Annalisa De Pastina
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Annalisa De Pastina has a total of 73 co-authors. Here are the top co-authors by number of shared publications:
- Luis Guillermo Villanueva
École Polytechnique Fédérale de Lausanne (EPFL)
6 shared publications - Andreas Fuchsluger
Institute for Microelectronics and Microsensors, Johannes Kepler University Linz, Linz, Austria
3 shared publications - Bernhard Jakoby
Institute for Microelectronics and Microsensors, Johannes Kepler University Linz, Linz, Austria
3 shared publications Ernest Ting-Ta Yen
Kilby Labs, Texas Instruments Inc. 2 , 2900 Semiconductor Dr., Santa Clara, California 95051, USA
3 shared publications- Giulio Brunetti
Tissue Engineering Research Group Department of Anatomy & Regenerative Medicine, Royal College of Surgeons in Ireland (RCSI) Dublin Ireland
3 shared publications - Martin Hegner
Centre for Research on Adaptive Nanostructures and Nanodevices (CRANN)
3 shared publications
Latest Publications
- 5 August 2026
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 59 (31) , 315102
Wafer-scale integration of piezo- and ferroelectric Al 0.64 Sc 0.36 N thin films by reactive sputtering
Large-area deposition of aluminum-scandium-nitride (Al 1 −x Sc x N) thin films with higher Sc content ( x ) remains challenging due to several issues, such as abnormal orientation growth, stress control, and the undesired crystal phase. These anomalies across the wafer hinder the development of high scandium-content AlScN films, which are critical for microelectromechanical systems (MEMS) applications. In this study, we report on the sputter deposition of Al 0.64 Sc 0.36 N thin films from a 304 mm diameter Al 0.64 Sc 0.36 alloy target on 200 mm Si (100) wafers, achieving an exceptionally high deposition rate of 8.7 μ m h −1 with less than 1% abnormally oriented grains and controllable stress tuning. Comprehensive microstructural and electrical characterizations confirm the superior growth of high-quality Al 0.64 Sc 0.36 N films with exceptional wafer-averaged piezoelectric coefficients ( d 33 ,f = 15.62 pm V −1 and e 31 ,f = −2.9 C m −2 ) due to low point defects density and grain mosaicity. This is accomplished through the implementation of an optimized seed layer and a refined electrode integration strategy, along with optimal process conditions. The wafer yield and device failure rates are analyzed and correlated with the average stress of the films and their stress profiles along the diameter. The resulting films demonstrate excellent uniformity in structural, compositional, and piezoelectric properties across the entire 200 mm wafer, underscoring their strong potential for next-generation MEMS applications.
- 5 August 2026
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 59 (31) , 315102
Wafer-scale integration of piezo- and ferroelectric Al 0.64 Sc 0.36 N thin films by reactive sputtering
Large-area deposition of aluminum-scandium-nitride (Al 1 −x Sc x N) thin films with higher Sc content ( x ) remains challenging due to several issues, such as abnormal orientation growth, stress control, and the undesired crystal phase. These anomalies across the wafer hinder the development of high scandium-content AlScN films, which are critical for microelectromechanical systems (MEMS) applications. In this study, we report on the sputter deposition of Al 0.64 Sc 0.36 N thin films from a 304 mm diameter Al 0.64 Sc 0.36 alloy target on 200 mm Si (100) wafers, achieving an exceptionally high deposition rate of 8.7 μ m h −1 with less than 1% abnormally oriented grains and controllable stress tuning. Comprehensive microstructural and electrical characterizations confirm the superior growth of high-quality Al 0.64 Sc 0.36 N films with exceptional wafer-averaged piezoelectric coefficients ( d 33 ,f = 15.62 pm V −1 and e 31 ,f = −2.9 C m −2 ) due to low point defects density and grain mosaicity. This is accomplished through the implementation of an optimized seed layer and a refined electrode integration strategy, along with optimal process conditions. The wafer yield and device failure rates are analyzed and correlated with the average stress of the films and their stress profiles along the diameter. The resulting films demonstrate excellent uniformity in structural, compositional, and piezoelectric properties across the entire 200 mm wafer, underscoring their strong potential for next-generation MEMS applications.
- 15 June 2026
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 139 (23)
200 mm wafer-scale integration of bilayer wurtzite ferroelectric AlScN exhibiting effective d33,f > 26.8 pm/V and e31,f > 4.6 C/m2
We report the successful integration of a bilayer ferroelectric aluminum–scandium–nitride (Al0.64Sc0.36N) thin film on an industrial-scale 200 mm silicon (100) wafer. Microstructural analysis revealed that both the bottom and top Al0.64Sc0.36N layers exhibit comparable characteristics. Wafer-scale ferroelectric and piezoelectric characterization of the individual layers showed similar average values for permittivity (ɛ), loss tangent (tan δ), and piezoelectric coefficients (d33,f and e31,f). Findings suggest that the bottom Al0.64Sc0.36N layer has a lower leakage current than the top layer in the bilayer configuration. We present a strategy for efficiently actuating both the top and bottom layers to generate a high equivalent longitudinal strain and transverse stress without requiring any complex or additional electrical circuitry. Upon excitation, the bilayer structure yields equivalent d33,f and e31,f values of >26.8 pm/V and >4.6 C/m2, respectively, among the highest ever reported within bilayers of complementary metal–oxide–semiconductor (CMOS) compatible ferroelectric nitride thin films. Such high piezoelectric coefficients enable the broader adoption of lead-free ferroelectric materials for actuator applications.
- 15 June 2026
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 139 (23)
200 mm wafer-scale integration of bilayer wurtzite ferroelectric AlScN exhibiting effective d33,f > 26.8 pm/V and e31,f > 4.6 C/m2
We report the successful integration of a bilayer ferroelectric aluminum–scandium–nitride (Al0.64Sc0.36N) thin film on an industrial-scale 200 mm silicon (100) wafer. Microstructural analysis revealed that both the bottom and top Al0.64Sc0.36N layers exhibit comparable characteristics. Wafer-scale ferroelectric and piezoelectric characterization of the individual layers showed similar average values for permittivity (ɛ), loss tangent (tan δ), and piezoelectric coefficients (d33,f and e31,f). Findings suggest that the bottom Al0.64Sc0.36N layer has a lower leakage current than the top layer in the bilayer configuration. We present a strategy for efficiently actuating both the top and bottom layers to generate a high equivalent longitudinal strain and transverse stress without requiring any complex or additional electrical circuitry. Upon excitation, the bilayer structure yields equivalent d33,f and e31,f values of >26.8 pm/V and >4.6 C/m2, respectively, among the highest ever reported within bilayers of complementary metal–oxide–semiconductor (CMOS) compatible ferroelectric nitride thin films. Such high piezoelectric coefficients enable the broader adoption of lead-free ferroelectric materials for actuator applications.
- Open Access
- 15 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 9 (10) , 1-4
High-Performance Acoustofluidic Platform for Hematocrit Determination and Particle Separation Using Lateral Plate Transducer Modes
Acoustofluidics enables contact-free manipulation of particles in fluids using acoustic forces, making it ideal for handling biological samples without labeling or surface modification. While bulk acoustic wave (BAW) devices typically rely on transducer thickness modes, this work demonstrates high-performance particle manipulation using lateral width modes. Our silicon-glass-based microfluidic device, coupled to a piezoelectric transducer in an antisymmetric lateral mode, achieves acoustic energy densities up to $\text{3000 J/m}^{\text{3}}$—comparable to leading thickness-mode systems. This work demonstrates the two key applications, first, direct hematocrit determination by focusing red blood cells in whole blood, enabling optical analysis without centrifugation, and second, flow-through separation of particles and cells at rates up to $\text{9 mL/min}$. The efficient particle focusing and separation performance confirm that lateral transducer modes are a powerful alternative in acoustofluidics. This approach broadens the design space for lab-on-chip systems targeting label-free diagnostics and sample preparation.
- 15 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 9 (10) , 1-4
Open AccessHigh-Performance Acoustofluidic Platform for Hematocrit Determination and Particle Separation Using Lateral Plate Transducer Modes
Acoustofluidics enables contact-free manipulation of particles in fluids using acoustic forces, making it ideal for handling biological samples without labeling or surface modification. While bulk acoustic wave (BAW) devices typically rely on transducer thickness modes, this work demonstrates high-performance particle manipulation using lateral width modes. Our silicon-glass-based microfluidic device, coupled to a piezoelectric transducer in an antisymmetric lateral mode, achieves acoustic energy densities up to $\text{3000 J/m}^{\text{3}}$—comparable to leading thickness-mode systems. This work demonstrates the two key applications, first, direct hematocrit determination by focusing red blood cells in whole blood, enabling optical analysis without centrifugation, and second, flow-through separation of particles and cells at rates up to $\text{9 mL/min}$. The efficient particle focusing and separation performance confirm that lateral transducer modes are a powerful alternative in acoustofluidics. This approach broadens the design space for lab-on-chip systems targeting label-free diagnostics and sample preparation.
- Open Access
- 20 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (24) , 40274-40285
Acoustofluidic Particle Trapping in a Structured Microchannel Using Lateral Transducer Modes
By using lateral extensional modes of piezoelectric plate transducers for the actuation of a microfluidic chip containing a structured microchannel, we achieved two-dimensional single-node acoustofluidic particle trapping inside a circular cavity as well as two-dimensional multi-node trapping in straight channels. In order to manipulate the particles in two lateral dimensions, we used two separate PZT transducers attached to the bottom of the microfluidic chip, where each is responsible for generating a standing acoustic wave in a specific direction inside the microfluidic structures of the chip. We demonstrate trapping of polymer microspheres and trapping of human embryonic kidney cells with a performance that can compete with current bulk acoustic methods which typically employ transducer thickness modes. The acoustic energy density of the involved acoustic fields reaches several hundred (430) Joules per cubic meter, leading to trapping times of tenths of a second (150 ms) and nanonewton trapping forces (0.42-1.7 nN). The relatively low, sub-megahertz resonance frequency of the utilized lateral transducer mode in the cavity trapping, results in a large, millimeter long wavelength of the acoustic wave inside the fluid, which enables collection of comparably large volumina of multiple tens of nanoliter containing several thousands of particles or cells. Consequently, with the large volumes involved, it appears feasible to trap bigger objects, like multicellular organisms or organoids with approximately one millimeter in size.
- 20 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (24) , 40274-40285
Open AccessAcoustofluidic Particle Trapping in a Structured Microchannel Using Lateral Transducer Modes
By using lateral extensional modes of piezoelectric plate transducers for the actuation of a microfluidic chip containing a structured microchannel, we achieved two-dimensional single-node acoustofluidic particle trapping inside a circular cavity as well as two-dimensional multi-node trapping in straight channels. In order to manipulate the particles in two lateral dimensions, we used two separate PZT transducers attached to the bottom of the microfluidic chip, where each is responsible for generating a standing acoustic wave in a specific direction inside the microfluidic structures of the chip. We demonstrate trapping of polymer microspheres and trapping of human embryonic kidney cells with a performance that can compete with current bulk acoustic methods which typically employ transducer thickness modes. The acoustic energy density of the involved acoustic fields reaches several hundred (430) Joules per cubic meter, leading to trapping times of tenths of a second (150 ms) and nanonewton trapping forces (0.42-1.7 nN). The relatively low, sub-megahertz resonance frequency of the utilized lateral transducer mode in the cavity trapping, results in a large, millimeter long wavelength of the acoustic wave inside the fluid, which enables collection of comparably large volumina of multiple tens of nanoliter containing several thousands of particles or cells. Consequently, with the large volumes involved, it appears feasible to trap bigger objects, like multicellular organisms or organoids with approximately one millimeter in size.
- Open Access
- 18 March 2024
- Published by MDPI AG in Proceedings
- Vol. 97 (1) , 41
Concept and Proof of Principle of an Acoustofluidic Single-Particle Sorting Device Using a Spatially Confined Acoustic Active Region
We present the concept and a proof-of-principle experiment for an acoustofluidic single- particle sorter. In a microfluidic channel, a flow profile with the following three parallel fluid domains is generated: buffer fluid in the center and buffer plus particles in the lateral domains. Due to the laminar flow regime present in microfluidics, the particles essentially follow the stream line(s) along the channel. In the spatially confined sorting and detection region, by switching on the standing acoustic wave, particles of interest (POIs) are pushed into the center fluid domain, thus leaving the chip at the center outlet. For particles of non-interest (PONIs), the acoustic region remains silent, so PONIs are not centered and follow their path to the side outlet.
- 18 March 2024
- Published by MDPI AG in Proceedings
- Vol. 97 (1) , 41
Open AccessConcept and Proof of Principle of an Acoustofluidic Single-Particle Sorting Device Using a Spatially Confined Acoustic Active Region
We present the concept and a proof-of-principle experiment for an acoustofluidic single- particle sorter. In a microfluidic channel, a flow profile with the following three parallel fluid domains is generated: buffer fluid in the center and buffer plus particles in the lateral domains. Due to the laminar flow regime present in microfluidics, the particles essentially follow the stream line(s) along the channel. In the spatially confined sorting and detection region, by switching on the standing acoustic wave, particles of interest (POIs) are pushed into the center fluid domain, thus leaving the chip at the center outlet. For particles of non-interest (PONIs), the acoustic region remains silent, so PONIs are not centered and follow their path to the side outlet.
- Open Access
- 23 September 2021
- Published by Royal Society of Chemistry (RSC) in Nanoscale Advances
- Vol. 3 (24) , 6903-6911
Quantitative epitope analysis reveals drastic 63% reduced immuno-affinity and 60% enhanced transmissibility for SARS-CoV-2 variants
Quantitative analysis of SARS-CoV-2 variant-specific immunization from finger prick blood sample within minutes.
- 23 September 2021
- Published by Royal Society of Chemistry (RSC) in Nanoscale Advances
- Vol. 3 (24) , 6903-6911
Open AccessQuantitative epitope analysis reveals drastic 63% reduced immuno-affinity and 60% enhanced transmissibility for SARS-CoV-2 variants
Quantitative analysis of SARS-CoV-2 variant-specific immunization from finger prick blood sample within minutes.
- Open Access
- 1 June 2021
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 92 (6) , 065001
Multimodal real-time frequency tracking of cantilever arrays in liquid environment for biodetection: Comprehensive setup and performance analysis
We present a nanomechanical platform for real-time quantitative label-free detection of target biomolecules in a liquid environment with mass sensitivity down to few pg. Newly fabricated arrays of up to 18 cantilevers are integrated in a micromachined fluidic chamber, connected to software-controlled fluidic pumps for automated sample injections. We discuss two functionalization approaches to independently sensitize the interface of different cantilevers. A custom piezo-stack actuator and optical readout system enable the measurement of resonance frequencies up to 2 MHz. We implement a new measurement strategy based on a phase-locked loop (PLL), built via in-house developed software. The PLL allows us to track, within the same experiment, the evolution of resonance frequency over time of up to four modes for all the cantilevers in the array. With respect to the previous measurement technique, based on standard frequency sweep, the PLL enhances the estimated detection limit of the device by a factor of 7 (down to 2 pg in 5 min integration time) and the time resolution by more than threefold (below 15 s), being on par with commercial gold-standard techniques. The detection limit and noise of the new setup are investigated via Allan deviation and standard deviation analysis, considering different resonance modes and interface chemistries. As a proof-of-concept, we show the immobilization and label-free in situ detection of live bacterial cells (E. coli), demonstrating qualitative and quantitative agreement in the mechanical response of three different resonance modes.
- 1 June 2021
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 92 (6) , 065001
Open AccessMultimodal real-time frequency tracking of cantilever arrays in liquid environment for biodetection: Comprehensive setup and performance analysis
We present a nanomechanical platform for real-time quantitative label-free detection of target biomolecules in a liquid environment with mass sensitivity down to few pg. Newly fabricated arrays of up to 18 cantilevers are integrated in a micromachined fluidic chamber, connected to software-controlled fluidic pumps for automated sample injections. We discuss two functionalization approaches to independently sensitize the interface of different cantilevers. A custom piezo-stack actuator and optical readout system enable the measurement of resonance frequencies up to 2 MHz. We implement a new measurement strategy based on a phase-locked loop (PLL), built via in-house developed software. The PLL allows us to track, within the same experiment, the evolution of resonance frequency over time of up to four modes for all the cantilevers in the array. With respect to the previous measurement technique, based on standard frequency sweep, the PLL enhances the estimated detection limit of the device by a factor of 7 (down to 2 pg in 5 min integration time) and the time resolution by more than threefold (below 15 s), being on par with commercial gold-standard techniques. The detection limit and noise of the new setup are investigated via Allan deviation and standard deviation analysis, considering different resonance modes and interface chemistries. As a proof-of-concept, we show the immobilization and label-free in situ detection of live bacterial cells (E. coli), demonstrating qualitative and quantitative agreement in the mechanical response of three different resonance modes.
- Open Access
- 29 April 2021
- Published by Springer Nature in Microsystems & Nanoengineering
- Vol. 7 (1) , 1-7
Avoiding transduction-induced heating in suspended microchannel resonators using piezoelectricity
Calorimetry of single biological entities remains elusive. Suspended microchannel resonators (SMRs) offer excellent performance for real-time detection of various analytes and could hold the key to unlocking pico-calorimetry experiments. However, the typical readout techniques for SMRs are optical-based, and significant heat is dissipated in the sensor, altering the measurement and worsening the frequency noise. In this manuscript, we demonstrate for the first time full on-chip piezoelectric transduction of SMRs on which we focus a laser Doppler vibrometer to analyze its effect. We demonstrate that suddenly applying the laser to a water-filled SMR causes a resonance frequency shift, which we attribute to a local increase in temperature. When the procedure is repeated at increasing flow rates, the resonance frequency shift diminishes, indicating that convection plays an important role in cooling down the device and dissipating the heat induced by the laser. We also show that the frequency stability of the device is degraded by the laser source. In comparison to an optical readout scheme, a low-dissipative transduction method such as piezoelectricity shows greater potential to capture the thermal properties of single entities.
- 29 April 2021
- Published by Springer Nature in Microsystems & Nanoengineering
- Vol. 7 (1) , 1-7
Open AccessAvoiding transduction-induced heating in suspended microchannel resonators using piezoelectricity
Calorimetry of single biological entities remains elusive. Suspended microchannel resonators (SMRs) offer excellent performance for real-time detection of various analytes and could hold the key to unlocking pico-calorimetry experiments. However, the typical readout techniques for SMRs are optical-based, and significant heat is dissipated in the sensor, altering the measurement and worsening the frequency noise. In this manuscript, we demonstrate for the first time full on-chip piezoelectric transduction of SMRs on which we focus a laser Doppler vibrometer to analyze its effect. We demonstrate that suddenly applying the laser to a water-filled SMR causes a resonance frequency shift, which we attribute to a local increase in temperature. When the procedure is repeated at increasing flow rates, the resonance frequency shift diminishes, indicating that convection plays an important role in cooling down the device and dissipating the heat induced by the laser. We also show that the frequency stability of the device is degraded by the laser source. In comparison to an optical readout scheme, a low-dissipative transduction method such as piezoelectricity shows greater potential to capture the thermal properties of single entities.
- 21 December 2020
- Published by Royal Society of Chemistry (RSC) in Nanoscale
- Vol. 13 (4) , 2338-2349
Nanotechnological immunoassay for rapid label-free analysis of candidate malaria vaccines
Malaria is a life-threatening epidemic disease with half of the world's population at risk. Although its incidence rate has fallen since 2010, this ratio dramatically stalled between 2014 and 2018. New fast and optimized tools in vaccine analysis and seroconversion testing are critically needed. We developed a clinical diagnostic device based on piezo-actuated nanoresonators that perform as quantitative in situ calibrated nano-bio sensors for specific detection of multiple target molecules in serum samples. The immunoassay successfully diagnoses humoral immune responses induced by malaria vaccine candidates and reveals the timeline and stage of the infection. We applied the newly developed strategy to a variety of different samples, from pure antibody/vaccine solutions, to blood samples from clinical trials on both naïve and pre-exposed malaria volunteers from sub-Saharan countries. Our nanomechanical assay provides a direct one-step label-free quantitative immunoassay that is on par with the gold-standard, multi-step enzyme-linked immunosorbent assay (ELISA). We achieve a limit of detection of few pg ml−1, or sub-pM concentrations. The 6 μl sample volume allows more than 50 experiments from one finger prick. Furthermore, we simultaneously detected multiple analytes by differential functionalization of multiple sensors in parallel. The inherent differential read-out with in situ controls reduces false positive results. Due to the faster turnaround time, the minimal volume required and the automatized handling system, this technique has great potential for miniaturization and routine diagnostics in pandemic emergencies.
- 21 December 2020
- Published by Royal Society of Chemistry (RSC) in Nanoscale
- Vol. 13 (4) , 2338-2349
Nanotechnological immunoassay for rapid label-free analysis of candidate malaria vaccines
Malaria is a life-threatening epidemic disease with half of the world's population at risk. Although its incidence rate has fallen since 2010, this ratio dramatically stalled between 2014 and 2018. New fast and optimized tools in vaccine analysis and seroconversion testing are critically needed. We developed a clinical diagnostic device based on piezo-actuated nanoresonators that perform as quantitative in situ calibrated nano-bio sensors for specific detection of multiple target molecules in serum samples. The immunoassay successfully diagnoses humoral immune responses induced by malaria vaccine candidates and reveals the timeline and stage of the infection. We applied the newly developed strategy to a variety of different samples, from pure antibody/vaccine solutions, to blood samples from clinical trials on both naïve and pre-exposed malaria volunteers from sub-Saharan countries. Our nanomechanical assay provides a direct one-step label-free quantitative immunoassay that is on par with the gold-standard, multi-step enzyme-linked immunosorbent assay (ELISA). We achieve a limit of detection of few pg ml−1, or sub-pM concentrations. The 6 μl sample volume allows more than 50 experiments from one finger prick. Furthermore, we simultaneously detected multiple analytes by differential functionalization of multiple sensors in parallel. The inherent differential read-out with in situ controls reduces false positive results. Due to the faster turnaround time, the minimal volume required and the automatized handling system, this technique has great potential for miniaturization and routine diagnostics in pandemic emergencies.
- 18 February 2020
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 30 (4) , 043001
Suspended micro/nano channel resonators: a review
Micro- and nano-electromechanical systems (M/NEMS) have demonstrated outstanding sensing capabilities down to the yoctogram ( ) scale in vacuum environment and cryogenic temperatures. In order to bring such extraordinary resolution levels into the study of biological processes, suspended microchannel resonators (SMRs) have been developed. SMRs are hollow devices allowing for fluidic confinement inside the body of the resonator, which can thus be kept in dry environment or encapsulated in vacuum. Analyte binding and flow-through experiments can be performed, these latter enabling single-cell analysis. In this paper, we survey the progress of over the past 20 years in the field of SMRs. We review the main fabrication, transduction and packaging strategies. We also provide an insight into the working principle of the sensors and their applications to microfluidics and biology.
- 18 February 2020
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 30 (4) , 043001
Suspended micro/nano channel resonators: a review
Micro- and nano-electromechanical systems (M/NEMS) have demonstrated outstanding sensing capabilities down to the yoctogram ( ) scale in vacuum environment and cryogenic temperatures. In order to bring such extraordinary resolution levels into the study of biological processes, suspended microchannel resonators (SMRs) have been developed. SMRs are hollow devices allowing for fluidic confinement inside the body of the resonator, which can thus be kept in dry environment or encapsulated in vacuum. Analyte binding and flow-through experiments can be performed, these latter enabling single-cell analysis. In this paper, we survey the progress of over the past 20 years in the field of SMRs. We review the main fabrication, transduction and packaging strategies. We also provide an insight into the working principle of the sensors and their applications to microfluidics and biology.