Vera Lúcia Schmitt
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Vera Lúcia Schmitt has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Fabiana Scarparo Naufel
Universidade Estadual do Oeste do Paraná
6 shared publications - Adriano Piccolotto
Universidade Estadual do Oeste do Paraná
2 shared publications - Daniella Cristo Santin
Department of Operative Dentistry, Endodontics and Dental Materials University of São Paulo‐USP, Bauru School of Dentistry Bauru SP Brazil
2 shared publications - Leonardo de Almeida
Universidade Estadual do Oeste do Paraná
2 shared publications - Ana Paula Gadonski
Universidade Estadual de Campinas
1 shared publication - Anna Carolina Jaccottet Oliveira
Universidade Estadual do Oeste do Paraná
1 shared publication
Latest Publications
- Open Access
- 2 March 2021
- Published by Research, Society and Development in Research, Society and Development
- Vol. 10 (3)
A utilização do sistema CAD/CAM na resolução estética anterior de paciente com diferentes substratos
Atualmente na odontologia, existem tratamentos que aliam não só estética e longevidade, mas também facilidade na execução e consequentemente economia de tempo. O objetivo deste trabalho é demonstrar, através de um relato de caso clínico, a capacidade do sistema CAD/CAM CEREC (Ceramic Reconstruction) na mimetização da estrutura dental e padronização do substrato dental no resultado final. O presente estudo relata a confecção de restaurações anteriores (13, 12, 11, 21, 22 e 23) em dissilicato de lítio (E.max – Ivoclar vivadent), em uma paciente do gênero feminino, 50 anos, com diferentes substratos dentais, através de sistemas completos para consultório (chairside). Como resultados obteve-se: etapas clínicas alcançadas com sucesso, ótimas adaptações das peças, mimetização das estruturas dentais, resultando em restaurações cerâmicas de excelência, bem indicadas, confiáveis e esteticamente agradáveis, que foi o principal motivo pelo qual a paciente procurou atendimento.
- 2 March 2021
- Published by Research, Society and Development in Research, Society and Development
- Vol. 10 (3)
Open AccessA utilização do sistema CAD/CAM na resolução estética anterior de paciente com diferentes substratos
Atualmente na odontologia, existem tratamentos que aliam não só estética e longevidade, mas também facilidade na execução e consequentemente economia de tempo. O objetivo deste trabalho é demonstrar, através de um relato de caso clínico, a capacidade do sistema CAD/CAM CEREC (Ceramic Reconstruction) na mimetização da estrutura dental e padronização do substrato dental no resultado final. O presente estudo relata a confecção de restaurações anteriores (13, 12, 11, 21, 22 e 23) em dissilicato de lítio (E.max – Ivoclar vivadent), em uma paciente do gênero feminino, 50 anos, com diferentes substratos dentais, através de sistemas completos para consultório (chairside). Como resultados obteve-se: etapas clínicas alcançadas com sucesso, ótimas adaptações das peças, mimetização das estruturas dentais, resultando em restaurações cerâmicas de excelência, bem indicadas, confiáveis e esteticamente agradáveis, que foi o principal motivo pelo qual a paciente procurou atendimento.
- Open Access
- 1 January 2021
- Published by Research, Society and Development in Research, Society and Development
- Vol. 10 (1)
Reestabelecimento de guia canina com fragmentos cerâmicos em paciente bruxomano: Um relato de caso
Introdução: Atualmente é alto o índice de pacientes com sinais e sintomas de disfunções temporomandibulares, de etiologia multifatorial. Sendo o desgaste e apertamento dentário, as principais queixas caracterizadas pelo bruxismo. Além de afetar a estética, essa alteração é responsável pela modificação da oclusão do paciente, prejudicando a relação e distribuição de forças entre os dentes antagonistas. Sabe-se que, dentro do conceito de oclusão mutuamente protegida, os dentes anteriores estão aptos a receber forças oblíquas, enquanto os dentes posteriores recebem as verticais. Entretanto, com a ausência de guia canina, durante o movimento mandibular de lateralidade, os dentes posteriores apresentam contatos mal distribuídos, gerando forças oblíquas mastigatórias, resultando em desgastes e interferências comprometendo o sistema estomatognático. Objetivo: Descrever procedimentos executados em um paciente com histórico de bruxismo, devolvendo guia canina através da utilização de fragmentos cerâmicos E-max. Relato do caso clínico: Observou-se a ausência de guia canina, cujo tratamento de escolha foi o reestabelecimento das características anatômicas dos caninos com fragmentos confeccionados em cerâmica, ajuste oclusal e indicação posterior de uso contínuo de placa miorrelaxante em resina acrílica. Resultado Tratamento funcional com estética satisfatória e reestabelecimento da guia canina do paciente e sua oclusão mutuamente protegida. Conclusão: O tratamento relatado com fragmentos cerâmicos favoreceu os movimentos mandibulares excursivos e devolveu aspectos fisiológicos da oclusão, contribuindo na melhora dos sinais e sintomas do bruxismo e na qualidade de vida do paciente.
- 1 January 2021
- Published by Research, Society and Development in Research, Society and Development
- Vol. 10 (1)
Open AccessReestabelecimento de guia canina com fragmentos cerâmicos em paciente bruxomano: Um relato de caso
Introdução: Atualmente é alto o índice de pacientes com sinais e sintomas de disfunções temporomandibulares, de etiologia multifatorial. Sendo o desgaste e apertamento dentário, as principais queixas caracterizadas pelo bruxismo. Além de afetar a estética, essa alteração é responsável pela modificação da oclusão do paciente, prejudicando a relação e distribuição de forças entre os dentes antagonistas. Sabe-se que, dentro do conceito de oclusão mutuamente protegida, os dentes anteriores estão aptos a receber forças oblíquas, enquanto os dentes posteriores recebem as verticais. Entretanto, com a ausência de guia canina, durante o movimento mandibular de lateralidade, os dentes posteriores apresentam contatos mal distribuídos, gerando forças oblíquas mastigatórias, resultando em desgastes e interferências comprometendo o sistema estomatognático. Objetivo: Descrever procedimentos executados em um paciente com histórico de bruxismo, devolvendo guia canina através da utilização de fragmentos cerâmicos E-max. Relato do caso clínico: Observou-se a ausência de guia canina, cujo tratamento de escolha foi o reestabelecimento das características anatômicas dos caninos com fragmentos confeccionados em cerâmica, ajuste oclusal e indicação posterior de uso contínuo de placa miorrelaxante em resina acrílica. Resultado Tratamento funcional com estética satisfatória e reestabelecimento da guia canina do paciente e sua oclusão mutuamente protegida. Conclusão: O tratamento relatado com fragmentos cerâmicos favoreceu os movimentos mandibulares excursivos e devolveu aspectos fisiológicos da oclusão, contribuindo na melhora dos sinais e sintomas do bruxismo e na qualidade de vida do paciente.
- Open Access
- 12 November 2019
- Published by Instituto de Filosofia e Ciências Humanas - UNICAMP in Brazilian Journal of Oral Sciences
- Vol. 18, e191651
Effect of sports drinks on the surface properties of composite resins after prolonged exposure
Aim: Using dietary supplements may affect the properties of composite resins due to their acidic pH. The present in vitro study aimed to assess the surface roughness and color stability of two composite resins - nanohybrid (Empress Direct) and nanoparticulate (Filtek Z350) - after prolonged exposure to dietary supplements. Methods: We produced 30 specimens from each composite (8x2-mm discs) and divided them into six groups (n=10). After the initial measurement of the surface properties (roughness and color), we exposed the specimens to a degradation process in Maltodextrin and Whey Protein for 22.5 and 7.5 days, respectively, using deionized water as the control solution. At the end of 22.5 days, we reassessed the specimens. After verifying data normality with the Kolmogorov-Smirnov test, we performed ANOVA followed by Tukey’s test at 5%. Results: We found significant differences for materials immersed in the Whey Protein solution (p3.3) after the immersion period (p<0.001). In Maltodextrin, the Empress Direct group presented (4.52+1.23) and Filtek Z350 (4.04+0.66), while after immersion in Whey Protein, they showed (5.34+1.68) and (4.26+1.02), respectively. Conclusion: Sports drinks changed the surface roughness and color stability of the composite resins studied. The Filtek Z350 group showed lower color variation than the Empress Direct composite in both solutions evaluated.
- 12 November 2019
- Published by Instituto de Filosofia e Ciências Humanas - UNICAMP in Brazilian Journal of Oral Sciences
- Vol. 18, e191651
Open AccessEffect of sports drinks on the surface properties of composite resins after prolonged exposure
Aim: Using dietary supplements may affect the properties of composite resins due to their acidic pH. The present in vitro study aimed to assess the surface roughness and color stability of two composite resins - nanohybrid (Empress Direct) and nanoparticulate (Filtek Z350) - after prolonged exposure to dietary supplements. Methods: We produced 30 specimens from each composite (8x2-mm discs) and divided them into six groups (n=10). After the initial measurement of the surface properties (roughness and color), we exposed the specimens to a degradation process in Maltodextrin and Whey Protein for 22.5 and 7.5 days, respectively, using deionized water as the control solution. At the end of 22.5 days, we reassessed the specimens. After verifying data normality with the Kolmogorov-Smirnov test, we performed ANOVA followed by Tukey’s test at 5%. Results: We found significant differences for materials immersed in the Whey Protein solution (p3.3) after the immersion period (p<0.001). In Maltodextrin, the Empress Direct group presented (4.52+1.23) and Filtek Z350 (4.04+0.66), while after immersion in Whey Protein, they showed (5.34+1.68) and (4.26+1.02), respectively. Conclusion: Sports drinks changed the surface roughness and color stability of the composite resins studied. The Filtek Z350 group showed lower color variation than the Empress Direct composite in both solutions evaluated.
- Open Access
- 31 October 2019
- Published by Editora Cubo in Brazilian Dental Science
- Vol. 22 (4) , 488-496
Bond strength to ZLS ceramics at different etching times and cementation protocols after aging
Objective: To assess the influence of 5% hydrofluoric acid etching time (ET), cementation protocol (CP), and thermal cycling (TC) aging on the microshear bond strength (µSBS) of zirconia-reinforced lithium silicate ceramic (ZLS) to adhesive resin cement. Material and Methods: Ten VITA Suprinity® ceramic blocks were cut in 120 slices (1.4 mm thickness) and randomly assigned to 12 groups (n = 10) according to the combination of factors (2x3x2 design): etching time (20 or 30 s), cementation protocol (silane + universal adhesive + resin cement; universal adhesive + resin cement; silane + resin cement) and thermal cycling (cycled or no-cycled). RelyX Ceramic Primer and Scotchbond™ Universal Adhesive were used respectively as silane (S) and universal adhesive (Ua). Ceramic surface was etched, and the cementation protocol performed on the delimited bonding area. Then, resin cement (RelyX™ Ultimate Cement [Rc]) cylinders were bonded and light cured. After, specimens were stored in deionized water at 37°C for 7 days and subjected to the µSBS test. Results: Data passed the normality test and three-way ANOVA analysis showed statistical difference (p<0.01) for isolated; double (ET/TC) (p<0.05), and triple (p<0.05) factor interactions. Conclusion: The combination 30s etching-Ua-Rc presented higher adhesive bond strength after thermal aging.
- 31 October 2019
- Published by Editora Cubo in Brazilian Dental Science
- Vol. 22 (4) , 488-496
Open AccessBond strength to ZLS ceramics at different etching times and cementation protocols after aging
Objective: To assess the influence of 5% hydrofluoric acid etching time (ET), cementation protocol (CP), and thermal cycling (TC) aging on the microshear bond strength (µSBS) of zirconia-reinforced lithium silicate ceramic (ZLS) to adhesive resin cement. Material and Methods: Ten VITA Suprinity® ceramic blocks were cut in 120 slices (1.4 mm thickness) and randomly assigned to 12 groups (n = 10) according to the combination of factors (2x3x2 design): etching time (20 or 30 s), cementation protocol (silane + universal adhesive + resin cement; universal adhesive + resin cement; silane + resin cement) and thermal cycling (cycled or no-cycled). RelyX Ceramic Primer and Scotchbond™ Universal Adhesive were used respectively as silane (S) and universal adhesive (Ua). Ceramic surface was etched, and the cementation protocol performed on the delimited bonding area. Then, resin cement (RelyX™ Ultimate Cement [Rc]) cylinders were bonded and light cured. After, specimens were stored in deionized water at 37°C for 7 days and subjected to the µSBS test. Results: Data passed the normality test and three-way ANOVA analysis showed statistical difference (p<0.01) for isolated; double (ET/TC) (p<0.05), and triple (p<0.05) factor interactions. Conclusion: The combination 30s etching-Ua-Rc presented higher adhesive bond strength after thermal aging.
- Open Access
- 1 January 2019
- Published by FapUNIFESP (SciELO) in Revista de Odontologia da UNESP
- Vol. 48
Bond strength assessment of a universal adhesive system in etch-and-rinse and self-etch modes
Introduction Modern dentistry is reflected in the insertion of new materials with different adhesion forms in dental structures, such as the Universal adhesive system. Objective To evaluate the bond strength of the universal dentin adhesive system, in the form of self-etching and conventional application, compared with a simplified conventional adhesive system, in two distinct periods: 1 week and 6 months. Material and method 48 bovine incisors separated into 6 groups, stored for 7 days, were selected. Worn out the buccal enamel until dentin exposure. Adper Single Bond 2 (3M Espe) or SingleBond Universal (3M Espe) adhesives were applied, and catheters filled with Opallis Flow (FGM) composite were placed. After photoactivation, the catheters were removed and the specimens (n = 48), stored in distilled water at 37 °C for one week and six months, were exposed. The specimens were fixed to a universal testing machine (EMIC DL 2000) with a speed of 0.5 mm / min. Bond strength (BS) was calculated in MPa, and data were statistically analyzed by Anova and Tukey test at 5% significance level. Result For Adper Single bond, the BS was equivalent in the times tested; for Universal conventional and self-conditioning time influenced the BS, with a decrease in the results. At 1 week, all stickers were different from each other, with higher BS for Universal conventional mode, followed by universal self-etching mode and then Adper Single bond. Conclusion The best results were achieved with universal adhesive in conventional mode for both tested times.
- 1 January 2019
- Published by FapUNIFESP (SciELO) in Revista de Odontologia da UNESP
- Vol. 48
Open AccessBond strength assessment of a universal adhesive system in etch-and-rinse and self-etch modes
Introduction Modern dentistry is reflected in the insertion of new materials with different adhesion forms in dental structures, such as the Universal adhesive system. Objective To evaluate the bond strength of the universal dentin adhesive system, in the form of self-etching and conventional application, compared with a simplified conventional adhesive system, in two distinct periods: 1 week and 6 months. Material and method 48 bovine incisors separated into 6 groups, stored for 7 days, were selected. Worn out the buccal enamel until dentin exposure. Adper Single Bond 2 (3M Espe) or SingleBond Universal (3M Espe) adhesives were applied, and catheters filled with Opallis Flow (FGM) composite were placed. After photoactivation, the catheters were removed and the specimens (n = 48), stored in distilled water at 37 °C for one week and six months, were exposed. The specimens were fixed to a universal testing machine (EMIC DL 2000) with a speed of 0.5 mm / min. Bond strength (BS) was calculated in MPa, and data were statistically analyzed by Anova and Tukey test at 5% significance level. Result For Adper Single bond, the BS was equivalent in the times tested; for Universal conventional and self-conditioning time influenced the BS, with a decrease in the results. At 1 week, all stickers were different from each other, with higher BS for Universal conventional mode, followed by universal self-etching mode and then Adper Single bond. Conclusion The best results were achieved with universal adhesive in conventional mode for both tested times.
- Open Access
- 1 January 2019
- Published by FapUNIFESP (SciELO) in Revista de Odontologia da UNESP
- Vol. 48
Avaliação do manchamento e da rugosidade superficial de materiais restauradores diretos após diferentes sistemas de polimento: estudo in vitro
Resumo Introdução Com o avanço estético e tecnológico dos compósitos restauradores diretos, a procura pela Odontologia Éstética tem aumentado. Objetivo Avaliar o manchamento e a rugosidade superficial dos compósitos Filtek Z350 (3M ESPE) e Filtek Bulk Fill (3M ESPE), polidos por diferentes sistemas: Disco SofLex e Disco SofLex diamantado espiral (ambos da 3M ESPE), após exposição repetitiva ao café. Material e método Neste estudo in vitro, um total de 80 discos de resina foi confeccionado, com 40 espécimes para cada compósito avaliado. Os espécimes foram ainda subdivididos em grupos (n=10) de acordo com o método de polimento ‒ SofLex e SofLex diamantado ‒ e a solução de armazenamento ‒ água deionizada (controle) e café (experimental). Após 24 horas de armazenamento em água deionizada, foi realizada a avaliação de cor e rugosidade inicial, bem como a execução dos protocolos de polimento testados. Posteriormente, os espécimes foram expostos ao processo de manchamento em café e água deionizada durante 42 dias. Após esse período, a cor e a rugosidade foram reavaliadas. Resultado A análise estatística paramétrica evidenciou que o manchamento superficial foi influenciado significativamente pelos fatores compósito e solução, mas não pelo fator polidor ou ainda por qualquer interação entre os fatores. Para o fator compósito, Filtek Z350 exibiu maior manchamento, e para o fator solução, foi observado maior manchamento para o café. Já na análise de rugosidade, não houve diferenças significativas. Conclusão Independentemente do sistema de polimento, a solução experimental de café alterou a cor de ambos os compósitos avaliados e verificou-se que a rugosidade não foi alterada.
- 1 January 2019
- Published by FapUNIFESP (SciELO) in Revista de Odontologia da UNESP
- Vol. 48
Open AccessAvaliação do manchamento e da rugosidade superficial de materiais restauradores diretos após diferentes sistemas de polimento: estudo in vitro
Resumo Introdução Com o avanço estético e tecnológico dos compósitos restauradores diretos, a procura pela Odontologia Éstética tem aumentado. Objetivo Avaliar o manchamento e a rugosidade superficial dos compósitos Filtek Z350 (3M ESPE) e Filtek Bulk Fill (3M ESPE), polidos por diferentes sistemas: Disco SofLex e Disco SofLex diamantado espiral (ambos da 3M ESPE), após exposição repetitiva ao café. Material e método Neste estudo in vitro, um total de 80 discos de resina foi confeccionado, com 40 espécimes para cada compósito avaliado. Os espécimes foram ainda subdivididos em grupos (n=10) de acordo com o método de polimento ‒ SofLex e SofLex diamantado ‒ e a solução de armazenamento ‒ água deionizada (controle) e café (experimental). Após 24 horas de armazenamento em água deionizada, foi realizada a avaliação de cor e rugosidade inicial, bem como a execução dos protocolos de polimento testados. Posteriormente, os espécimes foram expostos ao processo de manchamento em café e água deionizada durante 42 dias. Após esse período, a cor e a rugosidade foram reavaliadas. Resultado A análise estatística paramétrica evidenciou que o manchamento superficial foi influenciado significativamente pelos fatores compósito e solução, mas não pelo fator polidor ou ainda por qualquer interação entre os fatores. Para o fator compósito, Filtek Z350 exibiu maior manchamento, e para o fator solução, foi observado maior manchamento para o café. Já na análise de rugosidade, não houve diferenças significativas. Conclusão Independentemente do sistema de polimento, a solução experimental de café alterou a cor de ambos os compósitos avaliados e verificou-se que a rugosidade não foi alterada.