, even though such studies offer critical evidence for validating simplified theoretical models. To investigate stack-driven ventilation experimentally, a full-scale Future Home house was tested under controlled laboratory conditions in an environmental chamber at Energy House 2.0, in the absence of wind and with a stable indoor–outdoor temperature difference. The indoor air was heated to 35 °C, while the surrounding chamber was maintained at 15 °C. Subsequently, six windows were opened simultaneously for 24 h, three on the ground floor and three on the first floor. Air velocities were measured at each opening with hot-wire probes and converted into volumetric flow rates. The total inflow averaged 1.19 m3/s compared with a theoretical prediction of 1.93 m3/s, indicating systematic overestimation by the stack effect equation. A back-calculation suggested a discharge coefficient of 0.37 instead of 0.60. The cooling energy from natural ventilation was quantified and evaluated for its capability to reduce internal air temperature in overheating conditions. The findings increase the understanding of buoyancy-driven ventilation, while underlining the need to calibrate simplified equations against experimental data.
Open AccessExperimental Investigation of Natural Ventilation Rates in a Domestic House in Laboratory Conditions
Stack-driven ventilation is one of the key forms of natural ventilation. Yet, it has rarely been tested at full scale, even though such studies offer critical evidence for validating simplified theoretical models. To investigate stack-driven ventilation experimentally, a full-scale Future Home house was tested under controlled laboratory conditions in an environmental chamber at Energy House 2.0, in the absence of wind and with a stable indoor–outdoor temperature difference. The indoor air was heated to 35 °C, while the surrounding chamber was maintained at 15 °C. Subsequently, six windows were opened simultaneously for 24 h, three on the ground floor and three on the first floor. Air velocities were measured at each opening with hot-wire probes and converted into volumetric flow rates. The total inflow averaged 1.19 m3/s compared with a theoretical prediction of 1.93 m3/s, indicating systematic overestimation by the stack effect equation. A back-calculation suggested a discharge coefficient of 0.37 instead of 0.60. The cooling energy from natural ventilation was quantified and evaluated for its capability to reduce internal air temperature in overheating conditions. The findings increase the understanding of buoyancy-driven ventilation, while underlining the need to calibrate simplified equations against experimental data.
- 1 December 2025
- Published by Emerald Publishing in International Journal of Building Pathology and Adaptation
- Vol. 44 (6) , 1709-1724
Using thermography to map U-values in homes: a case study of the Heat3D system in controlled conditions
Purpose: This paper provides an alternative approach to ISO 9869-1 (ISO, 2014), measuring U values of buildings, which is time-consuming and costly. Heat3D is a novel application, using thermal imaging to calculate U values. Here, we explain the early stages of the development of the method. Design/methodology/approach: The performance of Heat3D was compared against ISO 9869-1 metrics under controlled conditions to minimise data “noise” from external factors. Findings: The results showed that the application can accurately measure the instantaneous heat flux through a building element, with over 90% of the 200+ Heat3D survey measurements matching that of a calibrated heat flux plate to within their combined uncertainty. Practical implications: Development of a rapid heat flux measurement technique, such as Heat3D, would have benefits such as quantitatively assessing new build or retrofit build quality, sizing heating systems and provide data for updated EPC, which is a forthcoming policy change. Originality/value: There is an emerging literature on quantitative infrared; however, we take a novel approach in using controlled conditions and a highly characterised building to assess the method.
- 1 December 2025
- Published by Emerald Publishing in International Journal of Building Pathology and Adaptation
- Vol. 44 (6) , 1709-1724
Using thermography to map U-values in homes: a case study of the Heat3D system in controlled conditions
Purpose: This paper provides an alternative approach to ISO 9869-1 (ISO, 2014), measuring U values of buildings, which is time-consuming and costly. Heat3D is a novel application, using thermal imaging to calculate U values. Here, we explain the early stages of the development of the method. Design/methodology/approach: The performance of Heat3D was compared against ISO 9869-1 metrics under controlled conditions to minimise data “noise” from external factors. Findings: The results showed that the application can accurately measure the instantaneous heat flux through a building element, with over 90% of the 200+ Heat3D survey measurements matching that of a calibrated heat flux plate to within their combined uncertainty. Practical implications: Development of a rapid heat flux measurement technique, such as Heat3D, would have benefits such as quantitatively assessing new build or retrofit build quality, sizing heating systems and provide data for updated EPC, which is a forthcoming policy change. Originality/value: There is an emerging literature on quantitative infrared; however, we take a novel approach in using controlled conditions and a highly characterised building to assess the method.
- Open Access
The Critical Role of IoT for Enabling the UK’s Built Environment Transition to Net Zero
The built environment contributes approximately 25% of the UK’s total greenhouse gas emissions, positioning it as a critical sector in the national net-zero strategy. This review investigates the enabling role of the domestic smart metering infrastructure combined with other IoT systems in accelerating the decarbonisation of residential buildings. Drawing from experience gained from governmental and commercially funded R&D projects, the article demonstrates how smart metering data can be leveraged to assess building energy performance, underpin cost-effective carbon reduction solutions, and enable energy flexibility services for maintaining grid stability. Unlike controlled laboratory studies, this review article focuses on real-world applications where data from publicly available infrastructure is accessed and utilised, enhancing scalability and policy relevance. The integration of smart meter data with complementary IoT data—such as indoor temperature, weather conditions, and occupancy—substantially improves built environment digital energy analytics. This capability was previously unattainable due to the absence of a nationwide digital energy infrastructure. The insights presented in this work highlight the untapped potential of the UK’s multibillion-pound investment in smart metering, offering a scalable pathway for low-carbon innovation for the built environment, thus supporting the broader transition to a net-zero future.
Open AccessThe Critical Role of IoT for Enabling the UK’s Built Environment Transition to Net Zero
The built environment contributes approximately 25% of the UK’s total greenhouse gas emissions, positioning it as a critical sector in the national net-zero strategy. This review investigates the enabling role of the domestic smart metering infrastructure combined with other IoT systems in accelerating the decarbonisation of residential buildings. Drawing from experience gained from governmental and commercially funded R&D projects, the article demonstrates how smart metering data can be leveraged to assess building energy performance, underpin cost-effective carbon reduction solutions, and enable energy flexibility services for maintaining grid stability. Unlike controlled laboratory studies, this review article focuses on real-world applications where data from publicly available infrastructure is accessed and utilised, enhancing scalability and policy relevance. The integration of smart meter data with complementary IoT data—such as indoor temperature, weather conditions, and occupancy—substantially improves built environment digital energy analytics. This capability was previously unattainable due to the absence of a nationwide digital energy infrastructure. The insights presented in this work highlight the untapped potential of the UK’s multibillion-pound investment in smart metering, offering a scalable pathway for low-carbon innovation for the built environment, thus supporting the broader transition to a net-zero future.
- Open Access
- 22 July 2025
- Published by MDPI AG in Sustainability
- Vol. 17 (15) , 6673
Calibration of Building Performance Simulations for Zero Carbon Ready Homes: Two Open Access Case Studies Under Controlled Conditions
This study provides a detailed dataset from two modern homes constructed inside an environmentally controlled chamber. These data are used to carefully calibrate a dynamic thermal simulation model of these homes. The calibrated models show good agreement with measurements taken under controlled conditions. The two case study homes, “The Future Home” and “eHome2”, were constructed within the University of Salford’s Energy House 2.0, and high-quality data were collected over eight days. The calibration process involved updating U-values, air permeability rates, and modelling refinements, such as roof ventilation, ground temperatures, and sub-floor void exchange rates, set as boundary conditions. Results demonstrated a high level of accuracy, with performance gaps in whole-house heat transfer coefficient reduced to 0.5% for “The Future Home” and 0.6% for “eHome2”, falling within aggregate heat loss test uncertainty ranges by a significant amount. The study highlights the improved accuracy of calibrated dynamic thermal simulation models, compared to results from the steady-state Standard Assessment Procedure model. By providing openly accessible calibrated models and a clearly defined methodology, this research presents valuable resources for future building performance modelling studies. The findings support the UK’s transition to dynamic modelling approaches proposed in the recently introduced Home Energy Model approach, contributing to improved prediction of energy efficiency and aligning with goals for zero carbon ready and sustainable housing development.
- 22 July 2025
- Published by MDPI AG in Sustainability
- Vol. 17 (15) , 6673
Open AccessCalibration of Building Performance Simulations for Zero Carbon Ready Homes: Two Open Access Case Studies Under Controlled Conditions
This study provides a detailed dataset from two modern homes constructed inside an environmentally controlled chamber. These data are used to carefully calibrate a dynamic thermal simulation model of these homes. The calibrated models show good agreement with measurements taken under controlled conditions. The two case study homes, “The Future Home” and “eHome2”, were constructed within the University of Salford’s Energy House 2.0, and high-quality data were collected over eight days. The calibration process involved updating U-values, air permeability rates, and modelling refinements, such as roof ventilation, ground temperatures, and sub-floor void exchange rates, set as boundary conditions. Results demonstrated a high level of accuracy, with performance gaps in whole-house heat transfer coefficient reduced to 0.5% for “The Future Home” and 0.6% for “eHome2”, falling within aggregate heat loss test uncertainty ranges by a significant amount. The study highlights the improved accuracy of calibrated dynamic thermal simulation models, compared to results from the steady-state Standard Assessment Procedure model. By providing openly accessible calibrated models and a clearly defined methodology, this research presents valuable resources for future building performance modelling studies. The findings support the UK’s transition to dynamic modelling approaches proposed in the recently introduced Home Energy Model approach, contributing to improved prediction of energy efficiency and aligning with goals for zero carbon ready and sustainable housing development.
- Open Access
A Comparative Analysis of Solar Thermal and Photovoltaic Systems with Heat-Pump Integration in a New-Build House Under Controlled Conditions
This study investigates the relative benefits of solar thermal (ST) and photovoltaic (PV) systems integrated with air-source heat pumps for domestic hot water production in newly built residential buildings. Using calibrated DesignBuilder simulations of “The Future Home” located in Energy House 2.0, an environmental chamber, the study analyzes energy performance and carbon emissions for eight scenarios: (1) baseline heat pump only, (2) heat pump with 4 m2 PV panels, (3) heat pump with 4 m2 ST panels, (4) heat pump with 2 m2 PV + 2 m2 ST panels, and (5–8) variants with increased hot water demand. While ST systems directly heat water through thermal energy transfer, PV systems contribute to water heating indirectly by providing electricity to power the heat pump. The results show that the ST system provides 964.6 kWh of thermal energy annually, increasing to 1528 kWh with enhanced hot water demand, while a similarly sized PV system generates 532.5 kWh of electricity. The research reveals that Standard Assessment Procedure methodology’s fixed hot water demand assumptions could significantly underpredict solar thermal benefits, potentially discouraging UK house builders from adopting this technology.
Open AccessA Comparative Analysis of Solar Thermal and Photovoltaic Systems with Heat-Pump Integration in a New-Build House Under Controlled Conditions
This study investigates the relative benefits of solar thermal (ST) and photovoltaic (PV) systems integrated with air-source heat pumps for domestic hot water production in newly built residential buildings. Using calibrated DesignBuilder simulations of “The Future Home” located in Energy House 2.0, an environmental chamber, the study analyzes energy performance and carbon emissions for eight scenarios: (1) baseline heat pump only, (2) heat pump with 4 m2 PV panels, (3) heat pump with 4 m2 ST panels, (4) heat pump with 2 m2 PV + 2 m2 ST panels, and (5–8) variants with increased hot water demand. While ST systems directly heat water through thermal energy transfer, PV systems contribute to water heating indirectly by providing electricity to power the heat pump. The results show that the ST system provides 964.6 kWh of thermal energy annually, increasing to 1528 kWh with enhanced hot water demand, while a similarly sized PV system generates 532.5 kWh of electricity. The research reveals that Standard Assessment Procedure methodology’s fixed hot water demand assumptions could significantly underpredict solar thermal benefits, potentially discouraging UK house builders from adopting this technology.
- Open Access
Heat Transfer Coefficient of a Building: A Constant with Limited Variability or Dynamically Variable?
The heat transfer coefficient, or the HTC, is an industry-standard indicator of building energy performance. It is predicated on an assumption that it is of a constant value, and several different methods have been developed to measure and calculate the HTC as a constant. Whilst there are limited variations in the results obtained from these different methods, none of these methods consider a possibility that the HTC could be dynamically variable. Our experimental work shows that the HTC is not a constant. The experimental evidence based on our environmental chambers, which contain detached houses and in which the ambient air temperature can be controlled between −24 °C and +51 °C, with additional relative humidity control and with weather rigs that can introduce solar radiation, rain, and snow, shows that the HTC is dynamically variable. The analysis of data from the fully instrumented and monitored houses in combination with calibrated simulation models and data processing scripts based on genetic algorithm optimization provide experimental evidence of the dynamic variability of the HTC. This research increases the understanding of buildings physics properties and has the potential to change the way the heat transfer coefficient is used in building performance analysis.
Open AccessHeat Transfer Coefficient of a Building: A Constant with Limited Variability or Dynamically Variable?
The heat transfer coefficient, or the HTC, is an industry-standard indicator of building energy performance. It is predicated on an assumption that it is of a constant value, and several different methods have been developed to measure and calculate the HTC as a constant. Whilst there are limited variations in the results obtained from these different methods, none of these methods consider a possibility that the HTC could be dynamically variable. Our experimental work shows that the HTC is not a constant. The experimental evidence based on our environmental chambers, which contain detached houses and in which the ambient air temperature can be controlled between −24 °C and +51 °C, with additional relative humidity control and with weather rigs that can introduce solar radiation, rain, and snow, shows that the HTC is dynamically variable. The analysis of data from the fully instrumented and monitored houses in combination with calibrated simulation models and data processing scripts based on genetic algorithm optimization provide experimental evidence of the dynamic variability of the HTC. This research increases the understanding of buildings physics properties and has the potential to change the way the heat transfer coefficient is used in building performance analysis.
- 2 April 2025
- Published by Springer Nature
- p. 595-605
Variations in the Measured In Situ U-Value of an External Wall Due to Temperature Sensor Location
- 2 April 2025
- Published by Springer Nature
- p. 595-605
Variations in the Measured In Situ U-Value of an External Wall Due to Temperature Sensor Location