Weng Kong Chan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Weng Kong Chan has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
Wei Hu
School of Mechanical and Aerospace Engineering, Nanyang Technological University, Republic of Singapore
2 shared publicationsYew-Wah Wong
School of Mechanical & Aerospace Engineering, Nanyang Technological University, Singapore
2 shared publications- Chun Yang
School of Mechanical and Aerospace Engineering Nanyang Technological University Singapore Singapore
1 shared publication - Guiqin Liu
School of MAE, Nanyang Technological University, 50 Nanyang Avenue, Singapore 639798
1 shared publication - Hamed Keramati
Dept. of Biomedical Engineering, King's College London, London, UK; School of Mechanical and Manufacturing Engineering, Faculty of Engineering, The University of New South Wales, Sydney 2052, NSW, Australia
1 shared publication Jianmin Miao
Nanyang Technological University
1 shared publication
Latest Publications
- Open Access
- 19 May 2020
- Published by MDPI AG in Technologies
- Vol. 8 (2) , 29
Engineering Micropatterned Surfaces for Controlling the Evaporation Process of Sessile Droplets
Controlling the evaporation process of a droplet is of the utmost importance for a number of technologies. Also, along with the advances of microfabrication, micropatterned surfaces have emerged as an important technology platform to tune the wettability and other surface properties of various fundamental and applied applications. Among the geometrical parameters of these micropatterns, it is of great interest to investigate whether the arrangement of the patterns would affect the evaporation process of a sessile liquid droplet. To address this question, we fabricated four microhole arrays with different arrangements, quantified by the parameter of “eccentricity”. The results suggested that, compared to smooth substrates, the evaporation mode was not only affected by engineering the microhole arrays, but also by the eccentricity of these micropatterns. The values of contact angle hysteresis (CAH) were used to quantify and test this hypothesis. The CAH could partially explain the different evaporation modes observed on the microhole arrays with zero and non-zero values of eccentricity. That is, on microhole arrays with zero eccentricity, CAH of water droplets was comparatively low (less than 20 ). Consistently, during the evaporation, around 60% of the life span of the droplet was in the mixed evaporation mode. Increasing the eccentricity of the microhole arrays increases the values of CAH to above 20 . Unlike the increasing trend of CAH, the evaporation modes of sessile droplets on the microhole array with non-zero values of eccentricity were almost similar. Over 75% of the life span of droplets on these surfaces was in constant contact line (CCL) mode. Our findings play a significant role in any technology platform containing micropatterned surfaces, where controlling the evaporation mode is desirable.- 19 May 2020
- Published by MDPI AG in Technologies
- Vol. 8 (2) , 29
Open AccessEngineering Micropatterned Surfaces for Controlling the Evaporation Process of Sessile Droplets
Controlling the evaporation process of a droplet is of the utmost importance for a number of technologies. Also, along with the advances of microfabrication, micropatterned surfaces have emerged as an important technology platform to tune the wettability and other surface properties of various fundamental and applied applications. Among the geometrical parameters of these micropatterns, it is of great interest to investigate whether the arrangement of the patterns would affect the evaporation process of a sessile liquid droplet. To address this question, we fabricated four microhole arrays with different arrangements, quantified by the parameter of “eccentricity”. The results suggested that, compared to smooth substrates, the evaporation mode was not only affected by engineering the microhole arrays, but also by the eccentricity of these micropatterns. The values of contact angle hysteresis (CAH) were used to quantify and test this hypothesis. The CAH could partially explain the different evaporation modes observed on the microhole arrays with zero and non-zero values of eccentricity. That is, on microhole arrays with zero eccentricity, CAH of water droplets was comparatively low (less than 20 ). Consistently, during the evaporation, around 60% of the life span of the droplet was in the mixed evaporation mode. Increasing the eccentricity of the microhole arrays increases the values of CAH to above 20 . Unlike the increasing trend of CAH, the evaporation modes of sessile droplets on the microhole array with non-zero values of eccentricity were almost similar. Over 75% of the life span of droplets on these surfaces was in constant contact line (CCL) mode. Our findings play a significant role in any technology platform containing micropatterned surfaces, where controlling the evaporation mode is desirable. - 4 October 2018
- Published by ASME International in Journal of Fluids Engineering
- Vol. 141 (3)
Effects of Flow Coefficient on Miniature Centrifugal Pump Performance
In order to help the design of miniature centrifugal pumps, the design method for macrosize centrifugal pumps is reviewed and the critical parameter, the flow coefficient, is examined in this paper for the miniature centrifugal pumps. The performance of the pumps designed is analyzed theoretically, numerically, and experimentally. Both numerical and theoretical results show that the value of the optimized flow coefficient is approximately 1.47. This value is about five times larger than the recommended value using conventional design technique for macrosize pumps. The optimum radius ratio obtained numerically is approximately 0.4. It can be concluded that the design approach for macrosize pumps is not applicable for pumps in the scale of decimeters. The results obtained in the present study provide us guidelines on the design and performance study of the miniature centrifugal pump.
- 4 October 2018
- Published by ASME International in Journal of Fluids Engineering
- Vol. 141 (3)
Effects of Flow Coefficient on Miniature Centrifugal Pump Performance
In order to help the design of miniature centrifugal pumps, the design method for macrosize centrifugal pumps is reviewed and the critical parameter, the flow coefficient, is examined in this paper for the miniature centrifugal pumps. The performance of the pumps designed is analyzed theoretically, numerically, and experimentally. Both numerical and theoretical results show that the value of the optimized flow coefficient is approximately 1.47. This value is about five times larger than the recommended value using conventional design technique for macrosize pumps. The optimum radius ratio obtained numerically is approximately 0.4. It can be concluded that the design approach for macrosize pumps is not applicable for pumps in the scale of decimeters. The results obtained in the present study provide us guidelines on the design and performance study of the miniature centrifugal pump.
- 23 February 2017
- Published by Springer Nature in Microsystem Technologies
- Vol. 23 (12) , 5717-5725
Fabrication and performance characterization of miniature axial fans
- 23 February 2017
- Published by Springer Nature in Microsystem Technologies
- Vol. 23 (12) , 5717-5725
Fabrication and performance characterization of miniature axial fans
- Open Access
- 11 June 2013
- Published by Springer Nature in Discover Nano
- Vol. 8 (1) , 282
Dynamic contact angle of water-based titanium oxide nanofluid
This paper presents an investigation into spreading dynamics and dynamic contact angle of TiO2-deionized water nanofluids. Two mechanisms of energy dissipation, (1) contact line friction and (2) wedge film viscosity, govern the dynamics of contact line motion. The primary stage of spreading has the contact line friction as the dominant dissipative mechanism. At the secondary stage of spreading, the wedge film viscosity is the dominant dissipative mechanism. A theoretical model based on combination of molecular kinetic theory and hydrodynamic theory which incorporates non-Newtonian viscosity of solutions is used. The model agreement with experimental data is reasonable. Complex interparticle interactions, local pinning of the contact line, and variations in solid–liquid interfacial tension are attributed to errors.
- 11 June 2013
- Published by Springer Nature in Discover Nano
- Vol. 8 (1) , 282
Open AccessDynamic contact angle of water-based titanium oxide nanofluid
This paper presents an investigation into spreading dynamics and dynamic contact angle of TiO2-deionized water nanofluids. Two mechanisms of energy dissipation, (1) contact line friction and (2) wedge film viscosity, govern the dynamics of contact line motion. The primary stage of spreading has the contact line friction as the dominant dissipative mechanism. At the secondary stage of spreading, the wedge film viscosity is the dominant dissipative mechanism. A theoretical model based on combination of molecular kinetic theory and hydrodynamic theory which incorporates non-Newtonian viscosity of solutions is used. The model agreement with experimental data is reasonable. Complex interparticle interactions, local pinning of the contact line, and variations in solid–liquid interfacial tension are attributed to errors.
- 15 June 2007
- Published by Wiley in Artificial Organs
- Vol. 31 (8) , 639-645
Effects of Tongue Position and Base Circle Diameter on the Performance of a Centrifugal Blood Pump
Abstract: This article presents numerical investigations of the effect of radial gap and volute tongue position on the circumferential pressure distribution and the magnitude of resulting imbalanced radial force. A series of volute models was designed using the constant mean velocity method. The results indicate that a radial clearance of 10% is a good practical value that gives a relatively high head across the pump for a small radial force. The results show that the tongue position at 30 degrees gives the lowest radial force and pressure head. The tongue position at 15 degrees appears to give the best compromise results producing a generated head only 5% less than the maximum value while the radial force is about 22% less than the maximum force.
- 15 June 2007
- Published by Wiley in Artificial Organs
- Vol. 31 (8) , 639-645
Effects of Tongue Position and Base Circle Diameter on the Performance of a Centrifugal Blood Pump
Abstract: This article presents numerical investigations of the effect of radial gap and volute tongue position on the circumferential pressure distribution and the magnitude of resulting imbalanced radial force. A series of volute models was designed using the constant mean velocity method. The results indicate that a radial clearance of 10% is a good practical value that gives a relatively high head across the pump for a small radial force. The results show that the tongue position at 30 degrees gives the lowest radial force and pressure head. The tongue position at 15 degrees appears to give the best compromise results producing a generated head only 5% less than the maximum value while the radial force is about 22% less than the maximum force.
- 25 April 2007
- Published by Wiley in Artificial Organs
- Vol. 31 (6) , 434-440
Numerical and In Vitro Investigations of Pressure Rise in a New Hydrodynamic Blood Bearing
Abstract: The reliability and simplicity of rotor bearing are vital to the success of long‐term implantation of rotary blood pumps. This article describes both numerical and in vitro studies of the pressure rise in a 5‐cm‐diameter spiral groove bearing. Results show that the simplified analytical model overpredicts the pressure rise across the bearing while the results from a more comprehensive three‐dimensional computational fluid dynamics (CFD) model agree well with the measurements. The discrepancy between the analytical model and the measurements is attributed to the exclusion of the fluid inertia effects in the analytical model. In addition, the assumption of linear pressure variations at the entrance of the groove and the ridge may have oversimplified the analysis. CFD results show that the pressure variation at the entrance of the groove and ridge is nonlinear. A correction factor taking into consideration the fluid inertia effect has been incorporated, and the modified analytical results agreed well with the measurement as well as that of the more comprehensive CFD model. The pressure generated is sufficient to lift the rotor, and this design provides the designer an alternative design for passive bearing.
- 25 April 2007
- Published by Wiley in Artificial Organs
- Vol. 31 (6) , 434-440
Numerical and In Vitro Investigations of Pressure Rise in a New Hydrodynamic Blood Bearing
Abstract: The reliability and simplicity of rotor bearing are vital to the success of long‐term implantation of rotary blood pumps. This article describes both numerical and in vitro studies of the pressure rise in a 5‐cm‐diameter spiral groove bearing. Results show that the simplified analytical model overpredicts the pressure rise across the bearing while the results from a more comprehensive three‐dimensional computational fluid dynamics (CFD) model agree well with the measurements. The discrepancy between the analytical model and the measurements is attributed to the exclusion of the fluid inertia effects in the analytical model. In addition, the assumption of linear pressure variations at the entrance of the groove and the ridge may have oversimplified the analysis. CFD results show that the pressure variation at the entrance of the groove and ridge is nonlinear. A correction factor taking into consideration the fluid inertia effect has been incorporated, and the modified analytical results agreed well with the measurement as well as that of the more comprehensive CFD model. The pressure generated is sufficient to lift the rotor, and this design provides the designer an alternative design for passive bearing.
- 1 May 2006
- Published by Wiley in Artificial Organs
- Vol. 30 (5) , 354-359
A Review of Leakage Flow in Centrifugal Blood Pumps
This article presents a new approach in determining the functional relationship between the leakage flow in a centrifugal blood pump and various parameters that affect it. While high leakage flow in a blood pump is essential for good washout and can help prevent thrombus formation, excessive leakage flow will result in higher fluid shear stress that may lead to hemolysis. Dimensional analysis is employed to provide a functional relationship between leakage flow rate and other important parameters governing the operation of a centrifugal blood pump. Results showed that pump performance with a smaller gap clearance is clearly superior compared to those of two other similar pumps with larger gap clearances. It was also observed that the nondimensional leakage flow rate varies almost linearly with dimensionless pump head. It also decreases with increasing volume flow rate. A smaller gap clearance will also increase the flow resistance and hence, decrease the nondimensional leakage flow rate. Increasing surface roughness, length of the gap clearance passage, or loss coefficient of the gap geometry will increase losses and hence, decrease the leakage flow rate. It is also interesting to note that for a given pump and gap clearance geometry, the nondimensional leakage flow rate is almost independent of the Reynolds number when specific speed is constant.
- 1 May 2006
- Published by Wiley in Artificial Organs
- Vol. 30 (5) , 354-359
A Review of Leakage Flow in Centrifugal Blood Pumps
This article presents a new approach in determining the functional relationship between the leakage flow in a centrifugal blood pump and various parameters that affect it. While high leakage flow in a blood pump is essential for good washout and can help prevent thrombus formation, excessive leakage flow will result in higher fluid shear stress that may lead to hemolysis. Dimensional analysis is employed to provide a functional relationship between leakage flow rate and other important parameters governing the operation of a centrifugal blood pump. Results showed that pump performance with a smaller gap clearance is clearly superior compared to those of two other similar pumps with larger gap clearances. It was also observed that the nondimensional leakage flow rate varies almost linearly with dimensionless pump head. It also decreases with increasing volume flow rate. A smaller gap clearance will also increase the flow resistance and hence, decrease the nondimensional leakage flow rate. Increasing surface roughness, length of the gap clearance passage, or loss coefficient of the gap geometry will increase losses and hence, decrease the leakage flow rate. It is also interesting to note that for a given pump and gap clearance geometry, the nondimensional leakage flow rate is almost independent of the Reynolds number when specific speed is constant.
- 23 November 2005
- Published by Wiley in Artificial Organs
- Vol. 29 (12) , 937-948
Design Considerations of Volute Geometry of a Centrifugal Blood Pump
This article compares two different design techniques that are conventionally used in the design of volutes for centrifugal pumps. The imbalanced forces due to the geometry of the volute need to be taken into consideration especially in centrifugal blood pumps with magnetically suspended impeller. A reduction of these forces can reduce the instability of the impeller motion as well as the power needed to counteract its influence. Volutes using the constant angular momentum (CAM) and the constant mean velocity (CMV) methods were developed and modeled numerically. The computational results on the effect of volute geometry on the performance of a centrifugal blood pump impeller for six different volutes are presented here. For volutes designed using the CAM method, model B (volute expansion angle of 3°) had the lowest radial force of 0.26 N while the pressure head generated was 12 900 Pa. For volutes designed using the CMV method, model F (1.6 m/s) had the lowest imbalanced force of 0.45 N. However, the pressure developed by this pump was also one of the lowest at 10 652 Pa. Furthermore, when the peak scalar stresses and the mean exposure time of particles for all designs were determined using Lagrangian particle tracking method, it was observed that in general, the peak scalar stresses in CAM designed volutes are lower than those designed using CMV method. The mean exposure time of particles in the pump ranged from 400 to 500 ms. The simulation results showed that the volute designed using CAM method was superior to that of a CMV volute in terms of the magnitude of the radial force and the peak scalar stresses for the same pressure head generated. Results show that the design of volutes for blood pumps should go beyond conventional empirical methods to obtain optimal results.
- 23 November 2005
- Published by Wiley in Artificial Organs
- Vol. 29 (12) , 937-948
Design Considerations of Volute Geometry of a Centrifugal Blood Pump
This article compares two different design techniques that are conventionally used in the design of volutes for centrifugal pumps. The imbalanced forces due to the geometry of the volute need to be taken into consideration especially in centrifugal blood pumps with magnetically suspended impeller. A reduction of these forces can reduce the instability of the impeller motion as well as the power needed to counteract its influence. Volutes using the constant angular momentum (CAM) and the constant mean velocity (CMV) methods were developed and modeled numerically. The computational results on the effect of volute geometry on the performance of a centrifugal blood pump impeller for six different volutes are presented here. For volutes designed using the CAM method, model B (volute expansion angle of 3°) had the lowest radial force of 0.26 N while the pressure head generated was 12 900 Pa. For volutes designed using the CMV method, model F (1.6 m/s) had the lowest imbalanced force of 0.45 N. However, the pressure developed by this pump was also one of the lowest at 10 652 Pa. Furthermore, when the peak scalar stresses and the mean exposure time of particles for all designs were determined using Lagrangian particle tracking method, it was observed that in general, the peak scalar stresses in CAM designed volutes are lower than those designed using CMV method. The mean exposure time of particles in the pump ranged from 400 to 500 ms. The simulation results showed that the volute designed using CAM method was superior to that of a CMV volute in terms of the magnitude of the radial force and the peak scalar stresses for the same pressure head generated. Results show that the design of volutes for blood pumps should go beyond conventional empirical methods to obtain optimal results.
- 1 March 2005
- Published by Wiley in Artificial Organs
- Vol. 29 (3) , 250-258
Numerical Investigation of the Effects of the Clearance Gap Between the Inducer and Impeller of an Axial Blood Pump
A series of numerical models are generated to investigate the flow characteristics and performance of an axial blood pump. The pump model includes a straightener, an inducer-impeller, and diffuser. Numerical studies of the effects of angular alignment of the inducer and impeller blades and the axial clearance gap between the inducer and impeller are presented in this article. The pump characteristics derived from numerical simulation are validated with experimental data. Numerically simulated results showed a sinusoidal variation in the pressure generated across the pump with changes in angular alignment between the inducer and impeller. This is attributed to additional losses when flow is forced or diverted from the trailing edge of the inducer to either the pressure or suction side of the impeller blade when the alignment between the two sets of blades is not optimal. The pressure generated is a maximum when the impeller blades are at 0 or 30 degrees with respect to the inducer. The effect of rotating the impeller with respect to the inducer causes the sinusoidal pressure variation. In addition, it was observed that when the clearance gap between the inducer and impeller is reduced to 1 mm, the pressure generated is a minimum when compared to the other models. This is attributed to the interference between the inducer and impeller when the gap separating them is too small. The location of the maximum pressure on the pressure side of the impeller blade shifts upstream while its magnitude decreases for small clearance gap between the inducer and the impeller. There was no flow separation in the inducer while small regions of backflow are observed at the impeller trailing edge. Recommendations for future modifications and improvements to the pump design and model simulation are also given.
- 1 March 2005
- Published by Wiley in Artificial Organs
- Vol. 29 (3) , 250-258
Numerical Investigation of the Effects of the Clearance Gap Between the Inducer and Impeller of an Axial Blood Pump
A series of numerical models are generated to investigate the flow characteristics and performance of an axial blood pump. The pump model includes a straightener, an inducer-impeller, and diffuser. Numerical studies of the effects of angular alignment of the inducer and impeller blades and the axial clearance gap between the inducer and impeller are presented in this article. The pump characteristics derived from numerical simulation are validated with experimental data. Numerically simulated results showed a sinusoidal variation in the pressure generated across the pump with changes in angular alignment between the inducer and impeller. This is attributed to additional losses when flow is forced or diverted from the trailing edge of the inducer to either the pressure or suction side of the impeller blade when the alignment between the two sets of blades is not optimal. The pressure generated is a maximum when the impeller blades are at 0 or 30 degrees with respect to the inducer. The effect of rotating the impeller with respect to the inducer causes the sinusoidal pressure variation. In addition, it was observed that when the clearance gap between the inducer and impeller is reduced to 1 mm, the pressure generated is a minimum when compared to the other models. This is attributed to the interference between the inducer and impeller when the gap separating them is too small. The location of the maximum pressure on the pressure side of the impeller blade shifts upstream while its magnitude decreases for small clearance gap between the inducer and the impeller. There was no flow separation in the inducer while small regions of backflow are observed at the impeller trailing edge. Recommendations for future modifications and improvements to the pump design and model simulation are also given.
- 1 December 2001
- Published by Springer Nature in KSME International Journal
- Vol. 15 (12) , 1869-1875
Visualization of relative flow patterns in centrifugal blood pump
- 1 December 2001
- Published by Springer Nature in KSME International Journal
- Vol. 15 (12) , 1869-1875
Visualization of relative flow patterns in centrifugal blood pump