Lakshminarayan Ravichandran
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Lakshminarayan Ravichandran has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
- Carson A. Wick
School of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, 30332 USA
2 shared publications - Srini Tridandapani
Department of Radiology and Imaging Sciences, Emory University, Atlanta, GA, USA
2 shared publications - James H. McClellan
School of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, GA, USA
1 shared publication
Latest Publications
- 1 August 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Annual International Conference of the IEEE Engineering in Medicine and Biology Society
- Vol. 2012 (1094687X) , 4071-4074
An active contour based method for analyzing cardiac quiescence from echocardiography
A semi-automated method for analyzing cardiac quiescence of anatomical cardiac features from two-dimensional echocardiographic cine data is presented. The method utilizes both active contour and optical flow techniques for feature identification and tracking. A curvature-based potential surface was used in the active contour calculations to attract the contour to regions of inflection on the image surface rather than the standard gradient-based surface that attracts the contour to strong edges. After identifying the feature in each frame, the frame-to-frame correlation matrix of the feature was calculated with correlation values corresponding to how well the feature matched between frames. Therefore prolonged regions of high correlation correspond to periods of cardiac quiescence. The location and duration of these periods were automatically identified from the correlation matrix by finding the largest region around each time index with a mean correlation above a specified threshold. In parallel, the position of the feature was calculated for each frame by finding the centroid of the pixel locations inside the contour. From this trajectory, the magnitude of the two-dimensional velocity was calculated. These methods were used to analyze the quiescence of the interventricular septum from an apical four-chamber echocardiogram performed on a human subject. Correlation-derived quiescent phases were observed to coincide with periods of the cardiac cycle with minimal velocity magnitude.
- 1 August 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Annual International Conference of the IEEE Engineering in Medicine and Biology Society
- Vol. 2012 (1094687X) , 4071-4074
An active contour based method for analyzing cardiac quiescence from echocardiography
A semi-automated method for analyzing cardiac quiescence of anatomical cardiac features from two-dimensional echocardiographic cine data is presented. The method utilizes both active contour and optical flow techniques for feature identification and tracking. A curvature-based potential surface was used in the active contour calculations to attract the contour to regions of inflection on the image surface rather than the standard gradient-based surface that attracts the contour to strong edges. After identifying the feature in each frame, the frame-to-frame correlation matrix of the feature was calculated with correlation values corresponding to how well the feature matched between frames. Therefore prolonged regions of high correlation correspond to periods of cardiac quiescence. The location and duration of these periods were automatically identified from the correlation matrix by finding the largest region around each time index with a mean correlation above a specified threshold. In parallel, the position of the feature was calculated for each frame by finding the centroid of the pixel locations inside the contour. From this trajectory, the magnitude of the two-dimensional velocity was calculated. These methods were used to analyze the quiescence of the interventricular septum from an apical four-chamber echocardiogram performed on a human subject. Correlation-derived quiescent phases were observed to coincide with periods of the cardiac cycle with minimal velocity magnitude.
- Open Access
- 1 August 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Annual International Conference of the IEEE Engineering in Medicine and Biology Society
- Vol. 2012 (1094687X) , 1562-1565
Detection of quiescent phases in echocardiography data using non-linear filtering and boundary detection
In order to detect the quasi-stationary states of the heart within a cardiac cycle from echocardiography data, we present an algorithm that uses non-linear filtering and boundary detection. The non-linear filtering algorithm involves anisotropic diffusion to remove the speckle noise from the data and to smoothen the homogeneous regions while preserving the edges. Following this, we perform binary thresholding and boundary detection, and observe the positional changes in the region of interest. From a series of echocardiography images, we derived the regions of cardiac quiescence, which we then plotted on the electrocardiograph (ECG) R-R interval. It is observed that the quiescence occurs in the diastolic region of the ECG signal, but the position and length of quiescence varies across multiple cardiac cycles for the same individual.
- 1 August 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Annual International Conference of the IEEE Engineering in Medicine and Biology Society
- Vol. 2012 (1094687X) , 1562-1565
Open AccessDetection of quiescent phases in echocardiography data using non-linear filtering and boundary detection
In order to detect the quasi-stationary states of the heart within a cardiac cycle from echocardiography data, we present an algorithm that uses non-linear filtering and boundary detection. The non-linear filtering algorithm involves anisotropic diffusion to remove the speckle noise from the data and to smoothen the homogeneous regions while preserving the edges. Following this, we perform binary thresholding and boundary detection, and observe the positional changes in the region of interest. From a series of echocardiography images, we derived the regions of cardiac quiescence, which we then plotted on the electrocardiograph (ECG) R-R interval. It is observed that the quiescence occurs in the diastolic region of the ECG signal, but the position and length of quiescence varies across multiple cardiac cycles for the same individual.