Maria Angélica Silvério Agulhari
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Maria Angélica Silvério Agulhari has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Linda Wang
Department of Operative Dentistry, Endodontics and Dental Materials, Bauru School of Dentistry, University of São Paulo, Bauru, Brazil
3 shared publications - Daniella Cristo Santin
Department of Operative Dentistry, Endodontics and Dental Materials University of São Paulo‐USP, Bauru School of Dentistry Bauru SP Brazil
2 shared publications - Heitor Marques Honório
Department of Pediatric Dentistry, Orthodontics and Community Health, Bauru School of Dentistry, University of Sao Paulo, Sao Paulo, Brazil
2 shared publications - Victor Mosquim
Department of Operative Dentistry, Endodontics and Dental Materials, Bauru School of Dentistry, University of São Paulo, Bauru, Brazil
2 shared publications - Carolina Yoshi Campos Sugio
Universidade Federal de Uberlândia, Brasil
1 shared publication - Genine Moreira de Freitas Guimarães
University of São Paulo
1 shared publication
Latest Publications
- Open Access
- 1 January 2024
- Published by FapUNIFESP (SciELO) in Brazilian Oral Research
- Vol. 38, e003
Analysis of color stability and degree of conversion of different types of resin composites
Resin composites containing surface pre-reacted glass (S-PRG) have been introduced to reduce demineralization and improve remineralization of the tooth structure. However, water diffusion within the material is necessary for its action, which can impair its overall physicomechanical properties over time, including color stability. This study aimed to evaluate the color stability and related degree of conversion (DC) of four resin composites. Discs (6 x 4 mm, n = 5/group) of microhybrid (MH), nanofilled (NF), nanohybrid (NH), and S-PRG-based nanohybrid (S-PRG-NH) composites with two opacities (A2/A2E and A2O/A2D) were prepared. Color (CIELab and CIEDE2000) was evaluated with a spectrophotometer after aging in grape juice (2 x 10 min/10mL/7days). The DC was analyzed by using Fourier transform infrared spectroscopy before and after light-curing. Data were statistically analyzed by using two-way analysis of variance and post-hoc least significant difference tests (p<0.05). In the color stability analysis, the interaction between filler type and opacity was significant (CIELab, p = 0.0015; CIEDE2000, p = 0.0026). NH presented the highest color stability, which did not differ from that of MH. The greatest color alteration was observed for S-PRG-NH. S-PRG fillers also influenced DC (p < 0.05). The nanohybrid resin composite presented favorable overall performance, which is likely related to its more stable organic content. Notwithstanding the benefits of using S-PRG-based nanohybrid resins, mostly in aesthetic procedures, professionals should consider the susceptibility of such resins to color alteration, probably due to the water-based bioactive mechanism of action.
- 1 January 2024
- Published by FapUNIFESP (SciELO) in Brazilian Oral Research
- Vol. 38, e003
Open AccessAnalysis of color stability and degree of conversion of different types of resin composites
Resin composites containing surface pre-reacted glass (S-PRG) have been introduced to reduce demineralization and improve remineralization of the tooth structure. However, water diffusion within the material is necessary for its action, which can impair its overall physicomechanical properties over time, including color stability. This study aimed to evaluate the color stability and related degree of conversion (DC) of four resin composites. Discs (6 x 4 mm, n = 5/group) of microhybrid (MH), nanofilled (NF), nanohybrid (NH), and S-PRG-based nanohybrid (S-PRG-NH) composites with two opacities (A2/A2E and A2O/A2D) were prepared. Color (CIELab and CIEDE2000) was evaluated with a spectrophotometer after aging in grape juice (2 x 10 min/10mL/7days). The DC was analyzed by using Fourier transform infrared spectroscopy before and after light-curing. Data were statistically analyzed by using two-way analysis of variance and post-hoc least significant difference tests (p<0.05). In the color stability analysis, the interaction between filler type and opacity was significant (CIELab, p = 0.0015; CIEDE2000, p = 0.0026). NH presented the highest color stability, which did not differ from that of MH. The greatest color alteration was observed for S-PRG-NH. S-PRG fillers also influenced DC (p < 0.05). The nanohybrid resin composite presented favorable overall performance, which is likely related to its more stable organic content. Notwithstanding the benefits of using S-PRG-based nanohybrid resins, mostly in aesthetic procedures, professionals should consider the susceptibility of such resins to color alteration, probably due to the water-based bioactive mechanism of action.
- 16 May 2023
- Published by Taylor & Francis in Journal of Adhesion Science and Technology
- Vol. 37 (24) , 3569-3581
10-MDP-based dentin bonding systems: why is chlorhexidine not worth to be used adjunctively?
- 16 May 2023
- Published by Taylor & Francis in Journal of Adhesion Science and Technology
- Vol. 37 (24) , 3569-3581
10-MDP-based dentin bonding systems: why is chlorhexidine not worth to be used adjunctively?
- 27 January 2022
- Published by Archives of Health Investigation in ARCHIVES OF HEALTH INVESTIGATION
- Vol. 11 (1) , 125-133
Dental Cervical Lesions: How the Etiologies Imply in Different Approaches for Long-Lasting Performance
Particularities of dental cervical lesions require distinct approaches from preventive to therapeutic managements. Therefore, practitioners depend on their etiology, selected materials and patient involvement to provide conditions to effective performance. Through representative clinical scenarios, the main considerations regarding carious and non-carious cervical lesions (NCCL) are reported for the determination of strategies. Details regarding the disease, lesions aspects, evolution and involvement or not of the periodontal tissues are considered in their decision. In conclusion, their long-lasting resolution is determined by a complex combination of biomechanical factors and therapeutic strategies for each particular lesion, regardless of the cervical location solely.
- 27 January 2022
- Published by Archives of Health Investigation in ARCHIVES OF HEALTH INVESTIGATION
- Vol. 11 (1) , 125-133
Dental Cervical Lesions: How the Etiologies Imply in Different Approaches for Long-Lasting Performance
Particularities of dental cervical lesions require distinct approaches from preventive to therapeutic managements. Therefore, practitioners depend on their etiology, selected materials and patient involvement to provide conditions to effective performance. Through representative clinical scenarios, the main considerations regarding carious and non-carious cervical lesions (NCCL) are reported for the determination of strategies. Details regarding the disease, lesions aspects, evolution and involvement or not of the periodontal tissues are considered in their decision. In conclusion, their long-lasting resolution is determined by a complex combination of biomechanical factors and therapeutic strategies for each particular lesion, regardless of the cervical location solely.
- Open Access
- 8 February 2021
- Published by Instituto de Filosofia e Ciências Humanas - UNICAMP in Brazilian Journal of Oral Sciences
- Vol. 20, e219342
Dentin bond strength evaluation between a conventional and universal adhesive using etch-and-rinse strategy
Aim: The aim of this study was to compare the microtensile bond strength (μTBS) and the characteristics of the adhesive interface of Scotchbond Universal - SU – etch-and-rise mode (3M ESPE) and Adper Scotchbond Multi-Purpose - MP (3M ESPE) to dentin over time. Methods: Class I cavity preparations were performed in 60 human molars that were randomly divided according to the dentin bonding system (DBS) used (n=30): (1) Acid conditioning + SU and (2) Acid conditioning + MP. For bonding strength (BS) analysis, 30 teeth (n = 15) were sectioned into sticks and submitted to the microtensile test in a universal testing machine after 24 hours and 12 months. The adhesive interface of the others 30 teeth was analyzed in a confocal microscope after 24 hours and 12 months. The data of μTBS were analyzed by two-way repeated measures ANOVA and Tukey’s HSD (α = 0.05). Results: SU presented the lowest DBS compared to MP (p=0.000). Time did not influenced DBS for both adhesive systems (p=0.177). Confocal microscopy analysis showed no cracks between both adhesive systems tested. Conclusion: The results indicate that MP - μTBS showed a better performance compared to SU in total-etch mode.
- 8 February 2021
- Published by Instituto de Filosofia e Ciências Humanas - UNICAMP in Brazilian Journal of Oral Sciences
- Vol. 20, e219342
Open AccessDentin bond strength evaluation between a conventional and universal adhesive using etch-and-rinse strategy
Aim: The aim of this study was to compare the microtensile bond strength (μTBS) and the characteristics of the adhesive interface of Scotchbond Universal - SU – etch-and-rise mode (3M ESPE) and Adper Scotchbond Multi-Purpose - MP (3M ESPE) to dentin over time. Methods: Class I cavity preparations were performed in 60 human molars that were randomly divided according to the dentin bonding system (DBS) used (n=30): (1) Acid conditioning + SU and (2) Acid conditioning + MP. For bonding strength (BS) analysis, 30 teeth (n = 15) were sectioned into sticks and submitted to the microtensile test in a universal testing machine after 24 hours and 12 months. The adhesive interface of the others 30 teeth was analyzed in a confocal microscope after 24 hours and 12 months. The data of μTBS were analyzed by two-way repeated measures ANOVA and Tukey’s HSD (α = 0.05). Results: SU presented the lowest DBS compared to MP (p=0.000). Time did not influenced DBS for both adhesive systems (p=0.177). Confocal microscopy analysis showed no cracks between both adhesive systems tested. Conclusion: The results indicate that MP - μTBS showed a better performance compared to SU in total-etch mode.