JLJinsong Li

Jinsong Li

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Jinsong Li has a total of 41 co-authors. Here are the top co-authors by number of shared publications:

  • Jie Wang

    7 shared publications
  • Na Li

    7 shared publications
  • Wenhui Yang

    State Key Laboratory of Pathogen and Biosecurity, Beijing Institute of Microbiology and Epidemiology, Academy of Military and Medical Sciences, Beijing 100071, P.R. China

    5 shared publications
  • Zhanbo Wen

    State Key Laboratory of Pathogen and Biosecurity, Beijing Institute of Microbiology and Epidemiology, Academy of Military and Medical Sciences, Beijing 100071, P.R. China

    5 shared publications
  • Long Yu

    State Key Laboratory of Pathogen and Biosecurity, Beijing Institute of Microbiology and Epidemiology, Fengtai District, Beijing, China

    4 shared publications
  • Jianchun Lu

    State Research Center for Bioprotective Equipment and Engineering Technology, State Key Laboratory of Pathogen and Biosecurity, Beijing Institute of Microbiology and Epidemiology, Beijing, People's Republic of China

    3 shared publications

Latest Publications

  • Open Access

    Influence of fine particulate matter and its pure particulate fractions on pulmonary immune cells and cytokines in mice

    by Zhouguang Jiao, Zhanbo Wen, Wenhui Yang, Lingfei Hu, Jinsong Li

    Particulate matter with a diameter <= 2.5 mu m (PM2.5) has a complex composition and has been associated with the incidence of cardiopulmonary disease and premature death in humans. However, whether pure particulate fractions of PM2.5 (PPP2.5), which are composed primarily of carbon, are responsible for the toxicity caused by ambient particulate matter (original PM2.5 particles, OPP2.5) is currently unclear. The present study assessed the acute toxic effects of OPP2.5 sampled in Beijing, China and of its PPP2.5 fraction in male BALB/c mice. The mice were intratracheally instilled with a single dose of aerosolized OPP2.5 or PPP2.5. Blood, lungs and bronchoalveolar lavage fluid were collected after 24 h for histopathology, flow cytometry and the measurement of pro-inflammatory cytokines/chemokines and other biochemical factors. Both OPP2.5 and PPP2.5 caused acute toxicity, particularly inflammatory responses, including an increase in the levels of pro-inflammatory cytokines and an accumulation of numerous immune cells in the lungs. OPP2.5 induced a stronger inflammatory response than PPP2.5. The complex components adsorbed into the solid core granules of OPP2.5 and the granules themselves contributed to the toxic effects.


  • Orthogonal optimization design of structural parameters for bioaerosol sampler using computational fluid dynamics simulation and field experiments

    by Xuezheng Ma, Zhijian Liu, Fanshaung Li, Yu Niu, Beibei Wang, Huipeng Li, Haiyang Liu, Rui Rong, Guoyan Wang, Liping Zhang, et al.

    Aerosol-to-hydrosol biological samplers have a low particle collection rate and aerosol-to-liquid efficiency owing to their airflow rate and geometry. The study develops a method to optimize the design of an aerosol-to-hydrosol bioaerosol sampler for better particle-collection efficiency. Four important performance parameters-particle size, nozzle angle, liquid container shape, and distance between nozzle and liquid surface-were optimized using the orthogonal design method. These parameters, along with the particle-capturing characteristics, were predicted using an approach based on computational fluid dynamics. Subsequently, this approach was used to test the bioaerosol's capture efficiency. A prototype based on the optimized geometrical design was 3D-printed and tested in a field experiment. The most optimal parameters were particle size = 10 mu m; inverted cone shape; liquid-level-nozzle distance = 10 mm; and angle = 45 degrees. Copyright (c) 2020 American Association for Aerosol Research


  • Assessment the protection performance of different level personal respiratory protection masks against viral aerosol

    by ZhanBo Wen, Long Yu, WenHui Yang, LingFei Hu, Na Li, Jie Wang, JinSong Li, JianChun Lu, XiaoKai Dong, Zhe Yin, et al.

    New viral disease such as SARS and H1N1 highlighted the vulnerability of healthcare workers to aerosol-transmitted viral infections. This paper was to assess the protection performance of different level personal respiratory protection equipments against viral aerosol. Surgical masks, N95 masks and N99 masks were purchased from the market. The masks were sealed onto the manikin in the aerosol testing chamber. Viral aerosol was generated and then sampled simultaneously before and after the tested mask using biosamplers. This allows a percentage efficiency value to be calculated against test phage SM702 aerosols which surrogates of viral pathogens aerosol. At the same time, the masks face fit factor was determined by TSI8020. The viral aerosol particles aerodynamic diameter was 0.744 μm, and GSD was 1.29. The protection performance of the material of all the tested masks against viral aerosol was all >95 %. All the five surgical masks face fit factor were 160. G model N95 mask face fit factor was 8.2. The protection performances of N95 or N99 masks were many times higher than surgical mask when considering the face fit factor. Surgical masks cannot offer sufficient protection against the inhalation of viral aerosol because they cannot provide a close face seal.


  • Open Access

    Aerosolized avian influenza virus by laboratory manipulations

    by Zhiping Li, Jinsong Li, Yandong Zhang, Lin Li, Limin Ma, Dan Li, Feng Gao, Zhiping Xia

    Background: Avian H5N1 influenza viruses present a challenge in the laboratory environment, as they are difficult to collect from the air due to their small size and relatively low concentration. In an effort to generate effective methods of H5N1 air removal and ensure the safety of laboratory personnel, this study was designed to investigate the characteristics of aerosolized H5N1 produced by laboratory manipulations during research studies. Results: Normal laboratory procedures used to process the influenza virus were carried out independently and the amount of virus polluting the on-site atmosphere was measured. In particular, zootomy, grinding, centrifugation, pipetting, magnetic stirring, egg inoculation, and experimental zoogenetic infection were performed. In addition, common accidents associated with each process were simulated, including breaking glass containers, syringe injection of influenza virus solution, and rupturing of centrifuge tubes. A micro-cluster sampling ambient air pollution collection device was used to collect air samples. The collected viruses were tested for activity by measuring their ability to induce hemagglutination with chicken red blood cells and to propagate in chicken embryos after direct inoculation, the latter being detected by reverse-transcription PCR and HA test. The results showed that the air samples from the normal centrifugal group and the negative-control group were negative, while all other groups were positive for H5N1. Conclusions: Our findings suggest that there are numerous sources of aerosols in laboratory operations involving H5N1. Thus, laboratory personnel should be aware of the exposure risk that accompanies routine procedures involved in H5N1 processing and take proactive measures to prevent accidental infection and decrease the risk of virus aerosol leakage beyond the laboratory.


  • Open Access

    Study on the Testing Method to Determine the Performance of Personal Respiratory Protection Equipment against a Viral Aerosol

    by ZhanBo Wen, Na Li, JinSong Li, Jie Wang, JianJun Zhao, WenHui Yang, LingFei Hu, XiaoKai Dong, JianCHun Lu

    Respiratory illnesses are increasingly recognized as a growing concern for healthcare workers (HCWs) and patients. The 2003 hospital-based outbreak of Severe Acute Respiratory Syndrome (SARS) has once again highlighted the vulnerability of HCWs to aerosol-transmitted viral infections. Personal respiratory protective equipment was one of the key means for the HCWs to avoid nosocomial transmission of the virus. This article studied a testing method for determining the performance of personal respiratory protection equipment against a viral aerosol. Full-mask respirators with HEPA filters were selected for this study. Phage f2 was used as a surrogate for a viral pathogen. A viral aerosol was generated and then sampled in front of and behind the test respirators, allowing a percentage efficiency value to be calculated against viral aerosols. HEPA-filtered respirators demonstrated a high filtration efficiency of >99.99% and can protect the wearers against the viral aerosol transmission. This test methodology can be used to assess the filtration efficacy of personal respiratory protection equipment against a viral aerosol.


  • Impact of Relative Humidity and Collection Media on Mycobacteriophage D29 Aerosol

    by Keyang Liu, Zhanbo Wen, Na Li, Wenhui Yang, Jie Wang, Lingfei Hu, Xiaokai Dong, Jianchun Lu, Jinsong Li

    This study was conducted to evaluate the effect of aerosol generation, methods of sampling, storage conditions, and relative humidity on the culturability of the mycobacteriophage D29. The lytic phage D29 can kill Mycobacterium tuberculosis , and the phage aerosol can be treated as a potential tool for tuberculosis treatment. The culturability of D29 was tested using a test chamber designed for the bioaerosols research against three spray liquids (deionized water, phosphate-buffered saline [PBS], and normal saline), four collection media (suspension medium [SM], nutrient broth, PBS, and deionized water), two sampling systems (the all-glass impinger AGI-30 and the Biosampler) and across a range of humidities (20 to 90%). The effect of storage conditions on the culturability of collected sample was also evaluated for the AGI-30 impinger. The results proved that viable phage D29 particles generated by deionized water were approximately 30- and 300-fold higher than PBS and normal saline, respectively. As collection media, SM buffer and nutrient broth were observed to yield a higher number of plaques compared to PBS and deionized water. No difference was observed in collection efficiency between AGI-30 and Biosampler with two detection methods (culture-based technique and real-time PCR). The culturability of collected D29 in SM buffer or nutrient broth can be maintained up to 12 h irrespective of storage temperature. Relative humidity was found to strongly influence airborne D29 culturability which is 2- to 20-fold higher in low humidity (25%) than medium (55%) or high (85%) humidity. This research will help identify the optimal means for the application of D29 aerosol in animal inhalation experiments.


    • 1 May 2011
      • Vol. 32  (5) , 460-4

    [Studies on key technique, production, law and criterion of laboratory biosafety in China].

    by Jin-Song Li, Nai-Yuan Zhou

  • Determining the filtration efficiency of half-face medical protection mask (N99) against viral aerosol

    by ZhanBo Wen, JianChun Lu, JinSong Li, Na Li, JianJun Zhao, Jie Wang, Long Yu, WenHui Yang

    Hospital-based outbreaks of severe acute respiratory syndrome (SARS) have once again highlighted the vulnerability of healthcare workers (HCWs). Use of personal respiratory protective equipment was the main method used by HCWs to avoid nosocomial transmission. This paper describes the technology used to evaluate the filtration efficiency of the half-face medical protection mask (N99), manufactured by Firmshield Biotechnology, against viral aerosol. Viral aerosol was generated and then sampled simultaneously with and without the test mask. This enables a percentage efficiency value to be calculated against test phage f2 aerosols (surrogates of viral pathogen aerosols). At the same time the mask filtration efficiency against NaCl particle aerosol was determined by use of TSI8130 equipment and face-fit factor was tested by use of TSI8020 equipment. The half-face medical protection mask (N99) evaluated by use of the viral aerosol had a filtration efficiency >99%. The mask filtration efficiency against NaCl particle aerosol was 99.634 ± 0.024% and it had a good face-fit factor. This half-face medical protection mask (N99) can protect the wearer from viral aerosol disease transmission. The test method can be used to assess filtration efficacy against viral aerosol of masks used for respiratory protection.


  • Effects of different sampling solutions on the survival of bacteriophages in bubbling aeration

    by Long Yu, Zhanbo Wen, Jinsong Li, Wenhui Yang, Jie Wang, Na Li, Jianchun Lu

    The present study focuses on the effects of three different sampling solutions, namely distilled water, phosphatic buffer solution, and suspension medium (SM), adding antifoam or not, on the survival probability of several different bacteriophages (EcP1,PhiX174,SM702, and F2) as surrogates for the mammalian viruses in the bubbling process. AGI-10 impinger was used as the representative for all the impingers which would bubble during operation. It was found that the survival probability of the same bacteriophage bubbling with different sampling solutions was different except that there was no significant difference observed for the bacteriophage F2. The use of SM as the collection fluid was relative to a high survival probability for the four bacteriophages. And the endurance or resistance of different kinds of bacteriophages in the same sampling solution was different. We conclude that SM is a promising sampling solution for liquid impingers in the process of sampling phages.