Juliane Riewe
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Juliane Riewe has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Andreas Dietzel
Institute of Microtechnology, TU Braunschweig, Braunschweig, Germany
2 shared publications - Heike Bunjes
Technische Universität Braunschweig, Institut für Pharmazeutische Technologie und Biopharmazie, Mendelssohnstr. 1, 38106 Braunschweig, Germany; Technische Universität Braunschweig, Zentrum für Pharmaverfahrenstechnik - PVZ, Franz-Liszt-Str. 35a, 38106 Braunschweig, Germany
2 shared publications - Peer Erfle
Technische Universität Braunschweig, Institut für Mikrotechnik
2 shared publications - Holger Bolze
Max Planck Institute for Biophysical Chemistry, Göttingen 37077, Germany
1 shared publication - Thomas P. Burg
Max Planck Institute for Biophysical Chemistry
1 shared publication
Latest Publications
- Open Access
- 27 March 2019
- Published by MDPI AG in Micromachines
- Vol. 10 (4) , 220
Stabilized Production of Lipid Nanoparticles of Tunable Size in Taylor Flow Glass Devices with High-Surface-Quality 3D Microchannels
Nanoparticles as an application platform for active ingredients offer the advantage of efficient absorption and rapid dissolution in the organism, even in cases of poor water solubility. Active substances can either be presented directly as nanoparticles or can be integrated in a colloidal carrier system (e.g., lipid nanoparticles). For bottom-up nanoparticle production minimizing particle contamination, precipitation processes provide an adequate approach. Microfluidic systems ensure a precise control of mixing for the precipitation, which enables a tunable particle size definition. In this work, a gas/liquid Taylor flow micromixer made of chemically inert glass is presented, in which the organic phases are injected through a symmetric inlet structure. The 3D structuring of the glass was performed by femtosecond laser ablation. Rough microchannel walls are typically obtained by laser ablation but were smoothed by a subsequent annealing process resulting in lower hydrophilicity and even rounder channel cross-sections. Only with such smooth channel walls can a substantial reduction of fouling be obtained, allowing for stable operation over longer periods. The ultrafast mixing of the solutions could be adjusted by simply changing the gas volume flow rate. Narrow particle size distributions are obtained for smaller gas bubbles with a low backflow and when the rate of liquid volume flow has a small influence on particle precipitation. Therefore, nanoparticles with adjustable sizes of down to 70 nm could be reliably produced in continuous mode. Particle size distributions could be narrowed to a polydispersity value of 0.12.
- 27 March 2019
- Published by MDPI AG in Micromachines
- Vol. 10 (4) , 220
Open AccessStabilized Production of Lipid Nanoparticles of Tunable Size in Taylor Flow Glass Devices with High-Surface-Quality 3D Microchannels
Nanoparticles as an application platform for active ingredients offer the advantage of efficient absorption and rapid dissolution in the organism, even in cases of poor water solubility. Active substances can either be presented directly as nanoparticles or can be integrated in a colloidal carrier system (e.g., lipid nanoparticles). For bottom-up nanoparticle production minimizing particle contamination, precipitation processes provide an adequate approach. Microfluidic systems ensure a precise control of mixing for the precipitation, which enables a tunable particle size definition. In this work, a gas/liquid Taylor flow micromixer made of chemically inert glass is presented, in which the organic phases are injected through a symmetric inlet structure. The 3D structuring of the glass was performed by femtosecond laser ablation. Rough microchannel walls are typically obtained by laser ablation but were smoothed by a subsequent annealing process resulting in lower hydrophilicity and even rounder channel cross-sections. Only with such smooth channel walls can a substantial reduction of fouling be obtained, allowing for stable operation over longer periods. The ultrafast mixing of the solutions could be adjusted by simply changing the gas volume flow rate. Narrow particle size distributions are obtained for smaller gas bubbles with a low backflow and when the rate of liquid volume flow has a small influence on particle precipitation. Therefore, nanoparticles with adjustable sizes of down to 70 nm could be reliably produced in continuous mode. Particle size distributions could be narrowed to a polydispersity value of 0.12.
- Open Access
- 9 March 2019
- Published by MDPI AG in Micromachines
- Vol. 10 (3) , 179
A Microfluidic Split-Flow Technology for Product Characterization in Continuous Low-Volume Nanoparticle Synthesis
A key aspect of microfluidic processes is their ability to perform chemical reactions in small volumes under continuous flow. However, a continuous process requires stable reagent flow over a prolonged period. This can be challenging in microfluidic systems, as bubbles or particles easily block or alter the flow. Online analysis of the product stream can alleviate this problem by providing a feedback signal. When this signal exceeds a pre-defined range, the process can be re-adjusted or interrupted to prevent contamination. Here we demonstrate the feasibility of this concept by implementing a microfluidic detector downstream of a segmented-flow system for the synthesis of lipid nanoparticles. To match the flow rate through the detector to the measurement bandwidth independent of the synthesis requirements, a small stream is sidelined from the original product stream and routed through a measuring channel with 2 × 2 µm cross-section. The small size of the measuring channel prevents the entry of air plugs, which are inherent to our segmented flow synthesis device. Nanoparticles passing through the small channel were detected and characterized by quantitative fluorescence measurements. With this setup, we were able to count single nanoparticles. This way, we were able to detect changes in the particle synthesis affecting the size, concentration, or velocity of the particles in suspension. We envision that the flow-splitting scheme demonstrated here can be transferred to detection methods other than fluorescence for continuous monitoring and feedback control of microfluidic nanoparticle synthesis.
- 9 March 2019
- Published by MDPI AG in Micromachines
- Vol. 10 (3) , 179
Open AccessA Microfluidic Split-Flow Technology for Product Characterization in Continuous Low-Volume Nanoparticle Synthesis
A key aspect of microfluidic processes is their ability to perform chemical reactions in small volumes under continuous flow. However, a continuous process requires stable reagent flow over a prolonged period. This can be challenging in microfluidic systems, as bubbles or particles easily block or alter the flow. Online analysis of the product stream can alleviate this problem by providing a feedback signal. When this signal exceeds a pre-defined range, the process can be re-adjusted or interrupted to prevent contamination. Here we demonstrate the feasibility of this concept by implementing a microfluidic detector downstream of a segmented-flow system for the synthesis of lipid nanoparticles. To match the flow rate through the detector to the measurement bandwidth independent of the synthesis requirements, a small stream is sidelined from the original product stream and routed through a measuring channel with 2 × 2 µm cross-section. The small size of the measuring channel prevents the entry of air plugs, which are inherent to our segmented flow synthesis device. Nanoparticles passing through the small channel were detected and characterized by quantitative fluorescence measurements. With this setup, we were able to count single nanoparticles. This way, we were able to detect changes in the particle synthesis affecting the size, concentration, or velocity of the particles in suspension. We envision that the flow-splitting scheme demonstrated here can be transferred to detection methods other than fluorescence for continuous monitoring and feedback control of microfluidic nanoparticle synthesis.