MYMyonggeun Yoon

Myonggeun Yoon

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Myonggeun Yoon has a total of 14 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Radiation-Induced Cancers From Modern Radiotherapy Techniques: Intensity-Modulated Radiotherapy Versus Proton Therapy

    by Myonggeun Yoon, Sung Hwan Ahn, Jinsung Kim, Dong Ho Shin, Sung Yong Park, Se Byeong Lee, Kyung Hwan Shin, Kwan Ho Cho


  • Accuracy of an Automatic Patient-Positioning System Based on the Correlation of Two Edge Images in Radiotherapy

    by Myonggeun Yoon, Minho Cheong, Jinsung Kim, Dong Ho Shin, Sung Yong Park, Se Byeong Lee

    We have clinically evaluated the accuracy of an automatic patient-positioning system based on the image correlation of two edge images in radiotherapy. Ninety-six head & neck images from eight patients undergoing proton therapy were compared with a digitally reconstructed radiograph (DRR) of planning CT. Two edge images, a reference image and a test image, were extracted by applying a Canny edge detector algorithm to a DRR and a 2D X-ray image, respectively, of each patient before positioning. In a simulation using a humanoid phantom, performed to verify the effectiveness of the proposed method, no registration errors were observed for given ranges of rotation, pitch, and translation in the x, y, and z directions. For real patients, however, there were discrepancies between the automatic positioning method and manual positioning by physicians or technicians. Using edged head coronal- and sagittal-view images, the average differences in registration between these two methods for the x, y, and z directions were 0.11 cm, 0.09 cm and 0.11 cm, respectively, whereas the maximum discrepancies were 0.34 cm, 0.38 cm, and 0.50 cm, respectively. For rotation and pitch, the average registration errors were 0.95° and 1.00°, respectively, and the maximum errors were 3.6° and 2.3°, respectively. The proposed automatic patient-positioning system based on edge image comparison was relatively accurate for head and neck patients. However, image deformation during treatment may render the automatic method less accurate, since the test image many differ significantly from the reference image.


  • Open Access

    A new homogeneity index based on statistical analysis of the dose–volume histogram

    by Myonggeun Yoon, Sung Yong Park, Dongho Shin, Se Byeong Lee, Hong Ryull Pyo, Dae Yong Kim, Kwan Ho Cho

    The goal of the present study was to develop a new dose–volume histogram (DVH)– based homogeneity index for effectively evaluating the dose homogeneity of intensity‐modulated radiotherapy plans. The new index, called the sigma‐index (“S‐index”) is defined as the standard deviation of the normalized differential DVH curve. In a study of 16 patients with brain tumors at our institution, the S‐index was found to vary from 0.80 to 3.15. Our results showed that the S‐index provides a more reliable and accurate measure of dose homogeneity than that given by conventional methods. A guideline for evaluating the dose homogeneity of treatment plans based on the S‐index and its relation to equivalent uniform dose is discussed.PACS numbers: 87.53.Xd, 87.53.Tf