  • Motion in the Unstable Cervical Spine When Transferring a Patient Positioned Prone to a Spine Board

    by Bryan P. Conrad, Diana L. Marchese, Glenn R. Rechtine, Mark Prasarn, Gianluca Del Rossi, MaryBeth H. Horodyski

    Context: Two methods have been proposed to transfer an individual in the prone position to a spine board. Researchers do not know which method provides the best immobilization. Objective: To determine if motion produced in the unstable cervical spine differs between 2 prone logrolling techniques and to evaluate the effect of equipment on the motion produced during prone logrolling. Design: Crossover study. Setting: Laboratory. Patients or Other Participants: Tests were performed on 5 fresh cadavers (3 men, 2 women; age = 83 ± 8 years, mass = 61.2 ± 14.1 kg). Main Outcome Measure(s): Three-dimensional motions were recorded during 2 prone logroll protocols (pull, push) in cadavers with an unstable cervical spine. Three equipment conditions were evaluated: football shoulder pads and helmet, rigid cervical collar, and no equipment. The mean range of motion was calculated for each test condition. Results: The pull technique produced 16% more motion than the push technique in the lateral-bending angulation direction (F1,4 = 19.922, P = .01, η2 = 0.833). Whereas the collar-only condition and, to a lesser extent, the football-shoulder-pads-and-helmet condition demonstrated trends toward providing more stability than the no-equipment condition, we found no differences among equipment conditions. We noted an interaction between technique and equipment, with the pull maneuver performed without equipment producing more anteroposterior motion than the push maneuver in any of the equipment conditions. Conclusions: We saw a slight difference in the motion measured during the 2 prone logrolling techniques tested, with less lateral-bending and anteroposterior motion produced with the logroll push than the pull technique. Therefore, we recommend adopting the push technique as the preferred spine-boarding maneuver when a patient is found in the prone position. Researchers should continue to seek improved methods for performing prone spine-board transfers to further decrease the motion produced in the unstable spine.


  • Open Access

    Effect of plate working length on plate stiffness and cyclic fatigue life in a cadaveric femoral fracture gap model stabilized with a 12-hole 2.4 mm locking compression plate

    by Peini Chao, Bryan P Conrad, Daniel D Lewis, MaryBeth Horodyski, Antonio Pozzi

    Background: There are several factors that can affect the fatigue life of a bone plate, including the mechanical properties of the plate and the complexity of the fracture. The position of the screws can influence construct stiffness, plate strain and cyclic fatigue of the implants. Studies have not investigated these variables in implants utilized for long bone fracture fixation in dogs and cats. The purpose of the present study was to evaluate the effect of plate working length on construct stiffness, gap motion and resistance to cyclic fatigue of dog femora with a simulated fracture gap stabilized using a 12-hole 2.4 mm locking compression plates (LCP). Femora were plated with 12-hole 2.4 mm LCP using 2 screws per fracture segment (long working length group) or with 12-hole 2.4 mm LCP using 5 screws per fracture segment (a short working length group).Results: Construct stiffness did not differ significantly between stabilization techniques. Implant failure did not occur in any of the plated femora during cycling. Mean ± SD yield load at failure in the short plate working length group was significantly higher than in the long plate working length group.Conclusion: In a femoral fracture gap model stabilized with a 2.4 mm LCP applied in contact with the bone, plate working length had no effect on stiffness, gap motion and resistance to fatigue. The short plate working length constructs failed at higher loads; however, yield loads for both the short and long plate working length constructs were within physiologic range.


  • Motion in the Unstable Cervical Spine During Hospital Bed Transfers

    by Bryan P. Conrad, Glenn Rechtine, Mark Weight, Joanne Clarke, MaryBeth Horodyski

    Hospital bed transfers, moves to examination room, X-ray, hospital bed, and/or surgery, have the potential of causing harm to a patient with an unstable cervical spine. This study evaluated motion generated in an unstable segment of the cervical spine during hospital bed transfers. A secondary goal purpose was to assess reduction in cervical motion using three collars and a no collar condition. Cervical spine instability was created at C5-C6 in cadavers. A repeated measures design was used to compare bed transfer techniques: manual transfer performed by six trained individuals and a transfer made by two people using the On3 lateral transfer device. Both techniques were tested under four collar conditions. Cervical spine motion was measured using an electromagnetic motion analysis device with sensors fixed to the anterior bodies of C5 and C6. No significant differences were observed between transfer techniques (flexion, [p = 0.325]; axial rotation [p = 0.590]; lateral bending [p = 0.112]). Nor were there significant differences among the three collars used (flexion [p = 0.462]; axial rotation [p = 0.434]; lateral bending [p = 0.250]). For all transfers, using no collar resulted in more motion than using a collar; but was not statistically significant. Bed transfers made with a lateral transfer device seem to be as safe as those made by the lift and slide manual transfer. None of the collars tested were significantly better at preventing cervical spine motion during a transfer, but each allowed less movement than no collar.


  • Biomechanical Evaluation of the Pullout Strength of Cervical Screws

    by Bryan P Conrad, Andrew G Cordista, MaryBeth Horodyski, Glenn R Rechtine

    In the process of anterior cervical fusion, little is known about the biomechanics of anterior cervical screw pullout. In this study, three different aspects of cervical screw fixation were evaluated: self-tapping (ST) versus self-drilling (SD) screws, the effect of screw geometry (length, diameter, thread pitch), and the use of rescue screws. Nine screws consisting of different diameters, lengths, and thread pitch (cancellous and cortical) were tested in peak pullout force in an artificial bone model using an MTS 858 Mini Bionix test system. Rescue screws (4.5 mm) were then inserted in the failed holes of 4.0-mm screws and extracted to determine their holding strength. Length of screws and thread pitch both had a significant effect on the pullout force. Each 1 mm of increased screw length translates to 16 N of increased force to pullout in the foam bone model. Pullout strength did not vary significantly according to screw diameter or between SD and ST screws. However, the SD screw has an advantage because it can decrease the length of surgery. A decrease in pullout force of between 43% and 70% was found when using rescue screws. In situations in which the use of rescue/salvage screws is required, the surgeon should anticipate a significant decrease in the holding force compared with the original screw. Future directions for research include an evaluation of pullout force for screw and plate constructs.