Giulio Brunetti
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Giulio Brunetti has a total of 61 co-authors. Here are the top co-authors by number of shared publications:
- Fergal Joseph O'BRien
Royal College of Surgeons in Ireland
4 shared publications - Martin Hegner
Centre for Research on Adaptive Nanostructures and Nanodevices (CRANN)
4 shared publications - Annalisa De Pastina
Silicon Austria Labs GmbH
3 shared publications - Francesco Padovani
Institute of Functional Epigenetics, Molecular Targets and Therapeutics Center, Helmholtz Zentrum München 1 , Neuherberg
3 shared publications Chiara Rotella
School of Physics, Center for Research on Adaptive Nanostructures and Nanodevices (CRANN), Trinity College Dublin (TCD) 1 , D02 Dublin, Ireland
2 shared publications- Cian O'COnnor
Tissue Engineering Research Group, Department of Anatomy & Regenerative Medicine, Royal College of Surgeons in Ireland, Dublin, Ireland
2 shared publications
Latest Publications
- Open Access
Tailoring MXene Flake Morphology via Aerosol Jet Printing for Biological and Strain Sensor Applications
MXenes (Ti 3 C 2 T x ) are two‐dimensional (2D) layered nanomaterials typically processed as aligned flakes. However, their morphology can also be engineered into crumpled architectures with distinct physicochemical properties that remain largely unexplored. Here, Aerosol Jet Printing (AJP) is established as a scalable manufacturing strategy to tailor MXene flake morphology through precise control of the printing conditions. By repurposing the printer's built‐in alignment camera, a rapid monitoring method was developed to distinguish aligned and crumpled morphologies during fabrication. Systematic investigation of the printing parameters identified mass flow, nozzle size, and ink concentration as the key variables governing flake morphology, demonstrating its general applicability on other 2D materials, such as graphene and MoS 2 . Aligned MXene films achieved electrical conductivities of up to 2672 ± 125 S cm − 1 , whereas crumpled films exhibited increased roughness and hydrophilicity. The engineered morphologies were further validated across multiple applications, including neural interfaces, antimicrobial coatings, and strain sensors. Both morphologies supported excellent biocompatibility with primary neurons and human induced pluripotent stem cell‐derived neural cells, while crumpled MXenes enhanced antibacterial activity against Staphylococcus aureus and improved strain‐sensing performance. These findings highlight the importance of controlling the morphology of 2D materials during 3D printing, providing a scalable route toward multifunctional biomedical devices.
Open AccessTailoring MXene Flake Morphology via Aerosol Jet Printing for Biological and Strain Sensor Applications
MXenes (Ti 3 C 2 T x ) are two‐dimensional (2D) layered nanomaterials typically processed as aligned flakes. However, their morphology can also be engineered into crumpled architectures with distinct physicochemical properties that remain largely unexplored. Here, Aerosol Jet Printing (AJP) is established as a scalable manufacturing strategy to tailor MXene flake morphology through precise control of the printing conditions. By repurposing the printer's built‐in alignment camera, a rapid monitoring method was developed to distinguish aligned and crumpled morphologies during fabrication. Systematic investigation of the printing parameters identified mass flow, nozzle size, and ink concentration as the key variables governing flake morphology, demonstrating its general applicability on other 2D materials, such as graphene and MoS 2 . Aligned MXene films achieved electrical conductivities of up to 2672 ± 125 S cm − 1 , whereas crumpled films exhibited increased roughness and hydrophilicity. The engineered morphologies were further validated across multiple applications, including neural interfaces, antimicrobial coatings, and strain sensors. Both morphologies supported excellent biocompatibility with primary neurons and human induced pluripotent stem cell‐derived neural cells, while crumpled MXenes enhanced antibacterial activity against Staphylococcus aureus and improved strain‐sensing performance. These findings highlight the importance of controlling the morphology of 2D materials during 3D printing, providing a scalable route toward multifunctional biomedical devices.
- Open Access
- 1 June 2026
- Published by KEAI Publishing in Bioactive Materials
- Vol. 60, 724-743
Development of a PTEN-siRNA activated scaffold to promote axonal regrowth following spinal cord injury
This study showcases the successful development of a PTEN-siRNA activated scaffold for SCI repair applications. Initially, siRNA was combined with the novel non-viral glycosaminoglycan-binding enhanced transduction (GET) peptide vector (image of GET vector from [22]). The formulated GET-siRNA nanoparticles effectively transfected primary neurons, a cell type generally considered challenging to transfect. Subsequently, siRNA-nanoparticles were incorporated into a hyaluronic acid scaffold enriched with neurotrophic extracellular matrix proteins (collagen IV and fibronectin) developed by our laboratory for spinal cord repair applications. Functionalisation of these scaffolds with PTEN-siRNA nanoparticles significantly enhanced their capacity to promote neurite outgrowth. Image 1
- 1 June 2026
- Published by KEAI Publishing in Bioactive Materials
- Vol. 60, 724-743
Open AccessDevelopment of a PTEN-siRNA activated scaffold to promote axonal regrowth following spinal cord injury
This study showcases the successful development of a PTEN-siRNA activated scaffold for SCI repair applications. Initially, siRNA was combined with the novel non-viral glycosaminoglycan-binding enhanced transduction (GET) peptide vector (image of GET vector from [22]). The formulated GET-siRNA nanoparticles effectively transfected primary neurons, a cell type generally considered challenging to transfect. Subsequently, siRNA-nanoparticles were incorporated into a hyaluronic acid scaffold enriched with neurotrophic extracellular matrix proteins (collagen IV and fibronectin) developed by our laboratory for spinal cord repair applications. Functionalisation of these scaffolds with PTEN-siRNA nanoparticles significantly enhanced their capacity to promote neurite outgrowth. Image 1
- Open Access
- 16 April 2026
- Published by Elsevier in Journal of Tissue Viability
- Vol. 35 (3) , 101002
Sensitivity and Specificity of Sub-Epidermal Moisture (SEM) assessment in detecting localised oedema in an ex vivo porcine model
- 16 April 2026
- Published by Elsevier in Journal of Tissue Viability
- Vol. 35 (3) , 101002
Open AccessSensitivity and Specificity of Sub-Epidermal Moisture (SEM) assessment in detecting localised oedema in an ex vivo porcine model
- Open Access
- 16 January 2026
- Published by Elsevier in Acta Biomaterialia
- Vol. 212, 187-201
Laser patterning of ECM-derived biomaterials to direct degradation, site-specific resorption, controlled vascularization and functional repair of large nerve defects
- 16 January 2026
- Published by Elsevier in Acta Biomaterialia
- Vol. 212, 187-201
Open AccessLaser patterning of ECM-derived biomaterials to direct degradation, site-specific resorption, controlled vascularization and functional repair of large nerve defects
- Open Access
- 14 February 2025
- Published by Elsevier in Journal of Tissue Viability
- Vol. 34 (2) , 100871
Exploring physiological differences in injury response by skin tone: A scoping review
- 14 February 2025
- Published by Elsevier in Journal of Tissue Viability
- Vol. 34 (2) , 100871
Open AccessExploring physiological differences in injury response by skin tone: A scoping review
- Open Access
- 8 July 2023
- Published by Elsevier in Journal of Tissue Viability
- Vol. 32 (4) , 508-515
Validation of a sub-epidermal moisture scanner for early detection of pressure ulcers in an ex vivo porcine model of localized oedema
- 8 July 2023
- Published by Elsevier in Journal of Tissue Viability
- Vol. 32 (4) , 508-515
Open AccessValidation of a sub-epidermal moisture scanner for early detection of pressure ulcers in an ex vivo porcine model of localized oedema
- Open Access
- 23 September 2021
- Published by Royal Society of Chemistry (RSC) in Nanoscale Advances
- Vol. 3 (24) , 6903-6911
Quantitative epitope analysis reveals drastic 63% reduced immuno-affinity and 60% enhanced transmissibility for SARS-CoV-2 variants
Quantitative analysis of SARS-CoV-2 variant-specific immunization from finger prick blood sample within minutes.
- 23 September 2021
- Published by Royal Society of Chemistry (RSC) in Nanoscale Advances
- Vol. 3 (24) , 6903-6911
Open AccessQuantitative epitope analysis reveals drastic 63% reduced immuno-affinity and 60% enhanced transmissibility for SARS-CoV-2 variants
Quantitative analysis of SARS-CoV-2 variant-specific immunization from finger prick blood sample within minutes.
- Open Access
- 1 June 2021
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 92 (6) , 065001
Multimodal real-time frequency tracking of cantilever arrays in liquid environment for biodetection: Comprehensive setup and performance analysis
We present a nanomechanical platform for real-time quantitative label-free detection of target biomolecules in a liquid environment with mass sensitivity down to few pg. Newly fabricated arrays of up to 18 cantilevers are integrated in a micromachined fluidic chamber, connected to software-controlled fluidic pumps for automated sample injections. We discuss two functionalization approaches to independently sensitize the interface of different cantilevers. A custom piezo-stack actuator and optical readout system enable the measurement of resonance frequencies up to 2 MHz. We implement a new measurement strategy based on a phase-locked loop (PLL), built via in-house developed software. The PLL allows us to track, within the same experiment, the evolution of resonance frequency over time of up to four modes for all the cantilevers in the array. With respect to the previous measurement technique, based on standard frequency sweep, the PLL enhances the estimated detection limit of the device by a factor of 7 (down to 2 pg in 5 min integration time) and the time resolution by more than threefold (below 15 s), being on par with commercial gold-standard techniques. The detection limit and noise of the new setup are investigated via Allan deviation and standard deviation analysis, considering different resonance modes and interface chemistries. As a proof-of-concept, we show the immobilization and label-free in situ detection of live bacterial cells (E. coli), demonstrating qualitative and quantitative agreement in the mechanical response of three different resonance modes.
- 1 June 2021
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 92 (6) , 065001
Open AccessMultimodal real-time frequency tracking of cantilever arrays in liquid environment for biodetection: Comprehensive setup and performance analysis
We present a nanomechanical platform for real-time quantitative label-free detection of target biomolecules in a liquid environment with mass sensitivity down to few pg. Newly fabricated arrays of up to 18 cantilevers are integrated in a micromachined fluidic chamber, connected to software-controlled fluidic pumps for automated sample injections. We discuss two functionalization approaches to independently sensitize the interface of different cantilevers. A custom piezo-stack actuator and optical readout system enable the measurement of resonance frequencies up to 2 MHz. We implement a new measurement strategy based on a phase-locked loop (PLL), built via in-house developed software. The PLL allows us to track, within the same experiment, the evolution of resonance frequency over time of up to four modes for all the cantilevers in the array. With respect to the previous measurement technique, based on standard frequency sweep, the PLL enhances the estimated detection limit of the device by a factor of 7 (down to 2 pg in 5 min integration time) and the time resolution by more than threefold (below 15 s), being on par with commercial gold-standard techniques. The detection limit and noise of the new setup are investigated via Allan deviation and standard deviation analysis, considering different resonance modes and interface chemistries. As a proof-of-concept, we show the immobilization and label-free in situ detection of live bacterial cells (E. coli), demonstrating qualitative and quantitative agreement in the mechanical response of three different resonance modes.
- 21 December 2020
- Published by Royal Society of Chemistry (RSC) in Nanoscale
- Vol. 13 (4) , 2338-2349
Nanotechnological immunoassay for rapid label-free analysis of candidate malaria vaccines
Malaria is a life-threatening epidemic disease with half of the world's population at risk. Although its incidence rate has fallen since 2010, this ratio dramatically stalled between 2014 and 2018. New fast and optimized tools in vaccine analysis and seroconversion testing are critically needed. We developed a clinical diagnostic device based on piezo-actuated nanoresonators that perform as quantitative in situ calibrated nano-bio sensors for specific detection of multiple target molecules in serum samples. The immunoassay successfully diagnoses humoral immune responses induced by malaria vaccine candidates and reveals the timeline and stage of the infection. We applied the newly developed strategy to a variety of different samples, from pure antibody/vaccine solutions, to blood samples from clinical trials on both naïve and pre-exposed malaria volunteers from sub-Saharan countries. Our nanomechanical assay provides a direct one-step label-free quantitative immunoassay that is on par with the gold-standard, multi-step enzyme-linked immunosorbent assay (ELISA). We achieve a limit of detection of few pg ml−1, or sub-pM concentrations. The 6 μl sample volume allows more than 50 experiments from one finger prick. Furthermore, we simultaneously detected multiple analytes by differential functionalization of multiple sensors in parallel. The inherent differential read-out with in situ controls reduces false positive results. Due to the faster turnaround time, the minimal volume required and the automatized handling system, this technique has great potential for miniaturization and routine diagnostics in pandemic emergencies.
- 21 December 2020
- Published by Royal Society of Chemistry (RSC) in Nanoscale
- Vol. 13 (4) , 2338-2349
Nanotechnological immunoassay for rapid label-free analysis of candidate malaria vaccines
Malaria is a life-threatening epidemic disease with half of the world's population at risk. Although its incidence rate has fallen since 2010, this ratio dramatically stalled between 2014 and 2018. New fast and optimized tools in vaccine analysis and seroconversion testing are critically needed. We developed a clinical diagnostic device based on piezo-actuated nanoresonators that perform as quantitative in situ calibrated nano-bio sensors for specific detection of multiple target molecules in serum samples. The immunoassay successfully diagnoses humoral immune responses induced by malaria vaccine candidates and reveals the timeline and stage of the infection. We applied the newly developed strategy to a variety of different samples, from pure antibody/vaccine solutions, to blood samples from clinical trials on both naïve and pre-exposed malaria volunteers from sub-Saharan countries. Our nanomechanical assay provides a direct one-step label-free quantitative immunoassay that is on par with the gold-standard, multi-step enzyme-linked immunosorbent assay (ELISA). We achieve a limit of detection of few pg ml−1, or sub-pM concentrations. The 6 μl sample volume allows more than 50 experiments from one finger prick. Furthermore, we simultaneously detected multiple analytes by differential functionalization of multiple sensors in parallel. The inherent differential read-out with in situ controls reduces false positive results. Due to the faster turnaround time, the minimal volume required and the automatized handling system, this technique has great potential for miniaturization and routine diagnostics in pandemic emergencies.
- 18 June 2018
- Published by Royal Society of Chemistry (RSC) in Nanoscale
- Vol. 10 (26) , 12797-12804
Towards personalised rapid label free miRNA detection for cancer and liver injury diagnostics in cell lysates and blood based samples
Label free nanomechanical miRNA detection from biological samples utilising cantilever arrays in an automated diagnostic platform.
- 18 June 2018
- Published by Royal Society of Chemistry (RSC) in Nanoscale
- Vol. 10 (26) , 12797-12804
Towards personalised rapid label free miRNA detection for cancer and liver injury diagnostics in cell lysates and blood based samples
Label free nanomechanical miRNA detection from biological samples utilising cantilever arrays in an automated diagnostic platform.