Nils Rl Wagenaar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Nils Rl Wagenaar has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Antoon T. M. Willemsen
Department of Nuclear Medicine and Molecular Imaging, Medical Imaging Center, University Medical Center Groningen, University of Groningen, P.O. Box 30001, 9700 RB Groningen, The Netherlands
1 shared publication - Celina Alves
Department of Rheumatology and Clinical Immunology, Ziekenhuisgroep Twente (Hospital Group Twente), Almelo, The Netherlands
1 shared publication - Edgar M. Colin
Hospital Group Twente, Department of Rheumatology and Clinical Immunology, 7600 SZ Almelo, The Netherlands
1 shared publication - Eleonore H de Groot
Department of Nuclear Medicine and Molecular Imaging, University of Groningen, University Medical Center Groningen, P,O, Box 30,001, Groningen 9700 RB, The Netherlands.
1 shared publication - Elisabeth Brouwer
Department of Rheumatology and Clinical Immunology, University Medical Center Groningen, University of Groningen , Groningen
1 shared publication - Gijs D. van Praagh
Department of Nuclear Medicine & Molecular Imaging, Medical Imaging Center, University Medical Center Groningen, University of Groningen, 9713 GZ Groningen, The Netherlands
1 shared publication
Latest Publications
- Open Access
- 27 December 2023
- Published by MDPI AG in Diagnostics
- Vol. 14 (1) , 62
Comparing Diagnostic Performance of Short and Long [18F]FDG-PET Acquisition Times in Giant Cell Arteritis
(1) Background: In giant cell arteritis (GCA), the assessment of cranial arteries using [18F]fluorodeoxyglucose ([18F]FDG) positron emission tomography (PET) combined with low-dose computed tomography (CT) may be challenging due to low image quality. This study aimed to investigate the effect of prolonged acquisition time on the diagnostic performance of [18F]FDG PET/CT in GCA. (2) Methods: Patients with suspected GCA underwent [18F]FDG-PET imaging with a short acquisition time (SAT) and long acquisition time (LAT). Two nuclear medicine physicians (NMPs) reported the presence or absence of GCA according to the overall image impression (gestalt) and total vascular score (TVS) of the cranial arteries. Inter-observer agreement and intra-observer agreement were assessed. (3) Results: In total, 38 patients were included, of whom 20 were diagnosed with GCA and 18 were without it. Sensitivity and specificity for GCA on SAT scans were 80% and 72%, respectively, for the first NMP, and 55% and 89% for the second NMP. On the LAT scans, these values were 65% and 83%, and 75% and 83%, respectively. When using the TVS, LAT scans showed especially increased specificity (94% for both NMPs). Observer agreement was higher on the LAT scans compared with that on the SAT scan. (4) Conclusions: LAT combined with the use of the TVS may decrease the number of false-positive assessments of [18F]FDG PET/CT. Additionally, LAT and TVS may increase both inter and intra-observer agreement.
- 27 December 2023
- Published by MDPI AG in Diagnostics
- Vol. 14 (1) , 62
Open AccessComparing Diagnostic Performance of Short and Long [18F]FDG-PET Acquisition Times in Giant Cell Arteritis
(1) Background: In giant cell arteritis (GCA), the assessment of cranial arteries using [18F]fluorodeoxyglucose ([18F]FDG) positron emission tomography (PET) combined with low-dose computed tomography (CT) may be challenging due to low image quality. This study aimed to investigate the effect of prolonged acquisition time on the diagnostic performance of [18F]FDG PET/CT in GCA. (2) Methods: Patients with suspected GCA underwent [18F]FDG-PET imaging with a short acquisition time (SAT) and long acquisition time (LAT). Two nuclear medicine physicians (NMPs) reported the presence or absence of GCA according to the overall image impression (gestalt) and total vascular score (TVS) of the cranial arteries. Inter-observer agreement and intra-observer agreement were assessed. (3) Results: In total, 38 patients were included, of whom 20 were diagnosed with GCA and 18 were without it. Sensitivity and specificity for GCA on SAT scans were 80% and 72%, respectively, for the first NMP, and 55% and 89% for the second NMP. On the LAT scans, these values were 65% and 83%, and 75% and 83%, respectively. When using the TVS, LAT scans showed especially increased specificity (94% for both NMPs). Observer agreement was higher on the LAT scans compared with that on the SAT scan. (4) Conclusions: LAT combined with the use of the TVS may decrease the number of false-positive assessments of [18F]FDG PET/CT. Additionally, LAT and TVS may increase both inter and intra-observer agreement.
- Open Access
- 1 January 2013
- Published by Springer Nature in EJNMMI Research
- Vol. 3 (1) , 63
Optimized dose regimen for whole-body FDG-PET imaging
The European Association of Nuclear Medicine procedure guidelines for whole-body fluorodeoxyglucose positron-emission tomography (FDG-PET) scanning prescribe a dose proportional to the patient's body mass. However, clinical practice shows degraded image quality in obese patients indicating that using an FDG dose proportional to body mass does not overcome size-related degradation of the image quality. The aim of this study was to optimize the administered FDG dose as a function of the patient's body mass or a different patient-dependent parameter, providing whole-body FDG-PET images of a more constant quality. Using a linear relation between administered dose and body mass, FDG-PET imaging was performed on two PET/computed tomography scanners (Biograph TruePoint and Biograph mCT, Siemens). Image quality was assessed by the signal-to-noise ratio (SNR) in the liver in 102 patients with a body mass of 46 to 130 kg. Moreover, the best correlating patient-dependent parameter was derived, and an optimized FDG dose regimen was determined. This optimized dose regimen was validated on the Biograph TruePoint system in 42 new patients. Furthermore, this relation was verified by a simulation study, in which patients with different body masses were simulated with cylindrical phantoms. As expected, both PET systems showed a significant decrease in SNR with increasing patient's body mass when using a linear dosage. When image quality was fitted to the patient-dependent parameters, the fit with the patient's body mass had the highest R2. The optimized dose regimen was found to be Anew= c/t × m2, where m is the body mass, t is the acquisition time per bed position and c is a constant (depending on scanner type). Using this relation, SNR no longer varied with the patient's body mass. This quadratic relation between dose and body mass was confirmed by the simulation study. A quadratic relation between FDG dose and the patient's body mass is recommended. Both simulations and clinical observations confirm that image quality remains constant across patients when this quadratic dose regimen is used.
- 1 January 2013
- Published by Springer Nature in EJNMMI Research
- Vol. 3 (1) , 63
Open AccessOptimized dose regimen for whole-body FDG-PET imaging
The European Association of Nuclear Medicine procedure guidelines for whole-body fluorodeoxyglucose positron-emission tomography (FDG-PET) scanning prescribe a dose proportional to the patient's body mass. However, clinical practice shows degraded image quality in obese patients indicating that using an FDG dose proportional to body mass does not overcome size-related degradation of the image quality. The aim of this study was to optimize the administered FDG dose as a function of the patient's body mass or a different patient-dependent parameter, providing whole-body FDG-PET images of a more constant quality. Using a linear relation between administered dose and body mass, FDG-PET imaging was performed on two PET/computed tomography scanners (Biograph TruePoint and Biograph mCT, Siemens). Image quality was assessed by the signal-to-noise ratio (SNR) in the liver in 102 patients with a body mass of 46 to 130 kg. Moreover, the best correlating patient-dependent parameter was derived, and an optimized FDG dose regimen was determined. This optimized dose regimen was validated on the Biograph TruePoint system in 42 new patients. Furthermore, this relation was verified by a simulation study, in which patients with different body masses were simulated with cylindrical phantoms. As expected, both PET systems showed a significant decrease in SNR with increasing patient's body mass when using a linear dosage. When image quality was fitted to the patient-dependent parameters, the fit with the patient's body mass had the highest R2. The optimized dose regimen was found to be Anew= c/t × m2, where m is the body mass, t is the acquisition time per bed position and c is a constant (depending on scanner type). Using this relation, SNR no longer varied with the patient's body mass. This quadratic relation between dose and body mass was confirmed by the simulation study. A quadratic relation between FDG dose and the patient's body mass is recommended. Both simulations and clinical observations confirm that image quality remains constant across patients when this quadratic dose regimen is used.