Win Tun Latt
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Win Tun Latt has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- U-Xuan Tan
School of Mechanical and Aerospace Engineering, Nanyang Technological University, Singapore
7 shared publications - Wei Tech Ang
School of Mechanical and Aerospace Engineering, Nanyang Technological University, Singapore, Singapore
7 shared publications - Cheng Yap Shee
School of Mechanical and Aerospace Engineering, Nanyang Technological University, Singapore
6 shared publications - Kalyana Chakravarthy Veluvolu
School of Electronics Engineering, Kyungpook National University, Daegu, Republic of Korea
4 shared publications C. Y. Shee
School of Mechanical and Aerospace Engineering, Nanyang Technological University, Singapore
3 shared publications- Cameron N. Riviere
Carnegie Mellon University
3 shared publications
Latest Publications
- 27 September 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 16 (4) , 773-778
A Low-Cost Flexure-Based Handheld Mechanism for Micromanipulation
With the advancement in the knowledge of surgical procedures and cell micromanipulation, there is a demand for a handheld instrument to perform micromanipulation. Hence, this paper presents a 3-DOF handheld mechanism for micromanipulation driven by three piezoelectric actuators. Flexure-based joints are utilized because of its advantages like the nonexistence of backlash and assembly errors. However, it is difficult and expensive to make such compact mechanism using traditional machining methods. In addition, the traditional machining methods are limited to simple design. To reduce the cost of fabrication and also to allow more complex designs, Objet (a rapid prototyping machine) is proposed to be used to build the mechanism. With regards to the handheld applications, the size of the mechanism is a constraint. Hence, a parallel manipulator design is the preferred choice because of its rigidity and compactness. For the illustration of an application, the mechanism is designed with an intraocular needle attached to it. Possible applications of this design include enhancement of performance in microsurgery and cell micromanipulation. Experiments are also conducted to evaluate the manipulator's tracking performance of the needle tip at a frequency of 10 Hz.
- 27 September 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 16 (4) , 773-778
A Low-Cost Flexure-Based Handheld Mechanism for Micromanipulation
With the advancement in the knowledge of surgical procedures and cell micromanipulation, there is a demand for a handheld instrument to perform micromanipulation. Hence, this paper presents a 3-DOF handheld mechanism for micromanipulation driven by three piezoelectric actuators. Flexure-based joints are utilized because of its advantages like the nonexistence of backlash and assembly errors. However, it is difficult and expensive to make such compact mechanism using traditional machining methods. In addition, the traditional machining methods are limited to simple design. To reduce the cost of fabrication and also to allow more complex designs, Objet (a rapid prototyping machine) is proposed to be used to build the mechanism. With regards to the handheld applications, the size of the mechanism is a constraint. Hence, a parallel manipulator design is the preferred choice because of its rigidity and compactness. For the illustration of an application, the mechanism is designed with an intraocular needle attached to it. Possible applications of this design include enhancement of performance in microsurgery and cell micromanipulation. Experiments are also conducted to evaluate the manipulator's tracking performance of the needle tip at a frequency of 10 Hz.
- 23 October 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 9 (12) , 1864-1871
Compact Sensing Design of a Handheld Active Tremor Compensation Instrument
Active physiological tremor compensation instruments have been under research and development recently. The sensing unit of the instruments provides information on three degrees-of-freedom (DOF) motion of the instrument tip using accelerations provided by accelerometers placed inside the instruments. A complete vector of angular acceleration of the instrument needs to be known to obtain information on three DOF motions of the tip. Sensing resolution of angular acceleration about the instrument axis is directly proportional to the width of the proximal-end sensing unit. To keep the sensing resolution high enough, the width of the unit has to be made large. As a result, the proximal-end sensing unit of the instruments is bulky. In this paper, placement of accelerometers is proposed such that the angular acceleration about the instrument axis need not be known to obtain information on the three DOF motions of the tip. With the proposed placement, the instrument is no longer bulky and fewer number of accelerometers is required, thereby making the instrument compact and better in terms of ergonomics and reliability. Experiments were conducted to show that the proposed design of placement works properly.
- 23 October 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 9 (12) , 1864-1871
Compact Sensing Design of a Handheld Active Tremor Compensation Instrument
Active physiological tremor compensation instruments have been under research and development recently. The sensing unit of the instruments provides information on three degrees-of-freedom (DOF) motion of the instrument tip using accelerations provided by accelerometers placed inside the instruments. A complete vector of angular acceleration of the instrument needs to be known to obtain information on three DOF motions of the tip. Sensing resolution of angular acceleration about the instrument axis is directly proportional to the width of the proximal-end sensing unit. To keep the sensing resolution high enough, the width of the unit has to be made large. As a result, the proximal-end sensing unit of the instruments is bulky. In this paper, placement of accelerometers is proposed such that the angular acceleration about the instrument axis need not be known to obtain information on the three DOF motions of the tip. With the proposed placement, the instrument is no longer bulky and fewer number of accelerometers is required, thereby making the instrument compact and better in terms of ergonomics and reliability. Experiments were conducted to show that the proposed design of placement works properly.
- 14 April 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 14 (5) , 598-605
Feedforward Controller of Ill-Conditioned Hysteresis Using Singularity-Free Prandtl–Ishlinskii Model
Piezoelectric, magnetostrictive, and shape memory alloy actuators are gaining importance in high-frequency precision applications constrained by space. Their intrinsic hysteretic behavior makes control difficult. The Prandtl-Ishlinskii (PI) operator can model hysteresis well, albeit a major inadequacy: the inverse operator does not exist when the hysteretic curve gradient is not positive definite, i.e., ill condition occurs when slope is negative. An inevitable tradeoff between modeling accuracy and inversion stability exists. The hysteretic modeling improves with increasing number of play operators. But as the piecewise continuous interval of each operator reduces, the model tends to be ill-conditioned, especially at the turning points. Similar ill-conditioned situation arises when these actuators move heavy loads or operate at high frequency. This paper proposes an extended PI operator to map hysteresis to a domain where inversion is well behaved. The inverse weights are then evaluated to determine the inverse hysteresis model for the feedforward controller. For illustration purpose, a piezoelectric actuator is used.
- 14 April 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 14 (5) , 598-605
Feedforward Controller of Ill-Conditioned Hysteresis Using Singularity-Free Prandtl–Ishlinskii Model
Piezoelectric, magnetostrictive, and shape memory alloy actuators are gaining importance in high-frequency precision applications constrained by space. Their intrinsic hysteretic behavior makes control difficult. The Prandtl-Ishlinskii (PI) operator can model hysteresis well, albeit a major inadequacy: the inverse operator does not exist when the hysteretic curve gradient is not positive definite, i.e., ill condition occurs when slope is negative. An inevitable tradeoff between modeling accuracy and inversion stability exists. The hysteretic modeling improves with increasing number of play operators. But as the piecewise continuous interval of each operator reduces, the model tends to be ill-conditioned, especially at the turning points. Similar ill-conditioned situation arises when these actuators move heavy loads or operate at high frequency. This paper proposes an extended PI operator to map hysteresis to a domain where inversion is well behaved. The inverse weights are then evaluated to determine the inverse hysteresis model for the feedforward controller. For illustration purpose, a piezoelectric actuator is used.
- 1 August 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2008 (1094687X) , 1952-1955
A study of a hand-held instrument's angular motion due to physiological tremor in micromanipulation tasks
Angular motion of a hand-held instrument due to physiological tremor during micromanipulation tasks was recorded with a six degree-of-freedom accelerometer-based sensing unit placed in the instrument. Methods to get angular velocities and angular accelerations from the acceleration readings of accelerators in the sensing unit are described. Statistics of angular velocity and angular acceleration of the instrument due to the tremor obtained from ten normal subjects are reported. Assumption of very small tremor angular velocities in micromanipulation tasks to calculate tremor angular accelerations analytically is validated.
- 1 August 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2008 (1094687X) , 1952-1955
A study of a hand-held instrument's angular motion due to physiological tremor in micromanipulation tasks
Angular motion of a hand-held instrument due to physiological tremor during micromanipulation tasks was recorded with a six degree-of-freedom accelerometer-based sensing unit placed in the instrument. Methods to get angular velocities and angular accelerations from the acceleration readings of accelerators in the sensing unit are described. Statistics of angular velocity and angular acceleration of the instrument due to the tremor obtained from ten normal subjects are reported. Assumption of very small tremor angular velocities in micromanipulation tasks to calculate tremor angular accelerations analytically is validated.
- 1 August 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2008 (1094687X) , 5640-5643
Design and implementation of a two degree-of-freedom micromanipulation assessment system
A two degree-of-freedom (DOF) micro motion sensing system to assess micromanipulation accuracy and physiological tremor has been developed. The system employs a position sensitive detector (PSD) module and a laser diode placed inside an instrument used in micromanipulation. A laser light is shined from the laser diode onto the PSD surface which is faced upward. The PSD detects the centroid position of the laser light spot falling onto its surface. A few markers are overlaid in a circular pattern on the PSD surface as reference for path dependent tests. Ambient light disturbance is eliminated by modulating the laser light on and off. Advantages and limitation of the system comparing to other similar systems are described.
- 1 August 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2008 (1094687X) , 5640-5643
Design and implementation of a two degree-of-freedom micromanipulation assessment system
A two degree-of-freedom (DOF) micro motion sensing system to assess micromanipulation accuracy and physiological tremor has been developed. The system employs a position sensitive detector (PSD) module and a laser diode placed inside an instrument used in micromanipulation. A laser light is shined from the laser diode onto the PSD surface which is faced upward. The PSD detects the centroid position of the laser light spot falling onto its surface. A few markers are overlaid in a circular pattern on the PSD surface as reference for path dependent tests. Ambient light disturbance is eliminated by modulating the laser light on and off. Advantages and limitation of the system comparing to other similar systems are described.
- 16 July 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 8 (8) , 1385-1388
Estimating Displacement of Periodic Motion With Inertial Sensors
Inertial sensors, like accelerometers and gyroscopes, are rarely used by themselves to measure displacement. Accuracy of inertial sensors is greatly handicapped by the notorious integration drift, which arises due to numerical integration of the sensors zero bias error. A solution is proposed in this paper to provide drift free estimation of displacement from inertial sensors.
- 16 July 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 8 (8) , 1385-1388
Estimating Displacement of Periodic Motion With Inertial Sensors
Inertial sensors, like accelerometers and gyroscopes, are rarely used by themselves to measure displacement. Accuracy of inertial sensors is greatly handicapped by the notorious integration drift, which arises due to numerical integration of the sensors zero bias error. A solution is proposed in this paper to provide drift free estimation of displacement from inertial sensors.
- 1 August 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2007 (1094687X) , 2847-2850
Bandlimited Multiple Fourier Linear Combiner for Real-time Tremor Compensation
Surgical accuracy of the hand-held instruments depends on the active compensation of disturbance and tremor. Physiological tremor is one of the main causes for imprecision in micro-surgery procedures. One of the popular tremor compensation methods is based on weighted-frequency Fourier linear combiner (WFLC) algorithm, that can adapt to the changes in frequency as well as amplitude of the tremor signal. WLFC estimates the dominant frequency and the amplitude. For the case of tremor with frequency variation or comprising of two or three frequencies close in spectral domain, the WFLC performance is degraded. In this paper, we present a bandlimited multiple Fourier linear combiner that can track the modulated signals with multiple frequency components. We also discuss the tremor sensing with accelerometers. Using the proposed algorithm the drift caused by the accelerometers is also eliminated. The proposed filter is tested in real-time for 1-DOF cancellation of tremor.
- 1 August 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2007 (1094687X) , 2847-2850
Bandlimited Multiple Fourier Linear Combiner for Real-time Tremor Compensation
Surgical accuracy of the hand-held instruments depends on the active compensation of disturbance and tremor. Physiological tremor is one of the main causes for imprecision in micro-surgery procedures. One of the popular tremor compensation methods is based on weighted-frequency Fourier linear combiner (WFLC) algorithm, that can adapt to the changes in frequency as well as amplitude of the tremor signal. WLFC estimates the dominant frequency and the amplitude. For the case of tremor with frequency variation or comprising of two or three frequencies close in spectral domain, the WFLC performance is degraded. In this paper, we present a bandlimited multiple Fourier linear combiner that can track the modulated signals with multiple frequency components. We also discuss the tremor sensing with accelerometers. Using the proposed algorithm the drift caused by the accelerometers is also eliminated. The proposed filter is tested in real-time for 1-DOF cancellation of tremor.
- 1 August 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2007 (1094687X) , 5743-5746
System to Assess Accuracy of Micromanipulation
The authors had previously developed an optical micro motion sensing system (M2S2) using a pair of orthogonally placed position sensitive detectors (PSD) to track 3D displacement of the tip of a microsurgical instrument in real-time. In the M S system, an infrared (IR) diode is used to illuminate the workspace. A ball is attached to the tip of an intraocular shaft to reflect IR rays onto the PSDs. Instrument tip position is then calculated from the centroid position of reflected IR light on the PSDs. The M2S2 system together with a test platform is used as an evaluation system to assess the accuracy and physiological tremor of subjects performing micromanipulation tasks. Since the need to use the ball at the instrument tip prevents the subjects from performing the manipulation tasks precisely, a laser light is provided as a guide for the subjects to aim at the target precisely. A laser diode module is placed inside the instrument to provide the required laser light. The instrument intraocular shaft is replaced with a same-sized hollow tube to let the laser light from the instrument pass through down to the target. The laser light spot position on the platform is used to access the performance of the subjects. The laser light spot position is calculated from the tilt angle information provided by an accelerometer placed inside the instrument, and the instrument tip position information given by M2S2.
- 1 August 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2007 (1094687X) , 5743-5746
System to Assess Accuracy of Micromanipulation
The authors had previously developed an optical micro motion sensing system (M2S2) using a pair of orthogonally placed position sensitive detectors (PSD) to track 3D displacement of the tip of a microsurgical instrument in real-time. In the M S system, an infrared (IR) diode is used to illuminate the workspace. A ball is attached to the tip of an intraocular shaft to reflect IR rays onto the PSDs. Instrument tip position is then calculated from the centroid position of reflected IR light on the PSDs. The M2S2 system together with a test platform is used as an evaluation system to assess the accuracy and physiological tremor of subjects performing micromanipulation tasks. Since the need to use the ball at the instrument tip prevents the subjects from performing the manipulation tasks precisely, a laser light is provided as a guide for the subjects to aim at the target precisely. A laser diode module is placed inside the instrument to provide the required laser light. The instrument intraocular shaft is replaced with a same-sized hollow tube to let the laser light from the instrument pass through down to the target. The laser light spot position on the platform is used to access the performance of the subjects. The laser light spot position is calculated from the tilt angle information provided by an accelerometer placed inside the instrument, and the instrument tip position information given by M2S2.
- 1 June 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 410-415
Real-Time Disturbance Compensation with Accelerometers & Piezoelectric-Driven Mechanism
Disturbance / vibration reduction is critical in many applications. One example is disk drive industry. With the advance in optical disk drive technology, the off-track or off-focusing error caused by disturbance is limiting the performance. Instead of going with the more familiar approach like vibration absorber, a real-time disturbance compensation without much phase lag is proposed. In this paper, to illustrate the idea of real-time compensation, a one dof cancellation of tremor is performed. Instantaneous motion due to the disturbance is sensed by an accelerometer inertial measurement unit (IMU). Modeling of the accelerometer is done to provide better readings. The compensation motion is provided by manipulating a piezoelectric-driven flexure-based mechanism. Due to the existence of backslash in revolute joints, flexure-based mechanism is proposed to achieve better result. Piezoelectric actuator is proposed because of its high frequency and precision. The hysteretic non-linearity of the piezoelectric actuator is modeled using Prandtl-Ishlinskii operator. Based on this model, an open-loop inverse feed-forward controller is implemented to accurately provide the required motion.
- 1 June 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 410-415
Real-Time Disturbance Compensation with Accelerometers & Piezoelectric-Driven Mechanism
Disturbance / vibration reduction is critical in many applications. One example is disk drive industry. With the advance in optical disk drive technology, the off-track or off-focusing error caused by disturbance is limiting the performance. Instead of going with the more familiar approach like vibration absorber, a real-time disturbance compensation without much phase lag is proposed. In this paper, to illustrate the idea of real-time compensation, a one dof cancellation of tremor is performed. Instantaneous motion due to the disturbance is sensed by an accelerometer inertial measurement unit (IMU). Modeling of the accelerometer is done to provide better readings. The compensation motion is provided by manipulating a piezoelectric-driven flexure-based mechanism. Due to the existence of backslash in revolute joints, flexure-based mechanism is proposed to achieve better result. Piezoelectric actuator is proposed because of its high frequency and precision. The hysteretic non-linearity of the piezoelectric actuator is modeled using Prandtl-Ishlinskii operator. Based on this model, an open-loop inverse feed-forward controller is implemented to accurately provide the required motion.
- 1 April 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10504729,p. 3383-3388
Design and Calibration of an Optical Micro Motion Sensing System for Micromanipulation Tasks
An optical sensing system has been developed using a pair of orthogonally placed position sensitive detectors (PSD) to track 3D displacement of a microsurgical instrument tip in real-time. An infrared (IR) diode is used to illuminate the workspace. A ball is attached to the tip of an intraocular shaft to reflect IR rays onto the PSDs. Instrument tip position is then calculated from the centroid positions of reflected IR light on the respective PSDs. The system can be used to assess the accuracy of hand-held microsurgical instruments and operator performance in micromanipulation tasks, such as microsurgeries. In order to eliminate inherent nonlinearity of the PSDs and lenses, calibration is performed using a feedforward neural network. After calibration, percentage RMS error is reduced from about 5.46 % to about 0.16%. The system RMS noise is about 0.7 mum. The sampling rate of the system is 250 Hz.
- 1 April 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10504729,p. 3383-3388
Design and Calibration of an Optical Micro Motion Sensing System for Micromanipulation Tasks
An optical sensing system has been developed using a pair of orthogonally placed position sensitive detectors (PSD) to track 3D displacement of a microsurgical instrument tip in real-time. An infrared (IR) diode is used to illuminate the workspace. A ball is attached to the tip of an intraocular shaft to reflect IR rays onto the PSDs. Instrument tip position is then calculated from the centroid positions of reflected IR light on the respective PSDs. The system can be used to assess the accuracy of hand-held microsurgical instruments and operator performance in micromanipulation tasks, such as microsurgeries. In order to eliminate inherent nonlinearity of the PSDs and lenses, calibration is performed using a feedforward neural network. After calibration, percentage RMS error is reduced from about 5.46 % to about 0.16%. The system RMS noise is about 0.7 mum. The sampling rate of the system is 250 Hz.