DSDaniella Cristo Santin

Daniella Cristo Santin

*This is an algorithmically generated author record based on publicly available information.

Daniella Cristo Santin has a total of 29 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Perception and Knowledge of Dental Students and Dentists on the Management of Non‐Carious Cervical Lesions: A Cross‐Sectional Study

    by Daniella Cristo Santin, Victor Mosquim, Juliana Carvalho Jacomine, Mylena Proença Costa, Heitor Marques Honório, Linda Wang

    Introduction: The combination of mechanical and chemical stress may lead to the development of non‐carious cervical lesions (NCCLs), which can be challenging to manage. Professional scientific and technical mastery is essential, requiring close attention to knowledge development from the undergraduate learning process. Objectives: This study aimed to (1) assess the knowledge of undergraduate dental students and dentists about the aetiology, diagnosis, and treatment of NCCLs; (2) compare self‐reported and actual knowledge scores between the groups; and (3) identify the factors influencing these scores. Methods: After development and pilot testing, 70 dental students and 131 dentists from Brazil answered the electronic questionnaire with multiple‐choice questions. The data were analysed descriptively and statistically using multiple linear regression analyses, with the actual knowledge score as the dependent variable. Results: The students overestimated their knowledge compared to their actual performance, whereas dentists' self‐reported and actual knowledge scores were statistically similar. Dentists' actual knowledge values were significantly higher than those of undergraduate students. Additionally, the institution's region and type (public or private) represented the independent variables in the final regression model for undergraduates. Conclusions: Brazilian undergraduate dental students and dentists have limited knowledge of NCCLs, and students overestimated their self‐reported knowledge. These findings highlight the relevance of effectively integrating theoretical knowledge with clinical practice to improve the training of future professionals and enhance clinical decision‐making.

  • Performance of low-viscosity resin composites containing S-PRG fillers under erosive challenge

    by Daniella Cristo Santin, Juliana Carvalho Jacomine, Leonardo Masiero Fogaça, Marina Ciccone Giacomini, Heitor Marques Honório, Linda Wang

    Objectives To characterize restorative materials, including low-viscosity resin composites containing or not S-PRG fillers, under erosive challenge. Methods Specimens of glass-ionomer (GC Gold Label 2–GL), resin composites without (Filtek Supreme Flowable Restorative–FSF; Filtek Bulk Fill Flowable Restorative–FBF) and with S-PRG fillers (Beautifil Flow Plus F00–F00 and Beautifil Bulk Flowable–BBF) were prepared. Materials were assessed for color stability (CIELab/CIEDE 2000), Knoop microhardness (KHN), flexural strength (FS), elastic modulus (E) and Energy Dispersive Spectroscopy (EDS) before and after cycling in orange juice (3 cycles/5min/5 days). Shrinkage stress (SS) was assessed to complement their characterization. Results Material, storage condition and their interaction were significant for most tests (p < 0.05). Under acidic conditions, GL was more vulnerable, with color change, reduced KHN, and elemental loss. Resin composites maintained both color stability and microhardness after erosive challenge. Among them, BBF and F00 exhibited higher KHN values than FBF. GL and BBF showed stable FS, while the elastic modulus increased for all materials except BBF. BBF also showed the lowest SS compared to FBF and GL. Conclusions Low-viscosity resin composites, in particular containing S-PRG fillers were able to resist under erosive challenge. BBF presented the best balance of color stability, resistance and low SS among the tested materials. Clinical significance The bulk-fill resin composite containing S-PRG fillers represents a promising restorative strategy for cervical erosive lesions, combining resistance to surface degradation with reduced shrinkage stress that may help preserve the adhesive interface.


  • Open Access

    Analysis of color stability and degree of conversion of different types of resin composites

    by Mylena Proença Costa, Juliana Carvalho Jacomine, Victor Mosquim, Daniella Cristo Santin, Giovanna Speranza Zabeu, Maria Angélica Silvério Agulhari, Rafael Francisco Lia Mondelli, Heitor Marques Honório, Linda Wang

    Resin composites containing surface pre-reacted glass (S-PRG) have been introduced to reduce demineralization and improve remineralization of the tooth structure. However, water diffusion within the material is necessary for its action, which can impair its overall physicomechanical properties over time, including color stability. This study aimed to evaluate the color stability and related degree of conversion (DC) of four resin composites. Discs (6 x 4 mm, n = 5/group) of microhybrid (MH), nanofilled (NF), nanohybrid (NH), and S-PRG-based nanohybrid (S-PRG-NH) composites with two opacities (A2/A2E and A2O/A2D) were prepared. Color (CIELab and CIEDE2000) was evaluated with a spectrophotometer after aging in grape juice (2 x 10 min/10mL/7days). The DC was analyzed by using Fourier transform infrared spectroscopy before and after light-curing. Data were statistically analyzed by using two-way analysis of variance and post-hoc least significant difference tests (p<0.05). In the color stability analysis, the interaction between filler type and opacity was significant (CIELab, p = 0.0015; CIEDE2000, p = 0.0026). NH presented the highest color stability, which did not differ from that of MH. The greatest color alteration was observed for S-PRG-NH. S-PRG fillers also influenced DC (p < 0.05). The nanohybrid resin composite presented favorable overall performance, which is likely related to its more stable organic content. Notwithstanding the benefits of using S-PRG-based nanohybrid resins, mostly in aesthetic procedures, professionals should consider the susceptibility of such resins to color alteration, probably due to the water-based bioactive mechanism of action.


  • Open Access

    Physical-mechanical properties of a flowable nanofiber-reinforced resin composite

    by Marilia Mattar de Amoêdo Campos Velo, Natália Almeida Bastos Bitencourt, Daniella Cristo Santin, Alyssa Teixeira Obeid, Rafael Francisco Lia Mondelli, Juliana Fraga Soares Bombonatti

    This in vitro study aimed to evaluate the effect of toothbrushing simulated test on wear and roughness of different low-viscosity resin composite, as well as the polymerization shrinkage stress. Thirty rectangular specimens (5 × 10 × 3 mm) were prepared and assigned into three different low-viscosity resin composites (n=10): Filtek flow Z350 (Z350); NanovaPro fill (Nanova), and SureFil SDR Flow (SDR). The specimens were brushed for 100.000 cycles using a toothbrushing testing machine with soft bristle tips (Colgate Classic, Colgate-Palmolive Co., Osasco, Sao Paulo, Brazil) and dentifrice suspension (Colgate MFP, Colgate-Palmolive Co.) in deionized water under a 300 g load. The surface roughness (Ra) (n=10) (before and after brushing) and wear (mm) (n=10) were measured by roughness tester. Also, the microhardness (KHN) (n=5) and shrinkage stress (MPa) (n=5) were evaluated. Data were analyzed by one-way for wear, microhardness and shrinkage stress data and two-way for roughness ANOVA and Tukey test (α = 0.05). The Nanova group presented higher final roughness (1.79±0.36) (p < 0.031), wear (13.87±3.26) (p <0.001) and microhardness (52.56±1.7) than the other groups (p < 0.006). For tensile test, all materials showed no difference in relation to shrinkage stress (p= 0.468). The Nanova group showed higher wear and roughness than the other groups. SDR and Z350 were statistically more resistant to wear.


  • Dental Cervical Lesions: How the Etiologies Imply in Different Approaches for Long-Lasting Performance

    by Giovanna Speranza Zabeu, Victor Mosquim, Natália Almeida Bastos-Bitencourt, Daniella Cristo Santin, Maria Angélica Silvério Agulhari, Linda Wang

    Particularities of dental cervical lesions require distinct approaches from preventive to therapeutic managements. Therefore, practitioners depend on their etiology, selected materials and patient involvement to provide conditions to effective performance. Through representative clinical scenarios, the main considerations regarding carious and non-carious cervical lesions (NCCL) are reported for the determination of strategies. Details regarding the disease, lesions aspects, evolution and involvement or not of the periodontal tissues are considered in their decision. In conclusion, their long-lasting resolution is determined by a complex combination of biomechanical factors and therapeutic strategies for each particular lesion, regardless of the cervical location solely.


  • Effect of thickness on shrinkage stress and bottom‐to‐top hardness ratio of conventional and bulk‐fill composites

    by Daniella Cristo Santin, Marilia Mattar de Amoêdo Campos Velo, Francielly da Silva Camim, Nair Cristina Margarido Brondino, Heitor Marques Honório, Rafael Francisco Lia Mondelli

    This study evaluated the effect of the material thickness on shrinkage stress and bottom‐to‐top hardness ratio of conventional and bulk‐fill composites. Six commercial composites were selected based on their different technologies: Two conventional (C1, C2), two high‐viscosity bulk‐fill (HVB1, HVB2), and two low‐viscosity bulk‐fill (LVB1, LVB2). Shrinkage stress was analyzed for five specimens with 2 mm thickness (C‐factor 0.75 and volume 24 mm3) and five specimens with 4 mm thickness (C‐factor 0.375 and volume 48 mm3) for 300 s in a universal testing machine. Bottom‐to‐top hardness ratio values were obtained from Knoop microhardness measurements in specimens with 2‐ and 4‐mm thickness (n = 5). Thickness increase resulted in significantly higher shrinkage stress for all materials with the exception of HVB2 and LVB1. C1, C2, HVB2, and LVB1 showed lower bottom‐to‐top hardness ratios at 4 mm than at 2 mm. Only LVB2 presented a bottom‐to‐top hardness ratio lower than 80% at 2 mm, while HVB1 surpassed this threshold at 4 mm of depth. The results suggest that the increase of composite thickness affected the shrinkage stress values. Also, thickness increase resulted in lower bottom‐to‐top hardness ratio. HVB1 showed better behavior than other bulk‐fill materials, with low stress and adequate bottom‐to‐top hardness ratio at 4 mm thickness.


  • Open Access

    Effect of sports drinks on the surface properties of composite resins after prolonged exposure

    by Daniella Cristo Santin, Fabiana Scarparo Naufel, Rafael Francisco Lia Mondelli, Adriano Piccolotto, Vera Lúcia Schmitt

    Aim: Using dietary supplements may affect the properties of composite resins due to their acidic pH. The present in vitro study aimed to assess the surface roughness and color stability of two composite resins - nanohybrid (Empress Direct) and nanoparticulate (Filtek Z350) - after prolonged exposure to dietary supplements. Methods: We produced 30 specimens from each composite (8x2-mm discs) and divided them into six groups (n=10). After the initial measurement of the surface properties (roughness and color), we exposed the specimens to a degradation process in Maltodextrin and Whey Protein for 22.5 and 7.5 days, respectively, using deionized water as the control solution. At the end of 22.5 days, we reassessed the specimens. After verifying data normality with the Kolmogorov-Smirnov test, we performed ANOVA followed by Tukey’s test at 5%. Results: We found significant differences for materials immersed in the Whey Protein solution (p3.3) after the immersion period (p<0.001). In Maltodextrin, the Empress Direct group presented (4.52+1.23) and Filtek Z350 (4.04+0.66), while after immersion in Whey Protein, they showed (5.34+1.68) and (4.26+1.02), respectively. Conclusion: Sports drinks changed the surface roughness and color stability of the composite resins studied. The Filtek Z350 group showed lower color variation than the Empress Direct composite in both solutions evaluated.


  • Open Access

    Evaluation of the effect of chlorhexidine and sodium hypochlorite in adhesive cementation of fiber posts - in vitro study

    by Tainara Conte, Guilherme Schmitt de Andrade, Ana Paula Gadonski, Daniella Cristo Santin, Fabiana Scarparo Naufel

    Introduction The attachment of fiberglass posts is achieved through an adhesive process. Failures in adhesion may occur due to the hydrolytic degradation of the adhesives, or to the degradation of the collagen fibres of the hybrid layer by intrinsic enzymes. Objective To evaluate the effect of chlorhexidine and sodium hypochlorite treatment on bond strength to dentin. Material and method Thirty bovine roots were randomly distributed into 3 groups (n=10): a) Control, b) 2% Chlorhexidine, and c) 5% Sodium Hypochlorite. Next, RelyX® ARC resin cement was used to cement the post. Each specimen resulted in samples from the three root thirds that were submitted to the pushout test (MPa) at 24 hours and 12 months. Bond strength values were analysed using the Kolmogorov-Smirnov, 3-way ANOVA and Tukey tests. The fracture mode of the pin was also analysed using stereomicroscopy. Result There were no significant differences between treatments at the immediate time (p=0.0644) or in the interaction of factors (p=0.1935). After one year, the experimental groups showed no significant differences in bond strength in relation to the control group, with the exception of the cervical third of the chlorohexidine group in which there was a significant loss of adhesion. As for the fracture mode, there was a predominance of the mixed type in all groups and thirds. Conclusion The use of chlorhexidine or hypochlorite provides neither benefits nor losses in the adhesive bond strength of fiberglass posts. However, there is an influence of the root thirds, with the worst bond strength in the apical third.


  • Open Access

    Avaliação do manchamento e da rugosidade superficial de materiais restauradores diretos após diferentes sistemas de polimento: estudo in vitro

    by Leonardo de Almeida, Daniella Cristo Santin, Bianca Medeiros Maran, Fabiana Scarparo Naufel, Vera Lúcia Schmitt

    Resumo Introdução Com o avanço estético e tecnológico dos compósitos restauradores diretos, a procura pela Odontologia Éstética tem aumentado. Objetivo Avaliar o manchamento e a rugosidade superficial dos compósitos Filtek Z350 (3M ESPE) e Filtek Bulk Fill (3M ESPE), polidos por diferentes sistemas: Disco SofLex e Disco SofLex diamantado espiral (ambos da 3M ESPE), após exposição repetitiva ao café. Material e método Neste estudo in vitro, um total de 80 discos de resina foi confeccionado, com 40 espécimes para cada compósito avaliado. Os espécimes foram ainda subdivididos em grupos (n=10) de acordo com o método de polimento ‒ SofLex e SofLex diamantado ‒ e a solução de armazenamento ‒ água deionizada (controle) e café (experimental). Após 24 horas de armazenamento em água deionizada, foi realizada a avaliação de cor e rugosidade inicial, bem como a execução dos protocolos de polimento testados. Posteriormente, os espécimes foram expostos ao processo de manchamento em café e água deionizada durante 42 dias. Após esse período, a cor e a rugosidade foram reavaliadas. Resultado A análise estatística paramétrica evidenciou que o manchamento superficial foi influenciado significativamente pelos fatores compósito e solução, mas não pelo fator polidor ou ainda por qualquer interação entre os fatores. Para o fator compósito, Filtek Z350 exibiu maior manchamento, e para o fator solução, foi observado maior manchamento para o café. Já na análise de rugosidade, não houve diferenças significativas. Conclusão Independentemente do sistema de polimento, a solução experimental de café alterou a cor de ambos os compósitos avaliados e verificou-se que a rugosidade não foi alterada.