MSManojkumar Saranathan

Manojkumar Saranathan

*This is an algorithmically generated author record based on publicly available information.

Manojkumar Saranathan has a total of 27 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Variable spatiotemporal resolution three‐dimensional dixon sequence for rapid dynamic contrast‐enhanced breast MRI

    by Manojkumar Saranathan, Dan W. Rettmann, Brian A. Hargreaves, Jafi A. Lipson, Bruce L. Daniel

    Purpose: To investigate a new variable spatiotemporal resolution dynamic contrast‐enhanced (DCE) MRI method termed DIfferential Subsampling with Cartesian Ordering (DISCO), for imaging of breast cancer.Materials and Methods: DISCO combines variable density, pseudorandom k‐space segmentation and two‐point Dixon fat–water separation for high spatiotemporal resolution breast DCE MRI. During the contrast wash‐in phase, view sharing is used to achieve high temporal resolution. Forty patients referred for breast MRI were imaged, 26 using the proposed DISCO sequence and 14 using a conventional low‐spatial‐resolution dynamic sequence (VIBRANT‐FLEX) on a 3 Tesla scanner. DISCO dynamic images from 14 patients were compared with VIBRANT‐FLEX images from 14 other patients. The image quality assessed by radiologist image ranking in a blinded manner, and the temporal characteristics of the two sequences were compared.Results: A spatial resolution of 1.1 × 1.1 × 1.2 mm3 (160 slices, 28 cm field of view) was achieved with axial bilateral coverage in 120 s. Dynamic images with ∼9 s effective temporal resolution were generated during the 2‐min contrast wash‐in phase. The image quality of DISCO dynamic images ranked significantly higher than low spatial resolution VIBRANT‐FLEX images (19.5 versus 9.5, Mann‐Whitney U‐test P = 0.00914), with no significant differences in the maximum slope of aortic enhancement.Conclusion: DISCO is a promising variable‐spatiotemporal‐resolution imaging sequence for capturing the dynamics of rapidly enhancing tumors as well as structural features postcontrast. A near 1‐mm isotropic spatial resolution was achieved with postcontrast static phase images in 120 s and dynamic phase images acquired in 9 s per phase. J. Magn. Reson. Imaging 2014;40:1392–1399. © 2013 Wiley Periodicals, Inc.

  • Open Access

    Optimization of white-matter-nulled magnetization prepared rapid gradient echo (MP-RAGE) imaging

    by Manojkumar Saranathan, Thomas Tourdias, Ersin Bayram, Pejman Ghanouni, Brian K. Rutt

    Purpose To optimize the white‐matter‐nulled (WMn) Magnetization Prepared Rapid Gradient Echo (MP‐RAGE) sequence at 7 Tesla (T), with comparisons to 3T. Methods Optimal parameters for maximizing signal‐to‐noise ratio (SNR) efficiency were derived. The effect of flip angle and repetition time (TR) on image blurring was modeled using simulations and validated in vivo. A novel two‐dimensional (2D) ‐centric radial fan beam (RFB) k‐space segmentation scheme was used to shorten scan times and improve parallel imaging. Healthy subjects as well as patients with multiple sclerosis and tremor were scanned using the optimized protocols. Results Inversion repetition times (TS) of 4.5 s and 6 s were found to yield the highest SNR efficiency for WMn MP‐RAGE at 3T and 7T, respectively. Blurring was more sensitive to flip in WMn than in CSFn MP‐RAGE and relatively insensitive to TR for both regimes. The 2D RFB scheme had 19% and 47% higher thalamic SNR and SNR efficiency than the 1D centric scheme for WMn MP‐RAGE. Compared with 3T, SNR and SNR efficiency were higher for the 7T WMn regime by 56% and 41%, respectively. MS lesions in the cortex and thalamus as well as thalamic subnuclei in tremor patients were clearly delineated using WMn MP‐RAGE. Conclusion Optimization and new view ordering enabled MP‐RAGE imaging with 0.8–1 mm3 isotropic spatial resolution in scan times of 5 min with whole brain coverage. Magn Reson Med 73:1786–1794, 2015.


  • Optimization of Magnetization-Prepared 3-Dimensional Fluid Attenuated Inversion Recovery Imaging for Lesion Detection at 7 T

    by Manojkumar Saranathan, Thomas Tourdias, Adam B. Kerr, Jeff D. Bs Bernstein, Geoffrey A. Kerchner, May H. Han, Brian K. Rutt

    Purpose The aim of this study was to optimize the 3-dimensional (3D) fluid attenuated inversion recovery (FLAIR) pulse sequence for isotropic high-spatial-resolution imaging of white matter (WM) and cortical lesions at 7 T. Materials and Methods We added a magnetization-prepared (MP) FLAIR module to a Cube 3D fast spin echo sequence and optimized the refocusing flip angle train using extended phase graph simulations, taking into account image contrast, specific absorption rate (SAR), and signal-to-noise ratio (SNR) as well as T1/T2 values of the different species of interest (WM, grey matter, lesions) at 7 T. We also effected improved preparation homogeneity at 7 T by redesigning the refocusing pulse used in the MP segments. Two sets of refocusing flip angle trains—(a) an SNR-optimal and (b) a contrast-optimal set—were derived and used to scan 7 patients with Alzheimer disease/cognitive impairment and 7 patients with multiple sclerosis. Conventional constant refocusing flip MP-FLAIR images were also acquired for comparison. Lesion SNR, contrast, and lesion count were compared between the 2 optimized and the standard FLAIR sequences. Results Whole brain coverage with 0.8 mm3 isotropic spatial resolution in ∼5-minute scan times was achieved using the optimized 3D FLAIR sequences at clinically acceptable SAR levels. The SNR efficiency of the SNR-optimal sequence was significantly better than that of conventional constant refocusing flip MP-FLAIR sequence, whereas the scan time was reduced more than 2-fold (∼5 vs >10 minutes). The contrast efficiency of the contrast-optimal sequence was comparable with that of the constant refocusing flip sequence. Lesion load ascertained by lesion counting was not significantly different among the sequences. Conclusion Magnetization-prepared FLAIR-Cube with refocusing flip angle trains optimized for SNR and contrast can be used to characterize WM and cortical lesions at 7 T with 0.8 mm3 isotropic resolution in short scan times and without SAR penalty.


  • Visualization of intra-thalamic nuclei with optimized white-matter-nulled MPRAGE at 7T

    by Thomas Tourdias, Manojkumar Saranathan, Ives R. Levesque, Jason Su, Brian K. Rutt


  • Open Access

    Variable spatiotemporal resolution three‐dimensional dixon sequence for rapid dynamic contrast‐enhanced breast MRI

    by Manojkumar Saranathan, Dan W. Rettmann, Brian A. Hargreaves, Jafi A. Lipson, Bruce L. Daniel

    Purpose: To investigate a new variable spatiotemporal resolution dynamic contrast‐enhanced (DCE) MRI method termed DIfferential Subsampling with Cartesian Ordering (DISCO), for imaging of breast cancer.Materials and Methods: DISCO combines variable density, pseudorandom k‐space segmentation and two‐point Dixon fat–water separation for high spatiotemporal resolution breast DCE MRI. During the contrast wash‐in phase, view sharing is used to achieve high temporal resolution. Forty patients referred for breast MRI were imaged, 26 using the proposed DISCO sequence and 14 using a conventional low‐spatial‐resolution dynamic sequence (VIBRANT‐FLEX) on a 3 Tesla scanner. DISCO dynamic images from 14 patients were compared with VIBRANT‐FLEX images from 14 other patients. The image quality assessed by radiologist image ranking in a blinded manner, and the temporal characteristics of the two sequences were compared.Results: A spatial resolution of 1.1 × 1.1 × 1.2 mm3 (160 slices, 28 cm field of view) was achieved with axial bilateral coverage in 120 s. Dynamic images with ∼9 s effective temporal resolution were generated during the 2‐min contrast wash‐in phase. The image quality of DISCO dynamic images ranked significantly higher than low spatial resolution VIBRANT‐FLEX images (19.5 versus 9.5, Mann‐Whitney U‐test P = 0.00914), with no significant differences in the maximum slope of aortic enhancement.Conclusion: DISCO is a promising variable‐spatiotemporal‐resolution imaging sequence for capturing the dynamics of rapidly enhancing tumors as well as structural features postcontrast. A near 1‐mm isotropic spatial resolution was achieved with postcontrast static phase images in 120 s and dynamic phase images acquired in 9 s per phase. J. Magn. Reson. Imaging 2014;40:1392–1399. © 2013 Wiley Periodicals, Inc.


  • Musculoskeletal MRI at 3.0T and 7.0T: A comparison of relaxation times and image contrast

    by Caroline D. Jordan, Manojkumar Saranathan, Neal K. Bangerter, Brian A. Hargreaves, Garry E. Gold


  • Open Access

    Three‐dimensional dixon fat–water separated rapid breathheld imaging of myocardial infarction

    by Manojkumar Saranathan, James Glockner

    Purpose: To develop a breathhold three‐dimensional (3D) Dixon technique for fat suppressed imaging of myocardial infarction.Materials and Methods: A pulse sequence was developed that uses a radial fan‐beam k‐space segmentation scheme for efficient coverage of k‐space, enabling 3D scans in a single breathhold. The sequence uses a dual‐echo bipolar readout to enable Dixon fat–water separation for improved visualization of epicardial and pericardial delayed enhancement. The 3D Dixon method was compared with a conventional 2D fast gradient recalled echo (FGRE) ‐based technique in 25 patients.Results: Pericardial visualization scores and confidence were higher while overall image quality and artifacts were slightly worse for 3D Dixon compared with 2D FGRE. Robust fat suppression was achieved in 21 of 25 cases using the 3D Dixon method.Conclusion: A 3D breathhold method for fat–water separated imaging of myocardial delayed enhancement was developed and validated. J. Magn. Reson. Imaging 2013;38:1362–1368.


  • Open Access

    Efficient bloch‐siegert B1+ mapping using spiral and echo‐planar readouts

    by Manojkumar Saranathan, Mohammad Mehdi Khalighi, Gary H. Glover, Prachi Pandit, Brian K. Rutt

    The Bloch‐Siegert (B‐S) B1+ mapping technique is a fast, phase‐based method that is highly SAR limited especially at 7T, necessitating the use of long repetition times. Spiral and echo‐planar readouts were incorporated in a gradient‐echo based B‐S sequence to reduce specific absoprtion rate (SAR) and improve its scan efficiency. A novel, numerically optimized 4 ms B‐S off‐resonant pulse at + 1960 Hz was used to increase sensitivity and further reduce SAR compared with the conventional 6 ms Fermi B‐S pulse. Using echo‐planar and spiral readouts, scan time reductions of 8–16 were achieved. By reducing the B‐S pulse width by a factor of 1.5, SAR was reduced by a factor of 1.5 and overall sensitivity was increased by a factor of 1.33 due to the nearly halved resonance offset of the new B‐S pulse. This was validated on phantoms and volunteers at 7 T. Magn Reson Med 70:1669–1673, 2013.


  • Open Access

    DIfferential subsampling with cartesian ordering (DISCO): A high spatio‐temporal resolution dixon imaging sequence for multiphasic contrast enhanced abdominal imaging

    by Manojkumar Saranathan, Dan W. Rettmann, Brian A. Hargreaves, Sharon E. Clarke, Shreyas S. Vasanawala

    Purpose: To develop and evaluate a multiphasic contrast‐enhanced MRI method called DIfferential Sub‐sampling with Cartesian Ordering (DISCO) for abdominal imaging.Materials and Methods: A three‐dimensional, variable density pseudo‐random k‐space segmentation scheme was developed and combined with a Dixon‐based fat‐water separation algorithm to generate high temporal resolution images with robust fat suppression and without compromise in spatial resolution or coverage. With institutional review board approval and informed consent, 11 consecutive patients referred for abdominal MRI at 3 Tesla (T) were imaged with both DISCO and a routine clinical three‐dimensional SPGR‐Dixon (LAVA FLEX) sequence. All images were graded by two radiologists using quality of fat suppression, severity of artifacts, and overall image quality as scoring criteria. For assessment of arterial phase capture efficiency, the number of temporal phases with angiographic phase and hepatic arterial phase was recorded.Results: There were no significant differences in quality of fat suppression, artifact severity or overall image quality between DISCO and LAVA FLEX images (P > 0.05, Wilcoxon signed rank test). The angiographic and arterial phases were captured in all 11 patients scanned using the DISCO acquisition (mean number of phases were two and three, respectively).Conclusion: DISCO effectively captures the fast dynamics of abdominal pathology such as hyperenhancing hepatic lesions with a high spatio‐temporal resolution. Typically, 1.1 × 1.5 × 3 mm spatial resolution over 60 slices was achieved with a temporal resolution of 4–5 s. J. Magn. Reson. Imaging 2012;35:1484–1492.